No comment |
>
Control System >
VFD >
INVT VFD >
3-phase 380V 2.2KW 5.8A Input GD100-2R2G-4 INVT Inverter NEW
Brief Introduction
Goodrive 100 series inverters are compact high-performance type products in the universal market. Applying V/F and sensorless vector control mode, separately air-duct design, book structure, brand-new design platform, and built-in C3 input filter, the products enhance its performance to meet the complicated and rugged environment.
Product Features
1. More Accurate Motor Autotuning
2. Excellent Performance
3. Separate Air-duct
4. C3 input filter (standard configuration) and C2 filter (optional)
Power Ratings
Model NO.
Output Power
(kw)
Input Current (A)
Output Current (A)
Carrier Frequency (kHz)
GD100-0R7G-4
0.75
3.4
2.5
2~15(8)
GD100-1R5G-4
1.5
5.0
3.7
2~15(8)
GD100-2R2G-4
2.2
5.8
5
2~15(8)
GD100-004G-4
4
13.5
9.5
2~15(8)
GD100-5R5G-4
5.5
19.5
14
2~15(8)
GD100-7R5G-4
7.5
25
18.5
2~15(8)
GD100-011G-4
11
32
25
2~15(8)
GD100-015G-4
15
40
32
2~8(4)
Remarks
1. The input current is tested when no reactor and 380V input voltage
2. The output current is defined as the rated value when the output voltage is 380V. The output current needs to be calculated when the output voltage is 400V, 415V or 440V.
Product Specifications
Function
Specification
Power input
Input voltage (V)
AC 3PH 400V±15%
Input current (A)
Refer to the rated value
Input frequency (Hz)
50Hz or 60Hz Allowed range: 47~63Hz
Power
output
Output voltage (V)
0~input voltage
Output current (A)
Refer to the rated value
Output power (kW)
Refer to the rated value
Output frequency (Hz)
0~400Hz
Technical
control
feature
Control mode
V/F, sensorless vector control
Motor type
Asynchronous motor
Adjustable-speed ratio
Asynchronous motor 1:100 (SVC)
Speed control accuracy
+-0.2% (sensorless vector control)
Speed fluctuation
+- 0.3% (sensorless vector control)
Torque response
<20ms (sensorless vector control)
Torque control accuracy
10%(sensorless vector control)
Starting torque
0.25Hz/150%(sensorless vector control)
Overload capability
150% of rated current: 1 minute
Running
control
feature
Frequency setting
method
Digital setting, analog setting, pulse frequency setting, multi-stage speed running setting, simple PLC setting, PID setting, MODBUS communication setting
Realize the shifting between the set combination and set channel.
Auto-adjustment of the
voltage
Keep a stable voltage automatically when the grid voltage
transients
Fault protection
Provide over 30 fault protection functions: over current,
Over voltage, under voltage, overheating, phase loss and
overload, etc.
Restart after rotating
speed tracking
Realize the smooth starting of the rotating motor
Peripheral
interface
Terminal analog input
resolution
Not above 20mV
Terminal switch input
resolution
Not above 2ms
Analog input
1 channels (AI2) 0~10V/0~20mA and 1 channel (AI3) -
10~10V
Analog output
2 channels (AO1, AO2) 0~10V /0~20mA
Digital input
4 channels common input, the Max. frequency: 1kHz,
internal impedance:3.3kΩ;
1 channel high speed input, the Max. frequency: 50kHz
Relay output
2 channels programmable relay output
RO1A NO, RO1B NC, RO1C common terminal
RO2A NO, RO2B NC, RO2C common terminal
Contactor capability: 3A/AC250V
Others
Mountable method
Wall mountable and flange mountable
Temperature of the
running environment
-10~500C, derate above 400C
Average non-fault time
2 years (250C ambient temperature)
Protective degree
IP20
Cooling
Cooling
Braking unit
Embedded
EMC filter
Built-in C3 filter: meet the degree requirement of
IEC61800-3 C3
External filter:meet the degree requirement of IEC61800-3
C2
Wiring
No comment |