400V Three-phase 210A 110KW FRN110G1S-4C FUJI FRENIC-MEGA Inverter

prevnext

400V Three-phase 210A 110KW FRN110G1S-4C FUJI FRENIC-MEGA Inverter
  • Market price: $ 23951.4
  • Shop price: $ 7258.0
  • Goods click count: 317
  • Total:
  • Quantity:
Add to cart collect
  

Description

400V Three-phase 210A 110KW FRN110G1S-4C FUJI FRENIC-MEGA Inverter

 

Introduction

FRENIC-MEGA is a high performance, multifunctional inverter. Fuji Electric has developed by gathering the best of its technologies. With our own state-of-the-art technology, the control performance has evolved to a new dimension.

FRENIC-MEGA has been developed to use with a variety of equipment by improving the basic performance, meeting the requirements for various application, achieving lower maintenance, and enhancing the resistance to the environmental impacts.

FRENIC-MEGA, the inverter with the highest performance in the industry, is about to redefine the common sense of general-purpose inverters.

Standard Specifications (Basic type)

Three-phase 400V Series

(0.4 to 55kw) HD (high duty) spec for heavy load

Item

Specifications

Type(FRNxxxG1S-4x)

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Nominal applied motor [KW]

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

18.5

22

30

37

45

55

Output ratings

Rated capacity[KVA]

1.1

1.9

2.8

4.1

6.8

10

14

18

24

29

34

45

57

69

85

Rated voltage[V]

Three-phase 380 to 480V(with AVR)

Rated Current[A]

1.5

2.5

4

5.5

9

13.5

18.5

24.5

32

39

45

60

75

91

112

Overload capability

150% for 1min, 200% for 3.0S

Rated frequency[Hz]

50,60Hz

Input Ratings

Main circuit power Phases, voltage, frequency

Three-phase 380 to 480V, 50/60Hz

Auxiliary control power input Phases, voltage, frequency

--

Single-phase 380 to 480V, 50/60Hz

Auxiliary power input for fan Phases, voltage, frequency

--

Voltage, frequency variations

Voltage: (10 to -15% (Voltage unbalance: 2% or less) Frequency: +5 to -5%

Rated current[A]

With DCR

0.85

1.6

3.0

4.5

 

7.5

10.6

14.4

21.1

28.8

35.5

 

42.2

57.0

68.5

83.2

102

Without DCR

1.7

3.1

5.9

8.2

13.0

17.3

23.2

33

43.8

52.3

60.6

77.9

94.3

114

140

Required power supply capacity[KVA]

With DCR

0.6

1.2

2.1

3.2

5.2

7.4

10

15

20

25

30

40

48

58

71

Braking

Torque[%]

150%

100%

20%

10 to 15%

Braking transistor

Built-in

--

Min. ohmic value[ohm]

Torque[%]

200

180%

160

180%

96

180%

64

180%

48

180%

32

180%

24

180%

16

180%

--

Built-in braking resistance

720ohm

470ohm

160ohm

80ohm

--

 

Braking time[s]

5s

--

%ED

5

3

5

3

2

3

2

--

DC injection braking

Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100%

DC reactor (DCR)

Optional

Applicable safety standards

UL508C, C22.2No.14, EN50178: 1997

Enclosure (IEC60529)

IP20 (IEC60529) closed type, UL open type (UL 50)

IP00 open type, UL open type

Cooling method

Natural cooling

Fan cooling

Weight/Mass[kg]

1.7

2

2.6

2.7

3

6.5

6.5

5.8

9.5

9.5

10

25

26

31

33

                   

(75 to 630KW) HD (High Duty) spec for heavy load

Item

Specifications

Type(FRNxxxG1S-4x)

75

90

11

132

160

200

220

280

315

355

400

500

630

Nominal applied motor[KW]

75

90

110

132

160

200

220

280

315

355

400

500

630

Output ratings

Rated capacity [KVA]

114

134

160

192

231

287

316

396

445

495

563

731

891

Rated voltage[V]

Three-phase 380 to 480V (with AVR)

Rated Current(A)

150

176

210

253

304

377

415

520

585

650

740

960

1170

Overload capacity

150% for 1 min, 200% for 3.0s

Rated frequency [Hz]

50,60Hz

Input Ratings

Main circuit power Phase, voltage, frequency

Three-phase 380 to 480V, 50Hz

Three-phase 380 to 480V, 60Hz

Auxiliary control power input Phases, voltage, frequency

Single-phase 380 to 480V, 50/60Hz

Auxiliary power input for fan Phases, voltage, frequency

Single-phase 380 to 440V, 50Hz

Single-phase 380 to 480V, 60Hz

Voltage, frequency variations

Voltage: +10 to -15% (Voltage unbalance: 2% or less  Frequency: +5 to -5%

Rated current[A]

With DCR

138

164

210

238

286

357

390

500

559

628

705

881

1115

Without DCR

--

--

--

--

--

--

--

--

--

--

--

--

--

Required power supply capacity[kva]

With DCR

96

114

140

165

199

248

271

347

388

436

489

611

773

Braking

Torque[%]

10 to 15%

Braking transistor

--

Min. ohmic value[ohm]

Torque[%]

--

DC injection braking

Starting frequency: 0.0 to 60.0Hz, Braking time: 0.0 to 30.0s, Braking level: 0 to 100%

DC reactor (DCR)

Standard accessory

Applicable safety standards

UL508C, C22.0No.14, EN50178: 1997

Enclosure(IEC60529)

IP20 (IEC60529) closed type, UL open type (UL 50)

Cooling method

Fan cooling

Weight

42

62

64

103

103

144

144

 

 

 

 

 

 

 

Wiring

 

 

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: