No comment |
>
Control System >
VFD >
INVT VFD >
Single-phase 230V 0.4KW 6.5A Input GD10-0R4G-S2-B INVT Inverter NEWBrief introduction of Goodrive 10 inverters
Goodrive 10 Series min-economy inverters are designed for the small power OEM application marker. With the function of vectorization V/F control and PID function, multi-step speed, DC braking and Modbus communication and so on, the inverter has more advantages but occupied less installation space.
Features
1. V/F control
2. Natural cooling (for the applications with cotton and dust)
3. Mini structure, less installation space
Rated Specifications
Model
Output power (kw)
Input current (A)
Output Current (A)
Single-phase 230V
GD10-0R2G-S2-B
0.2
4.9
1.6
GD10-0R4G-S2-B
0.4
6.5
2.5
GD10-0R7G-S2-B
0.75
9.3
4.2
GD10-1R5G-S2-B
1.5
15.7
7.5
GD10-2R2G-S2-B
2.2
24
11
Three-phase 230V
GD10-0R2G-2-B
0.2
1.9
1.6
GD10-0R4G-2-B
0.4
2.7
2.5
GD10-0R7G-2-B
0.75
4.9
4.2
GD10-1R5G-2-B
1.5
9
7.5
GD10-2R2G-2-B
2.2
15
11
Three-phase 400V
GD10-0R7G-4-B
0.75
3.2
2.5
GD10-1R5G-4-B
1.5
4.3
4.2
GD10-2R2G-4-B
2.2
7.1
5.5
Technical Specifications
Function
Specifications
Input voltage (V)
230V: input voltage range: single phase or three phase 230V 10%
400V; input voltage range: three phase 400V 15%
Input frequency (Hz)
50Hz or 60Hz Allowed range: 47~63Hz
Output voltage (V)
Equal to input voltage with the deviation of less than 5%
Output frequency(Hz)
50Hz/60Hz, Fluctuation range: 5%
Control mode
V/f control
Maximum output frequency
200Hz
Adjustable-speed ratio
0.111111111
Overload capability
150% of rated current: 1 minute
Analog input resolution
<=20mV
Digital input resolution
<=2ms
Analog input/output
Input 1.0~10V or 0-20mA, output; 1.0~10V or 0~20mA
Digital input/output
5 channels digital input, 1 Y terminal output and 1 programmable relay output
Communication
MODBUS
Mountable mode
Wall mounting
Temperature of the running environment
-10~500C, derate above 400C
Cooling
Single/three-phase 230V 0.2-0.75kW natural cooling
Single/three-phase 230V 1.5-2.2kw, three-phase 400V 0.75-2.2kw
Fault protections
Over current, overvoltage, under voltage, over temperature, overload and other protections
Braking unit
Only standard for GD10-B
Applications
Packaging machinery, food machinery, textile machinery, centrifuge, engraving machine, and cutting machine, etc
Dimensions
Wiring