No comment |
>
Control System >
VFD >
Delta VFD >
Delta Inverter VFD drive VFD300VL43B-J 3Phase 380V 30KW 40HP 0~600Hz Injection molding machineVFD300VL43B-JVFD-VJ
Features
The Delta Hybrid Servo Drive VFD-VJ Series is designed with AC servo technology to drive hydraulic systems with perfect control of the drive, motor and hydraulic unit.
Specifications
?Field Oriented Control
?Suitable for both synchronous servo motors and asynchronous servo motors
?Built-in brake unit (up to 22kW)
?RS-485 communication interface (RJ-45) and standard MODBUS communication protocol
?Precise current detection for system protection with safety ensured
?New software for PC connection allows real time monitoring of AC motor drive status
Product Specifications
230V Class
Frame
C
D
E2
Model: VFD-_ _VL_ _A-J
055
075
110
150
185
220
300
370
Power (KW)
5.5
7.5
11
15
18.5
22
30
37
Horse Power (HP)
7.5
10
15
20
25
30
40
50
Output
Output Current for
Continuous Operation
Over 60 sec (A)
33
46
62
90
119
119
180
248
Output Current for
Continuous Operation
Over 20 sec (A)
37
54
70
106
140
140
204
292
Power
Supply
Input Current (A)
25
31
47
60
80
90
106
126
Tolerable Input
Voltage Variation
Three-phase 200~240V 50/60Hz
Tolerable Supply
Voltage Variation
10% (180~264V)
Tolerable Supply
Frequency Variation
5% (47~63Hz)
Weight (kg)
8
10
10
13
13
13
36
36
460V Class
Frame
C
D
E1
E2
Model: VFD-_ _VL_ _A-J
055
075
110
150
185
220
300
370
450
550
750
Power (KW)
5.5
7.5
11
15
18.5
22
30
37
45
55
75
Horse Power (HP)
7.5
10
15
20
25
30
40
50
60
75
100
Output
Output Current for
Continuous Operation
Over 60 sec (A)
21
27
36
46
58
62
102
124
155
187
255
Output Current for
Continuous Operation
Over 20 sec (A)
25
32
42
54
68
78
120
146
182
220
300
Power
Supply
Input Current (A)
14
18
24
31
39
47
56
67
87
101
122
Tolerable Input
Voltage Variation
Three-phase 380~480V, 50/60Hz
Tolerable Supply
Voltage Variation
10% (342~528V)
Tolerable Supply
Frequency Variation
5% (47~63Hz)
Weight (kg)
8
10
10
13
13
13
36
36
36
50
50
Common Features
Control method
SVPWM
Speed Detector
Resolver / Incremental Encoder
Speed Command Input
DC 0~10V, 3-point calibration of analog input is supported
Pressure Command Input
DC 0~10V, 3-point calibration of analog input is supported
Pressure Feedback Input
DC 0~10V
General Purpose Input Signal
5 ch DC24V 8mA
General Purpose Output Signal
2 ch DC24V 50mA, 1 ch Relay output
Analog Output Voltage
1 ch dc 0~10V
Optional
Peripheral
Accessories
Speed Feedback
PG Card
Mandatory (Refer to Appendix A-5)
Braking Resistor
Mandatory (Refer to Appendix A-1)
Pressure Sensor
Mandatory (It must has an output signal ranging within 0~10V, which can be configured by Parameters 03-10~03-11; The maximum pressure can be configured by Parameter 00-08)
EMI Filter
Optional (Refer to Appendix A-7)
Protection
Feature
Motor Protection
Electronic thermal relay protection
Over Current
Protection
Over current protection is activated at 300% of the rated current
Ground Leakage
Current Protection
Activated when the leakage current is higher than 50% of the drive’s rated current
Voltage Protection
Over Voltage Level: Vdc>400/800 V; Low Voltage Level: Vdc<200/400 V
Input Power Supply
Over Voltage
Protection
Metal Oxide Varistor (MOV)
Over Temperature
Protection
Built-in temperature sensor
Environment
Protection Level
NEMA 1/IP20
Operation
Temperature
-10°C~45°C
Storage Temperature
-20°C~60°C
Humidity
Below 90% RH (non-condensing)
Vibration
1.0G below 20Hz, 0,6G at 20~60 Hz
Cooling System
Forced air cooling
Installation Altitude
Altitude below 1,000m, keep from corrosive gasses, liquid and dust
Dimensions
Wiring
No comment |