Your Position: Home > Instrumentation > Digital multimeter > AC/DC 2000A CLAMP METER FLUKE F355 FLUKE NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

AC/DC 2000A CLAMP METER FLUKE F355 FLUKE NEW

prevnext

AC/DC 2000A CLAMP METER FLUKE F355 FLUKE NEW
  • Market price: $ 3507.9
  • Shop price: $ 1063.0
  • Goods click count: 315
  • Total:
  • Quantity:
Add to cart collect
  

Description

PLCAGE: AC/DC 2000A CLAMP METER FLUKEF355 FLUKE NEW

Features:

Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dcThe large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductorsCAT IV 600 V, CAT III 1000 V rating for added user protectionIn-rush current measurement captures ‘power-on’ surge current with accuracy and repeatabilityHigh voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)Accurately measure frequency up to 1 kHz for optimum troubleshootingQuickly analyze readings using the MIN, MAX, and AVG functionsA large backlit display allows for easy visibility in low-lit areasUse the display hold feature to capture readings even when the display cannot be viewedUse the low-pass filter to smooth out noisy loads and stabilize readings

Electrical specifications

Current measurement dc and ac 10 Hz to 100 Hz

Range : 40 A

 Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 A

Range : 400 A

 Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 A

Range : 2000 A; 1400 ac rms

 Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A

 

Crest Factor (50/60 Hz)

Range : 40 A

 Crest Factor* : 2 @ 33 A, 2.4 @ 27 A

Range : 400 A

 Crest Factor* : 2 @ 330 A, 2.4 @ 270 A

Range : 2000 A; 1400 ac rms

 Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A

 

Current measurement ac 100.1 Hz to 1 kHz

Range : 40 A

 Resolution: 10 mA 
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 A

Range : 400 A

 Resolution: 100 mA 
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 A

Range : 2000 A; 1400 ac rms

 Resolution: 1 A 
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A

 

Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz 
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)

Range : 4 V

 Resolution: 1 mV 
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V

Range : 40 V

 Resolution: 10 mV 
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V

Range : 400 V

 Resolution: 100 mV 
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Range : 600 V ac rms

 Resolution: 1 V 
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Range : 1000 V dc

 Resolution: 1 V 
Accuracy: 1 % rdg + 5 digits

 

Voltage measurement (355 only) ac 100.1 Hz to 1 kHz 
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)

Range: 4 V

 Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 V

Range: 40 V

 Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 V

Range: 400 V

 Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

Range: 600 V ac rms

 Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V

 

Ohms measurement (355 only)

Range: 400 ?

 Resolution: 0.1 ?
Accuracy: 1.5 % + 5 digits

Range: 4 k?

 Resolution: 1 ?
Accuracy: 1.5 % + 5 digits

Range: 40 k?

 Resolution: 10 ?
Accuracy: 1.5 % + 5 digits

Range: 400 k?

 Resolution: 100 ?
Accuracy: 1.5 % + 5 digits

 

Continuity beeper (355 only)

 

 On at ≤ 30 ?

 

 Off at ≥ 100 ?

 

Frequency measurement

Measurement range

 5.0 Hz to 1 kHz

Resolution

 0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)

Accuracy – 5.0 Hz to 100 Hz

 0.2 % + 2 counts

Accuracy – 100.1 Hz to 1 kHz

 0.5 % + 5 counts

Trigger level

 Refer to current and voltage tables

 


*Add 2 % to error spec for CF > 2

General specifications

Batteries

 

 Six 1.5 V AA NEDA 15 A or IEC LR6

 

Battery life (with typical usage, backlight off)

 

 100 hours

 

Test leads

 

 Rated to 1000 V

 

Weight

 

 .814 kg (1.8 lb)

 

Jaw size

 

 58 mm (2.28 in)

 

Dimensions (LxWxD)

 

 300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)

 

Safety rating

 

 IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III

 

 

Environmental specifications

Operating temperature

 

 32 °F to + 122 °F (0 °C to +50 °C)

 

Storage temperature

 

 -4 °F to 140 °F (-20 °C to +60 °C)

 

Operating humidity

 

 0 to 95 % (non-condensing)

 

Operating altitude

 

 2000 m

 

Storage altitude

 

 10,000 m

 

IP rating

 

 42 (indoor use only)

 

Drop test requirements

 

 1 m

 

EMI, RFI, EMC

 

 FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325

 

Temperature coefficients

Current:

 0.1 % of reading per °C outside 22 °C to 24 °C

Voltage:

 0.1 % of reading per °C outside 22 °C to 24 °C

 

 





















  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: