Your Position: Home > Control System > VFD > FUJI VFD > FRN110P11S-4CX Inverter 110kw P11 Series Dedicated Fan Pump

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

FRN110P11S-4CX Inverter 110kw P11 Series Dedicated Fan Pump

prevnext

FRN110P11S-4CX Inverter 110kw P11 Series Dedicated Fan Pump
  • Market price: $ 26535.3
  • Shop price: $ 8041.0
  • Goods click count: 333
  • Total:
  • Quantity:
Add to cart collect
  

Description

FRN110P11S-4CX FUJIFILM Inverter 110kw P11 Series Dedicated Fan Pump

Features:
• fan, pump and other quadratic decreasing torque dedicated inverter.
• with automatic energy saving function, to achieve energy-saving operation.
• Standard equipped with a dialogue touch panel, easy to operate.
Main elements:
Power and model
? Rated input AC voltage
Input voltage level
Capacity
AC input voltage
Three-phase 200V
22kW following
200V ~ 230V 50/60Hz
30kW more than
200V ~ 220V/50Hz 200V ~ 230V/50Hz 200V ~ 230V/60Hz
Three-phase 400V
22kW following
380V ~ 480V 50/60Hz
30kW more than
380V ~ 440V/50Hz 380V ~ 480V/60Hz
? allow fluctuations in input power
Voltage: +10% to -15%
Frequency: +5% to -5%
Voltage unbalance: less than 2% (IEC61800-3 (5.2.3) as a standard)
? capacity range
Three-phase 200V: 5.5 ~ 110kW
Three-phase 400V: 5.5 ~ 500kW
? Output frequency range
P11S: 0.1 ~ 120Hz
? Product Specifications
Rated overload current
200% 0.5 seconds, 150% 1 minute
Braking torque
Regenerative braking
5 ~ 2% 100% 150% 3% ED (0.75kw below) ED (1.5 ~ 7.5kw) by about 20% (11 ~ 22kw) about 10% ~ 15% (30kw above)
DC braking
Braking start frequency 0.1 ~ 60Hz (variable) brake braking time ~ 30s (variable) current 0 ~ 100% (P11,: 0 ~ 80%) (variable)
Acceleration, deceleration time
0.01 ~ 3600s (can be individually set acceleration and deceleration, step 4)
Multi-step speed operation
Step 16
Frequency setting signal
0 to ± 5Vdc, 0 ~~ ± 10Vdc, 4 20mAdc
Protection function
Stall prevention, overcurrent, instantaneous power failure undervoltage, overvoltage, inverter overheating, external alarm (external thermal relay), motor overload (electronic thermal relay), abnormal communication, CPU error, memory abnormalities, short circuit, to short circuit, fuse short circuit, input phase loss protection, output phase loss protection
Abnormal output contacts
1c contact
Protection structures
Completely closed from the cold type [IP40] (0.75kw below) totally enclosed forced air cooling type [IP40 fan section, except (1.5 ~ 22kw) forced air cooling type [IP00] (30kw) 30kw more than closed [IP20] is optional pieces

 


  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: