No comment |
>
Control System >
VFD >
FUJI VFD >
FRN22LM1S-4C Inverter 380V22kw Elevator DedicatedFRN22LM1S-4C FUJIFILM Inverter 380V22kw Elevator DedicatedFuji / the FUJI inverter the FRENIC-Lift Elevator special inverter
Most suitable for the passenger elevator uses specially designed.
With high performance over a load capacity of 200%-10s, the current response rate is five times the original UD series.
The standard IM / of PMSM inverter can drive asynchronous traction machine can also be controlled synchronous traction machine.
Corresponding to a variety of PG pulse signal reception. Standard +12 V / +15 V the A / B, / Z, optional option card 5V line driver. Option card also corresponds to the HEIDENHAIN HeidenHainEndat2.1, 4-bit GRAY Gray code; three U, V, W encoder. The FRN ? ? ? L1MS-? ? Three-phase 400V: 5.5 ~ 30kW
? Power and model
? Rated input AC voltage
Input voltage level
Capacity
AC input voltage
Three-phase 400V
5.5kW ~ 30kW
380V ~ 480V 50/60Hz
? allow fluctuations in input power
Voltage: +10% to -15%
Frequency: +5% to -5%
Voltage unbalance: less than 2% (IEC61800-3 (5.2.3) as a standard)
? capacity range
Three-phase 400V: 5.5 ~ 30kW
? Output frequency range
Lift (L1): 01 ~ 120Hz
? Product Specifications
Rated overload current
200% of rated output current-10s
Rated frequency
50,60 Hz
Braking time
30S
Brake duty (% ED)
50
Acceleration, deceleration time
0.01 ~ 99.99s variable
Frequency setting signal
DC0 ~ +-10V (DC0 ~ +-5V) terminal 12, V2, Road
DC4 to 20mA terminals C1 all the way
Function
Forced to stop, the S-curve range, multi-step speed command is set at the same time, digital input and output logic negated start, soft start, speed regulator feedforward compensation, vibration suppression viewer, digital and analog torque bias, the password function, no crawling run, battery operation, the magnetic pole position since learning
Protection function
Over-current, short circuit protection, ground fault protection, overvoltage protection, input phase protection, output shortage protection, electronic thermal relay, PTC thermistors, overload, over-speed protection EN circuit abnormalities, PG encoder disconnection instantaneous power failure protection
Safety compliance
Depicted in the EN50178: 1997
Protection structure (IEC60529)
IP20 closed 5.5 ~ 22kW
Cooling method
Fan cooling (5.5 ~ 22kW 3-phase 400V)
No comment |