No comment |
>
Instrumentation >
Digital multimeter >
AC/DC 2000A CLAMP METER FLUKE F355 FLUKE NEWPLCAGE: AC/DC 2000A CLAMP METER FLUKEF355 FLUKE NEWFeatures:
Reliably handle a wide range of high-current applications with 2000 A ac + dc true-rms, 1400 A ac, and 2000 A dcThe large 58 mm (2.3 in) jaw capacity is suitable for large or multiple conductorsCAT IV 600 V, CAT III 1000 V rating for added user protectionIn-rush current measurement captures ‘power-on’ surge current with accuracy and repeatabilityHigh voltage measurement of 1000 V ac + dc true-rms, 600 V ac, and 1000 V dc allows the user to perform multiple tests with only one tool (355 only)Resistance to 400K ohms coupled with a continuity beeper provide the convenience of a multimeter in a clamp meter. (355 only)Accurately measure frequency up to 1 kHz for optimum troubleshootingQuickly analyze readings using the MIN, MAX, and AVG functionsA large backlit display allows for easy visibility in low-lit areasUse the display hold feature to capture readings even when the display cannot be viewedUse the low-pass filter to smooth out noisy loads and stabilize readings
Electrical specifications
Current measurement dc and ac 10 Hz to 100 Hz
Range : 40 A
Resolution: 10 mA
Accuracy, A: 1.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF: 2.50 A
Trigger Level for Hz Filter ON: 0.50 ARange : 400 A
Resolution: 100 mA
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF: 2.5 A
Trigger Level for Hz Filter ON: 2.5 ARange : 2000 A; 1400 ac rms
Resolution: 1 A
Accuracy, A: 1.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF: 8 A
Trigger Level for Hz Filter ON: 8 A
Crest Factor (50/60 Hz)
Range : 40 A
Crest Factor* : 2 @ 33 A, 2.4 @ 27 A
Range : 400 A
Crest Factor* : 2 @ 330 A, 2.4 @ 270 A
Range : 2000 A; 1400 ac rms
Crest Factor* : 2 @ 1000 A, 2.4 @ 833 A
Current measurement ac 100.1 Hz to 1 kHz
Range : 40 A
Resolution: 10 mA
Accuracy > 10 A : 3.5 % rdg + 15 digits
Trigger Level for Inrush: 0.50 A
Trigger Level for Hz Filter OFF : 2.50 A
Trigger Level for Hz Filter ON : 0.50 ARange : 400 A
Resolution: 100 mA
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5.0 A
Trigger Level for Hz Filter OFF : 2.5 A
Trigger Level for Hz Filter ON : 2.5 ARange : 2000 A; 1400 ac rms
Resolution: 1 A
Accuracy > 10 A : 3.5 % rdg + 5 digits
Trigger Level for Inrush: 5 A
Trigger Level for Hz Filter OFF : 8 A
Trigger Level for Hz Filter ON : 8 A
Voltage measurement (355 only) dc and ac 10 Hz to 100 Hz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range : 4 V
Resolution: 1 mV
Accuracy: 1 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 VRange : 40 V
Resolution: 10 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 VRange : 400 V
Resolution: 100 mV
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 VRange : 600 V ac rms
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 VRange : 1000 V dc
Resolution: 1 V
Accuracy: 1 % rdg + 5 digits
Voltage measurement (355 only) ac 100.1 Hz to 1 kHz
(600 V and 1000 V ranges have 10 % over range to 660 V and 1100 V respectively.)
Range: 4 V
Resolution: 1 mV
Accuracy: 3 % rdg + 10 digits
Trigger Level for Hz Filter OFF: 0.050 V
Trigger Level for Hz Filter ON: 0.050 VRange: 40 V
Resolution: 10 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 0.25 V
Trigger Level for Hz Filter ON: 0.25 VRange: 400 V
Resolution: 100 mV
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 VRange: 600 V ac rms
Resolution: 1 V
Accuracy: 3 % rdg + 5 digits
Trigger Level for Hz Filter OFF: 6 V
Trigger Level for Hz Filter ON: 6 V
Ohms measurement (355 only)
Range: 400 ?
Resolution: 0.1 ?
Accuracy: 1.5 % + 5 digitsRange: 4 k?
Resolution: 1 ?
Accuracy: 1.5 % + 5 digitsRange: 40 k?
Resolution: 10 ?
Accuracy: 1.5 % + 5 digitsRange: 400 k?
Resolution: 100 ?
Accuracy: 1.5 % + 5 digits
Continuity beeper (355 only)
On at ≤ 30 ?
Off at ≥ 100 ?
Frequency measurement
Measurement range
5.0 Hz to 1 kHz
Resolution
0.1 Hz (15 Hz to 399.9 Hz); 1 Hz (400 Hz to 1 kHz)
Accuracy – 5.0 Hz to 100 Hz
0.2 % + 2 counts
Accuracy – 100.1 Hz to 1 kHz
0.5 % + 5 counts
Trigger level
Refer to current and voltage tables
*Add 2 % to error spec for CF > 2
General specifications
Batteries
Six 1.5 V AA NEDA 15 A or IEC LR6
Battery life (with typical usage, backlight off)
100 hours
Test leads
Rated to 1000 V
Weight
.814 kg (1.8 lb)
Jaw size
58 mm (2.28 in)
Dimensions (LxWxD)
300 mm x 98 mm x 52 mm (12 in x 3.75 in x 2 in)
Safety rating
IEC 61010-2-032, 600 V CAT IV, 1000 V CAT III
Environmental specifications
Operating temperature
32 °F to + 122 °F (0 °C to +50 °C)
Storage temperature
-4 °F to 140 °F (-20 °C to +60 °C)
Operating humidity
0 to 95 % (non-condensing)
Operating altitude
2000 m
Storage altitude
10,000 m
IP rating
42 (indoor use only)
Drop test requirements
1 m
EMI, RFI, EMC
FCC part 15, IEC/EN 61326-1:1997 class B, IEC/EN 61326:1997 3V/m, performance criteria B, EN61325
Temperature coefficients
Current:
0.1 % of reading per °C outside 22 °C to 24 °C
Voltage:
0.1 % of reading per °C outside 22 °C to 24 °C
No comment |