No comment |
>
Control System >
VFD >
Delta VFD >
Delta Inverter VFD drive VFD055CH43A-21 3Phase 380V 5.5kW 7.5HP 0~600Hz Lifting &EscalatorVFD055CH43A-21
Features
Using new drive technology, Delta presents you with its next generation CH2000 Series AC Motor Drive. Providing high performance with robust design the CH2000 is equipped with a larger starting torque and high overload capability to fulfill the needs of heavy load and impact loading applications.
Specifications
Super Heavy Load (SHD)
-Overload ability: rated current of 150% up to 60 seconds, 200% up to 3 seconds
-Starting torque: above 200% at 0.5Hz in normal conditions, up to 200% at 0Hz in FOC+PG mode
-Output frequency: 0.00~600.00Hz (for model above 90kW: 0.00~400Hz)
-Induction motor and synchronous motor control
-Built-in PLC program capacity: 10K steps
-Noise reduction
Production Specifications
230V Series
Frame Size
A
B
C
Model VFDxxxCH23A-21
007
015
022
037
055
075
110
150
185
Applicable Motor Output (kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
Applicable Motor Output (hp)
1
2
3
5
7.5
10
15
20
25
Output
Rating
Super Heavy Duty
Rated Output capacity(kVA)
2.0
3.2
4.4
6.8
10
13
20
26
30
Rated Output
Current (A)
5
8
11
17
25
33
49
65
75
Carrier Frequency
(kHz)
5~15kHz
Overload Tolerance
Rated output current is 150 % for 60 seconds; 200% for 3 seconds
Input Rating
Input Current (A)
Super Heavy Duty
6.4
12
16
20
28
36
52
72
83
Rated Voltage/Frequency
3-phase AC 200V~240V (-15% ~ +10%), 50/60Hz
Operating Voltage Range
170~265Vac
Frequency Tolerance
47~63Hz
AC Drive Weight
2.6± 0.3Kg
5.4± 1Kg
9.8± 1.5Kg
Cooling method
Natural Cooling
Fan cooling
Braking Chopper
Frame A to C (built-in); Frame D and above (optional)
DC reactor
Frame A to C (optional); Frame D and above (built-in)
EMI Filter
Optional
EMC-COP01
Optional
Frame Size
D
E
F
Model VFDxxxCH23A-21
200
300
370
450
550
750
Applicable Motor Output (kW)
22
22
30
37
45
55
Applicable Motor Output (hp)
30
40
50
60
75
100
Output Rating
Super Heavy DUTY
Rate Output
Capacity (kVA)
36
48
58
72
86
102
Rated Output
Current (A)
90
120
146
180
215
255
Carrier Frequency
(kHz)
5~15kHz
Overload Tolerance
Rated output current is 150 % for 60 seconds;
200% for 3 seconds
Input Rating
Input Current (A)
93
124
143
171
206
245
Rated Voltage/Frequency
3-phase AC 200V~240V (-15% ~ +10%), 50/60Hz
Operating Voltage Range
170~265Vac
Frequency Tolerance
47~63Hz
AC Drive Weight
38.5+- 1.5Kg
64.8± 1.5Kg
86.5±
1.5Kg
Cooling method
Fan Cooling
Braking Chopper
Frame A to C (built-in);
Frame D and above (optional)
DC reactor
Frame A to C (optional);
Frame D and above (built-in)
EMI Filter
Optional
EMC-COP01
Optional
460V Series
Frame Size
A
B
C
Model
VFDxxxCH43A-21
VFDxxxCH4EA-21
007
015
022
037
055
075
110
150
185
220
300
Applicable Motor Output (kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
Applicable Motor Output (hp)
1
2
3
5
7.5
10
15
20
25
30
40
Output Rating
Super Heavy
Duty
Rate Output
Capacity (kVA)
2.4
3.2
4.8
7.2
9.6
14
19
25
30
36
48
Rated Output
Current (A)
3.0
40.
6.0
9.0
12
18
24
32
38
45
60
Carrier Frequency
(kHz)
5~15kHz
Overload
Tolerance
Rated output current is 150 % for 60 seconds; 200% for 3 seconds
Input Rating
Input Current (A)
Normal Duty
4.3
5.9
8.7
14
17
20
26
35
40
47
63
Rated Voltage/Frequency
3-Phase AC 380V~480V ( -15%~+10%), 50/60Hz
Operating Voltage Range
323~528Vac
Frequency Tolerance
47~63Hz
AC Drive Weight
2.6± 0.3Kg
5.4± 1Kg
9.8± 2Kg
Cooling method
Natural
cooling
Fan cooling
Braking Chopper
Frame A to C (built-in); Frame D and above (optional)
DC reactor
Frame A to C (optional); Frame D and above (built-in)
EMI Filter
Frame A ~ C, VFDxxxxCH4EA-21, EMI filter built-in
Frame A ~ C, VFDxxxxCH43A-21, No EMI filter
EMC-COP01
Optional
Frame Size
D
E
F
G
H
Model
VFDxxxxCH43A-xx
VFD2800CH43C-00/-21
370
450
550
750
900
1100
1320
1600
1850
2200
2800
Applicable Motor Output (kW)
37
45
55
75
90
110
132
160
185
220
280
Applicable Motor Output (hp)
50
60
75
100
125
150
175
215
250
300
375
Output Rating
Super Heavy DUTY
Rate Output
Capacity (kVA)
58
73
88
120
143
175
207
247
295
359
438
Rated Output
Current (A)
73
91
110
150
180
220
250
310
370
450
550
Carrier Frequency
(kHz)
5~15kHz
4~10kHz
Overload Tolerance
Rated output current is 150 % for 60 seconds; 200% for 3 seconds
Input Rating
Input Current (A)
Normal Duty
74
101
114
157
167
207
240
300
380
400
494
Rated Voltage/Frequency
3-Phase AC 380V~480V ( -15%~+10%), 50/60Hz
Operating Voltage Range
323~528Vac
Frequency Tolerance
47~63Hz
AC Drive Weight
38.5± 1.5Kg
64.8± 1.5Kg
86.5±
1.5Kg
134± 4Kg
228Kg
Cooling method
Fan cooling
Braking Chopper
Frame D and above (optional)
DC reactor
Frame D and above (built-in)
EMI Filter
Frame D and above (optional)
EMC-COP01
Optional
Applications
Crane, processing machinery, printing machinery.
Wiring
No comment |