No comment |
Process multimeter VICTOR79
Meansuring function
Range
Measuring range
Resolving power
Accuracy
Remark
DC Voltage
4V
-4.000V~4.000V
1mV
0.2%+4
Input impedance?10MΩ
40V
-40.00V~40.00V
0.01V
0.2%+4
400V
-400.0V~400.0V
0.1V
0.2%+4
AC Voltage
400mV
0~400.0mV
0.1mV
1%+4
Input impedance?10MΩ
<100pF
4V
0~4.000V
1mV
0.5%+4
40V
0~40.00V
0.011V
0.5%+4
400V
0~400.0V
0.1V
0.5%+4
DC Mv Voltage
40mV
-40.00mV~40.00mV
0.01mV
0.2%+4
Input impedance?10MΩ
400mV
-400.0mV~400.0mV
0.1mV
0.2%+4
OHM
400Ω
0~400.0Ω
0.1Ω
0.2%+4
Plough voltage?0.4V
Not including the accuracy of down-lead resistance
4kΩ
0~4.000kΩ
1Ω
0.2%+4
40kΩ
0~40.00kΩ
0.01kΩ
0.2%+4
400kΩ
0~400.0kΩ
0.1kΩ
0.2%+4
4MΩ
0~4.000MΩ
1kΩ
0.2%+4
40MΩ
0~40.00MΩ
0.01MΩ
1%+4
DC Current
40mA
-40.00mA~40.00mA
0.01mA
0.2%+4
Input impedance?1Ω
400mA
-400.00mA~400.00mA
0.1mA
0.2%+4
AC Current
40mA
0~40.00mA
0.01mA
0.5%+4