FRN110F1S-4C Inverter 110kw FRENIC-VP Fan And Pump TypeFRN110F1S-4C FUJIFILM Inverter 110kw FRENIC-VP Fan And Pump TypeWith functions suitable for HVAC use
? frequency / frequency switching
Loaded via an external timing corresponding to the power frequency inverter / inverter switching the power frequency starter.The built-in power frequency operation of the switching timing: the timing of Fuji standard and inverter alarm automatically power frequency switching timing of two kinds.
? reproduced complete PID control function
Operating temperature, pressure, flow control PID regulator attached to the "low water stop", "deviation alarm · absolute value of the alarm output".Red anti-reset the end of the function by preventing PID control, PID output limiter, integral to maintain / reset signal, making it easier adjustment of the PID control function.
? instant power failure at the start
To restore power after instantaneous power failure, automatic restart.You can choose to start from the frequency of instantaneous power failure occurs and from 0Hz starting on.Instantaneous power failure occurs, you can also choose to use the energy of the movement of the load inertia to reduce the frequency and continue operation mode.
? Can the inverter remote / panel control mode switch
Set 2 1 / frequency setting by switching frequency operation · stop instruction / operation stop command as well as local operation (operation panel operation), not only can switch the operation instructions, frequency of instruction, you can also switch between remote / panel control.
? can achieve a variety of frequency setting
Can be used in conjunction with the frequency setting signal, and select the most appropriate frequency setting method.Operation panel operation ↑ ↓ keys, analog input (4-20mA, 0 - +5 V, 0 - +10 V +1- +5 V, the forward / reverse action), multi-step frequency and step 8 (0-7 paragraph) locateda given, the UP / DOWN and communications.
? motor idling process to introduce
Even in the case of natural convection as a result of motor idling, through the detection of the operating frequency, a smooth start.
? The lower limit to implement sleep function
In the lower limit of the minimum operating speed of the fan · water pumps, etc. attached to the following limits for the following stop, stop function as a low-water use.And promote energy
? the reproduced Automatic energy saving operation function
Addition to loss of motor control in the smallest outside to control the inverter loss to a minimum, so as fans, pumps used to achieve further power saving
? power monitoring can be achieved
Using the operation panel and a variety of communications, can be a simple power monitoring (power loss, the cumulative power display, power application, etc.)
? cooling fan ON / OFF control function
Motor to stop the process, you can stop the inverter cooling fan, so you can reduce the operating noise of the fan and achieve energy efficiency.Environmental protection
? DC reactor built-in standard (recently listed) quasi-series
Will suppress high harmonic for the purpose of Option DC reactor and inverter body can be set to one structure, so you can select this series, as high harmonic rejection countermeasures policy.(Below 75KW <scheduled>)
? All models, built-in surge rejection circuit
All models are equipped with surge restrain the circuit, and therefore can reduce the cost of the electromagnetic switch and other ancillary equipment.
? EMC filter built-in quasi-standard series (recently listed) in line with European EMC standards
Full compliance with European EMC Directive.(15KW <scheduled)
? All models standard with control power auxiliary input terminal
To ensure that the inverter control power supply to ensure the normal operation in the commercial power switch when the switch automatically.Easy to maintain, protect fully functional
? determine the main circuit capacitor life
Can confirm that the ratio of the capacitor initial value, so you can guide the replacement time of the main circuit capacitor.
? loaded long-life cooling fan
Cooling fan for long life (design life: 7 years <5.5KW>) 4.5 years (7.5-30KW) Ambient temperature: 40 degrees, reducing the replacement.
? cumulative operation time of the recording and display
Record and display the running time of the motor, inverter operation time (circuit board capacitor run time, the cumulative operating time of the cooling fan running time), to facilitate the maintenance of equipment and frequency converter.
? The main circuit electrolytic capacitors and printed board, long-life
Long-life products in a variety of capacitors as life parts.The life expectancy of 10 years, the ambient temperature of 40 degrees, the load rate of 80% (Inverter rated current basis)
? Life Prediction of signal can be output transistors
Output in the main circuit capacitor, electrolytic capacitor of the printing substrate "or" cooling fan "of any one life is about to expire.
? up to save the past four alarm record
You can confirm the last four alarm.
? input / output phase loss protection function
Can start and the lack of input and output circuits in the process of running protection.
? with ground fault protection
For the ground caused by the over-current protection, to stop the inverter output.
? You can use the PTC thermistor for motor protection
Can make use of the electronic thermal relay for motor protection PTC thermistor can also be used to protect the motor.Simple operation, wiring
? Standard equipped with remote operation of the operation panel
The use of remote operation with an extension cable (optional), remote operation simple.With a function code of the copy function, you can easily copy the data to multiple inverters.
? Quick installation capabilities
Inverter drive fans, pumps, at least 19 must be set to function code, and display settings.
? Multi-function operator panel
Equipped with a backlight LCD, simple operation who Nuns through dialogue, and also qualified for quick installation features 19 function code append and delete.Global response to
? product standards in line with the EC (CE mark), UL standards and Canadian standards (cUL certification) (Application)
The standard product meets the standards of Europe and North America / Canada (pending), aimed at a unified domestic installations, equipment specifications.
? You can switch the source / drain
Ontology internal DIP switch can simply switch the digital input terminal input and output mode (source / drain)
? network corresponding to the (recent listing)
Loading option card can be mapped to DeviceNet, Profibus DP to the network on Lonworks, Mudbus Plus, CC-LINK variety of open-ended bus.RS485 communication (Modbus RTU) standard equipped with a port (shared) and the operator panel.Can be set up by an additional RS485 communication card (optional) (terminal mode), the two ports.To save space
? can be horizontal without gaps (side by side installation)
Installed inside an electrical panel, the place the space can be reduced (5.5KW below the ambient temperature of 40 degrees or less)Comprehensive options
? available in the inverter (optional support for loading software, listed in the near future)
Equipped with function code settings can simply inverter load software for data management and other Windows interface (Option) (recently listed).
? You can also remotely operated
The use of remote operation with an extension cable option, and can facilitate remote operation.
? copy of the function code function
The multi-function operator panel option (recently listed) and the operation panel mounted on the body are built-in copy function, so no separate function is set, you can simple copy the data for the inverter.
? external cooling ancillary equipment
External cooling subsidiary community use for this in vitro cooling of the inverter (30KW following options, the recent listing standard with 37KW above) can be easily installed into the distribution panel.