Your Position: Home > Control System > VFD > FUJI VFD > 400V Three-phase 960A 500KW FRN500F1S-4C FUJI FRENIC-VP Inverter

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

400V Three-phase 960A 500KW FRN500F1S-4C FUJI FRENIC-VP Inverter

prevnext

400V Three-phase 960A 500KW FRN500F1S-4C FUJI FRENIC-VP Inverter
  • Market price: $ 115150.2
  • Shop price: $ 34894.0
  • Goods click count: 481
  • Total:
  • Quantity:
Add to cart collect
  

Description

400V Three-phase 960A 500KW FRN500F1S-4C FUJI FRENIC-VP Inverter

Features

1. The effect of energy saving has updated again.

2. Simple structure, convenient manufacturing.

3. Durable design-10 years using life.

4. Fit with the HVAC (Hole Ventilator Air conditioner).

5. The design is fully considering the ambient and controlled board.

6. Easy operating

Standard Specifications

Three-phase 400V Series

3.7~55KW

Item

Specifications

Type(FRNxxxF1S-4Cxxx)

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Nominal applied motor [KW]

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Output ratings

Rated capacity[KVA]

6.8

9.5

12

17

22

28

33

44

54

64

77

Rated voltage[V]

Three-phase 380 to 480V(with AVR)

Rated Current[A]

9.0

12.5

16.5

23

30

37

44

59

72

85

105

Rated Overload capability

120% for 1min

Rated frequency[Hz]

50,60Hz

Input Rating

Rated current[A]

With DCR

7.5

10.6

14.4

21.1

28.8

 

35.5

42.2

57.0

68.5

83.2

102

 

Without DCR

13.0

17.3

23.2

33.0

43.8

52.3

60.6

77.9

94.3

114

140

Required power supply capacity[KVA]

With DCR

5.3

7.4

10

15

20

25

30

40

48

58

71

Braking

Torque[%]

20

10 to 15

DC injection braking

Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%

DC reactor (DCR)

Optional

Applicable safety standards

UL508C, C22.2No.14, EN50178: 1997

Enclosure (IEC60529)

IP20 (IEC60529) closed type, UL open type

IP00 open type, UL open type

Cooling method

Fan cooling

Weight/Mass[kg]

3.4

3.4

5.8

6.0

6.9

9.4

9.9

11.5

23

24

33

7.5~560KW

Item

Specifications

Type(FRNxxxF1S-4Cxxx)

75

90

110

132

160

200

220

280

315

355

400

450

500

560

Nominal applied motor [KW]

75

90

110

132

160

200

220

280

315

355

400

450

500

560

Output ratings

Rated capacity[KVA]

105

128

154

182

221

274

316

396

445

495

563

640

731

792

Rated voltage[V]

Three-phase 380 to 480V(with AVR)

 

 

 

Rated Current[A]

139

168

203

240

290

360

415

520

585

650

740

840

960

1040

Rated Overload capability

120% for 1min

Rated frequency[Hz]

50,60Hz

Input Rating

Rated current[A]

With DCR

138

164

201

238

286

 

357

390

500

559

628

705

 

789

881

990

Without DCR

--

--

--

--

--

--

--

--

--

--

--

--

--

--

Required power supply capacity[KVA]

With DCR

96

114

140

165

199

248

271

347

388

435

489

547

611

686

Braking

Torque[%]

10 to 15

DC injection braking

Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 60%

DC reactor (DCR)

Standard

Applicable safety standards

UL508C, C22.2No.14, EN50178: 1997(applying)

Enclosure (IEC60529)

IP00 open type, UL open type

Cooling method

Fan cooling

Weight/Mass[kg]

34

42

45

63

67

96

98

162

165

282

286

355

360

360

 

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: