No comment |
>
Control System >
VFD >
Delta VFD >
Delta Inverter VFD drive VFD150V43A-2 3Phase 380V 15KW 20HP 0~600Hz CNC &Lifting machineVFD150V43A-2
Features
This series adopts FOC (Field Oriented Control) which is a far more precise vector control algorithm. It can be used in both speed control and position control similar to a servo motor drive. The multi-function I/O terminal is expanded to meet users' various application needs. In addition, it is supplied with a Windows based PC software program for managing parameters and dynamic monitoring. It provides an excellent solution for load regulation. It can output 150% of rated torque at zero speed, and it can have "point to point" and relative distance control functions for position control, making it the best choice for challenging industrial control applications.
Specifications
?Output frequency: 0~600Hz
?4 points adjustable V/F curve, Sensorless Vector Control, Field-Oriented Control
?Position/Speed/Torque control mode
?Sensorless Vector Control 150% torque at 0.5Hz
?150% holding torque with speed feedback
?Overload : 150% for 1 minute and 200% for 2 seconds
?Rotational/Static Auto-tuning for the motor parameters and Auto-tuning for load inertia
?Excellence torque limit in all 4 quadrants of operation
?Dual RS-485 ports, Fieldbus and PC software tools for applications
Applications
Power transmission equipment, elevator, crane, CNC tooling machines, extrusion machines, injection molding machines, and auto-storage and retrieval systems.
Standard Specifications
230V Class
Voltage Class
230V Class
Model Number VFD-XXXV
007
015
022
037
055
075
110
150
185
220
300
370
Max. Applicable Motor Output
(kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
Max. Applicable Motor Output (hp)
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
Output Rating
Rated Output Capacity (kVA)
1.9
2.7
4.2
6.5
9.5
13
19
25
29
34
46
55
Rated Output Current for
Constant Torque (A)
5.0
7.5
11
17
25
33
49
65
75
90
120
146
Rated Output Current for
Variable Torque (A)
6.25
9.4
13
21
31
41
61
81
93
112
150
182
Maximum Output Voltage (V)
3-Phase Proportional to Input Voltage
Output Frequency (Hz)
0.00~600.00 Hz
Carrier Frequency (kHz)
15
9
6
Rated Input Current (A)
6.4
9.9
15
21
25
33
52
63
68
79
106
126
Rated Voltage/Frequency
3-phase 200-240V, 50/60Hz
Voltage Tolerance
10%(180~264 V)
Frequency Tolerance
5%(47~63 Hz)
Cooling Method
Natural
Fan Cooled
Weight (kg)
2.7
3.2
4.5
6.8
8
10
13
13
13
13
36
36
460V Class
Voltage Class
460V Class
Model Number VFD-XXXV
007
015
022
037
055
075
110
150
185
220
300
370
450
550
750
Max. Applicable Motor Output
(kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
Max. Applicable Motor Output
(hp)
1.0
2.0
3.0
5.0
7.5
10
15
20
25
30
40
50
60
75
100
Output Rating
Rated Output Capacity (kVA)
2.3
3.2
4.2
6.3
9.9
14
18
24
29
34
46
56
69
80
100
Rated Output Current for
Constant Torque (A)
3.0
4.2
6.0
8.5
13
18
24
32
38
45
60
73
91
110
150
Rated Output Current for
Variable Torque (A)
3.8
5.3
7.5
10
16
22
30
40
47
56
75
91
113
138
188
Maximum Output Voltage (V)
3-phase Proportional to Input Voltage
Output Frequency (Hz)
0.00~600.00 Hz
Carrier Frequency (kHz)
15
9
6
Input Rating
Rated Input Current (A)
3-phase 380~480V
4.0
5.8
7.4
9.9
12
17
25
27
35
42
56
67
87
101
122
Rated Voltage
3-phase 380 to 480 V
Voltage Tolerance
10%(342~528 V)
Frequency Tolerance
5%(47~63 Hz)
Cooling Method
Natural
Fan Cooled
Weight (kg)
2.7
3.2
4.5
6.8
8
10
13
13
13
13
36
36
36
50
50
General Specifications
Control Characteristics
Control System
1 V/f curve; 2 V/f+PG; 3 SVC; 4 FOC+PG; 5 TQR+PG
Start Torque
Starting torque is 150% at 0.5Hz and 0Hz with FOC + PG control mode
Speed Control Range
1:100 Sensorless vector (up to 1:1000 when using PG card)
Speed Control Resolution
0.5% Sensorless vector (up to ± 0.02% when using PG card)
Speed Response Ability
5Hz (up to 30Hz for vector control)
Max. Output Frequency
0.00 to 600.00Hz
Output Frequency Accuracy
Digital command0.005%, analog command 0.5%
Frequency Setting
Resolution
Digital command0.01Hz, analog command: 1/4096(12-bit) of the max. output
frequency
Torque Limit
Max. is 200% torque current
Torque Accuracy
5%
Accel/Decel Time
0.00 to 600.00/0.0 to 6000.0 seconds
V/f Curve
Adjustable V/f curve using 4 independent points and square curve
Frequency Setting Signal
10V, 4~20mA, pulse input
Brake Torque
About 20%
Motor Protection
Electronic thermal relay protection
Over-current Protection
The current forces 220% of the over-current protection and 300% of the rated current
Ground Leakage Current
Protection
Higher than 50% X rated current
Overload Ability
Constant torque: 150% for 60 seconds, variable torque: 200% for 3 seconds
Over-voltage Protection
Over-voltage level: Vdc > 400/800V; low-voltage level: Vdc < 200/400V
Over-voltage Protection for the Input Power
Varistor (MOV)
Over-temperature Protection
Built-in temperature sensor
Compensation for the Momentory Power Loss
Up to 5 seconds for parameter setting
Protection Level
NEMA 1/IP21
Operation Temperature
-10 to 40
Storage Temperature
-20 to 60
Ambient Humidity
Below 90% RH (non-condensing)
Vibration
9.80665m/s2 (1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz
Installation Location
Altitude 1,000 m or lower, keep from corrosive gasses, liquid and dust
Dimensions
Basic wiring Diagram
No comment |