No comment |
PLCAGE: Thermometers FLUKEF566 FLUKE NEWFeatures:
Measure -40 C to 650 C/-40 F to 1202 FEasily access advanced features with the soft-key buttons and graphical displayMeasure smaller objects from further away, with a distance-to-spot ratio of 30:1Compatibility with all standard miniconnector K-type thermocouples allows you to preserve your thermocouple investmentsConfidently measure a wide variety of surfaces with the adjustable emissivity feature, including a built-in material tableCapture up to 20 points of data for downloading and recalling laterConfidently troubleshoot equipment with 1 % measurement accuracyVersatile interface with six languages from which to chooseTwo-year warrantyIncludes:
Thermocouple K Bead ProbeDurable Hard Case2 AA BatteriesGetting Started guide in six languagesUser’s Manual on CD in six languages (English, Spanish, French, German, Portuguese, and Simplified Chinese)
Product specifications
Infrared temperature range
566:
-40 C to 650 C (-40 F to 1202 F)
Infrared accuracy
< 0 C (32 F): (1.0 C ( 2.0 F) + 0.1/1 C or F);
> 0 C (32 F): 1 % or 1.0 C ( 2.0 F), whichever is greater
Display resolution
0.1 C / 0.1 F
Infrared spectral response
8 m to 14 m
Infrared response time
< 500 msec
Thermocouple Type-K input temperature range
-270 C to 1372 C (-454 F to 2501 F)
Thermocouple Type-K input accuracy
-270C to -40C:
(1 C + 0.2 /1 C) (-454 F to -40 F: (2 F + 0.2 /1 F))
-40C to 1372C:
1 % or 1 C (-40 F to 2501 F: 1 % or 2 F), whichever is greater
D:S (distance to measurement spot size)
566:
30:1
568:
50:1
Laser sighting
Single-point laser < 1 mw output Class 2 (II) operation, 630 nm to 670 nm
Minimum spot size
19 mm (0.75 in)
Emissivity adjustment
By built-in table of common materials or digitally adjustable from 0.10 to 1.00 by 0.01
Data storage with Date/Time stamp
566:
20 points
PC Interface and cable
566:
None
Hi/Low alarms
Audible and two-color visual
Min/Max/Avg/Dif
Yes
Display
Dot matrix 98 x 96 pixels with function menus
Backlight
Two levels, normal and extra bright for darker environments
Trigger lock
Yes
Switchable Celsius and Fahrenheit
Yes
Power
566:
2 AA/LR6 Batteries
Battery life
If used continuously:
laser and backlight on,12 hours; laser and backlight off, 100 hours
Operating temperature
0 C to 50 C (32 F to 122 F)
Storage temperature
-20 C to 60 C (-40 F to 140 F)
Bead thermocouple Type-K range
-40 C to 260 C (-40 F to 500 F)
Bead thermocouple Type-K accuracy
1.1 C (2.0 F) from 0 C to 260 C (32 F to 500 F), typically within 1.1 C (2.0 F) from -40 C to 0 C (-40 F to 32 F)
No comment |