No comment |
>
Control System >
VFD >
TECO VFD >
3-Phase 440V 450A 220KW 300HP TECO Inverter A510-4300-H3 NEW
Model List
Inverter model
(Model for
standard
products)
Voltage(Vac)
Horse Power
(HP)
Applied Motor
(KW)
Filter Built-in
With
without
A510-2001-H
1ph/3ph,
200~240V
+10%/-15%
50/60Hz
1
0.75
O
A510-2002-H
2
1.5
O
A510-2003-H
3
2.2
O
A510-2005-H3
3ph, 200~240V
+10%/-15%
50/60Hz
5
3.7
O
A510-2008-H3
7.5
5.5
O
A510-2010-H3
10
7.5
O
A510-2015-H3
15
11
O
A510-2020-H3
20
15
O
A510-2025-H3
25
18.5
O
A510-2030-H3
30
22
O
A510-2040-H3
40
30
O
A510-2050-H3
50
37
O
A510-2060-H3
60
45
O
A510-2075-H3
75
55
O
A510-2100-H3
100
75
O
A510-2150-H3
150
112
O
A510-4001-H3F
3ph, 380~480V
+10%/-15%
50/60Hz
1
0.75
O
A510-4001-H3
1
0.75
O
A510-4002-H3F
2
1.5
O
A510-4002-H3
2
1.5
O
A510-4008-H3
7.5
5.5
O
A510-4003-H3
3
2.2
O
A510-4005-H3
5
3.7
O
A510-4008-H3F
7.5
5.5
O
A510-4010-H3
10
7.5
O
A510-4015-H3
15
11
O
A510-4020-H3
20
15
O
A510-4025-H3
25
18.5
O
A510-4030-H3
30
22
O
A510-4030-H3F
30
22
O
A510-4040-H3
40
30
O
A510-4050-H3
50
37
O
A510-4060-H3
60
45
O
A510-4075-H3
75
55
O
A510-4100-H3
100
75
O
A510-4125-H3
125
94
O
A510-4150-H3
150
112
O
A510-4175-H3
175
130
O
A510-4215-H3
215
160
O
A510-4250-H3
250
185
O
A510-4300-H3
300
220
O
A510-4375-H3
375
280
O
A510-4425-H3
425
315
O
Environment
The environment will directly affect the proper operation and the life span of the inverter. To ensure that the inverter will give maximum service life, please comply with the following environmental conditions:
Protection
Protection Class
IP20/NEMA 1, IP00
Operating
Temperature
Ambient Temperature: (-10°C - +40°C (14 -104 °F)
Without Cover: -10°C - +50°C (14-122 °F)
If several inverters are placed in the same control panel, provide a heat
removal means to maintain ambient temperatures below 40°C
Storage
Temperature
-20°C - +70°C (-4 -158 °F)
Humidity:
95% non-condensing
Relative humidity 5% to 95%, free of moisture.
(Follow IEC60068-2-78 standard)
Altitude:
< 1000m (3,281 ft.)
Installation Site:
Avoid exposure to rain or moisture.
Avoid direct sunlight
Avoid oil mist and salinity
Avoid corrosive liquid and gas.
Avoid corrosive liquid and gas.
Avoid dust, lint fibers, and small metal filings.
Keep away from radioactive and flammable materials.
Avoid electromagnetic interference (soldering machines, power machines).
Avoid vibration (stamping, punching machines etc.).
Add a vibration-proof pad if the situation cannot be avoided.
Shock
Maximum acceleration: 1.2G (12m/s²), from 49.84 to 150 Hz
Displacement amplitude : 0.3mm (peak value), from 10 to 49.84 Hz
(Follow IEC60068-2-6 standard)
Installation