Your Position: Home > Control System > VFD > Mitsubishi VFD > Inverter FR-E720-11KW New in box

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

Inverter FR-E720-11KW New in box

prevnext

Inverter FR-E720-11KW New in box
  • Market price: $ 6933.3
  • Shop price: $ 2101.0
  • Goods click count: 293
  • Total:
  • Quantity:
Add to cart collect
  

Description

Mitsubishi Inverter FR-E720-11KW New in box

Mitsubishi Inverter FR-E720-15KW

Type FR-E720-…K(-C)  8 

0.1 

0.2 

0.4 

0.75 

1.5 

2.2 

3.7 

5.5 

7.5 

11 

15 

Applicable motor capacity (kW)  1 

0.1 

0.2 

0.4 

0.75 

1.5 

2.2 

3.7 

5.5 

7.5 

11 

15 

Output 

Rated capacity (kVA)  2 

0.3 

0.6 

1.2 

2.0 

3.2 

4.4 

7.0 

9.5 

13.1 

18.7 

23.9 

Rated current (A)  6 

0.8 (0.8) 

1.5 (1.4) 

3 (2.5) 

5 (4.1) 

8 (7) 

11 (10) 

17.5 (16.5) 

24 (23) 

33 (31) 

47 (44) 

60 (57) 

Overload current rating  3 

 

150% 60s, 200% 3s (inverse time characteristics) 

 

 

Voltage  4 

 

Three-phase 200 to 240V 

 

 

Power supply 

Rated input AC (DC) voltage/frequency 

 

Three-phase 200 to 240V 50Hz/60Hz (283 to 339VDC  7) 

 

 

Permissible AC (DC) voltage fluctuation 

 

170 to 264V 50Hz/60Hz (240 to 373VDC  7) 

 

 

Permissible frequency fluctuation 

 

±5% 

 

 

Power supply capacity (kVA)  5 

0.4 

0.8 

1.5 

2.5 

4.5 

5.5 

12 

17 

20 

28 

Protective structure (JEM1030) 

 

Enclosed type (IP20). IP40 for totally enclosed structure series. 

 

 

Cooling system 

 

Self-cooling 

Forced air cooling 

 

 

Approximate mass (kg) 

0.5 

0.5 

0.7 

1.0 

1.4 

1.4 

1.7 

4.3 

4.3 

9.0 

9.0 

 

 

 

 1 The applicable motor capacity indicated is the maximum capacity applicable for use of the Mitsubishi 4-pole standard motor.

 2 The rated output capacity indicated assumes that the output voltage is 230V.

 3 The % value of the overload current rating indicated is the ratio of the overload current to the inverter's rated output current. For repeated duty, allow time for the inverter and motor to return to or below the temperatures under 100% load.

 4 The maximum output voltage does not exceed the power supply voltage. The maximum output voltage can be changed within the setting range. However, the pulse voltage value of the inverter output side voltage remains unchanged at about that of the power supply.

 5 The power supply capacity varies with the value of the power supply side inverter impedance (including those of the input reactor and cables).

 6 Setting 2kHz or more in Pr. 72 PWM frequency selection to perform low acoustic noise operation in the ambient temperature exceeding 40°C (totally-enclosed structure is 30°C), the rated output current is the value in parenthesis.

 7 Connect DC power supply to terminal P/+ and N/-. Connect the plus side of the power supply to terminal P/+ and minus side to terminal N/-. Since the voltage between P/+ and N/- may increase due to the regeneration energy from the motor and exceeds 415V temporarily, select the DC power supply which can withstand the voltage/energy during regeneration. If using the power supply which can not withstand voltage/energy during regeneration,insert diodes in series for reverse current prevention. Although the FR-E700 series has the built-in inrush current limit circuit, select the DC power supply considering the inrush current at powering on as the inrush current four times of the rated inverter flows at powering on. Since the power supply capacity depends on the output impedance of the power, select the power supply capacity which has enough allowance according to the AC power supply system capacity.

 8 Totally enclosed structure series ends with -C.

  