PLCAGE: Clamp meter 40/600/1000A FLUKE319 FLUKE New
Description
Fluke 319 is a high performance multi-functional digital clamp meter,
electrical engineer based on the most commonly used functions
Clamp design requirements, tailored for Chinese users. Fluke 319
Digital Clamp Meter provides higher accuracy of current measurement,
AC increased from 1.9% to 1.5%; DC from 2.5% to 1.5%, the precise 40A
small-scale high accuracy current test-0.01A resolution,1.6% in
high-precision measurement of degree. Engineers measure small currents
occasions to be more than the measurement of large currents.
Features:
40A unique small-scale, high accuracy current test - 0.01A resolution,
high-precision measurement of 1.6%
Clamp slim, lightweight body, more suitable for easy use in confined spaces
Large backlit display for easy reading in dark environments
Starting current function, can be measured and lighting equipment such as motor starting current
Current frequency measurement
Digital clamp meter accuracy better than 0.01A and 0.1V
1000A AC / DC current measurement
600V AC / DC voltage measurement
4000ohmresistance measurement
Digital clamp meter off sensitive measurement
Automatic shut-off feature maximizes battery life, so you can work when needed instrument
Display Hold function, the measurement results remain on the screen
One year warranty
Specifications:
AC Current range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% +/- 6 characters (50-60 Hz) 40 A
2.5% +/- 8 characters (60-500 Hz) 40 A
1.5% +/- 5 words (50-60 Hz) 600/1000 A
2.5% +/- 5 digit (60-500 Hz) 600/1000 A
Crest Factor and 2% to specifications
CF> 2 3.0 Max @ 500 A, 2.5 Max @ 600 A, 1.4 Max @ 1000 A
RMS AC response
DC Current Range 40.00 A, 600.0 A, 1000 A
Resolution 0.01 A, 0.1 A, 1 A
Accuracy 1.6% +/- 6 words (40 A)
1.5% +/- 5 words (600/1000 A)
AC voltage range 600.0 V
Resolution 0.1 V
Accuracy 1.5% +/- 5 words (20-500Hz)
AC response effectively direct
600.0 V DC voltage range
Resolution 0.1 V
Accuracy 1% +/- 4 words
Resolution Range 400.0 ohm/ 4000 ohm
Resolution 0.1 ohm/ 1 ohm
Accuracy 1% +/- 5 words
Off measurement </= 30 ohm
Starting current response time 100 ms
Frequency measurement
Range 5.0 - 500.0 Hz
Accuracy 0.5% +/- 5 words
Trigger Level 10 - 100 Hz >/= 5 A, 5 - 10 Hz, 100 - 500 Hz >/= 10 A