Features
General Purpose AC Micro Drive. Delta Electronics most cost effective general purpose drive. The VFD-S series drive is famous for its low-noise carrier frequency feature and easy to use keypad.
Specifications
?Output frequency 1.0 ~ 400 Hz
?Adjustable V/f curve
?Carrier frequency up to 10 kHz
?Built-in PID feedback control
?Built-in MODBUS communication, baud rate up to 38400 bps
?Momentary power failure or fault restart
?Built-in Sleep / Revival function
?Support communication module (DN-02, LN-01, PD-01)
Applications
Air conditioner for large buildings; water supply system for large buildings; temperature control of middle/large oven; webbing loom; packing machine; conveyer belt; fan of drying machine, etc.
General Specifications
Control Characteristics
Control System
SPWM (Sinusoidal Pulse Width Modulation)Control (V/f or sensorless vector control)
Frequency Setting Resolution
0.01Hz
Outing Frequency Resolution
0.01Hz
Torque Characteristics
Including the auto-torque/auto-slip compensation; starting torque can be 150% at 5.0Hz
Overload endurance
150% of rated current for 1 minute
Skip Frequency
Three zones, setting range 0~400Hz
Accel/Decel Time
0.1 to 600 seconds (2 Independent setting of Accel/Decel time)
Stall Prevention Level
Frequency Setting
20%-150%, Setting of Rated Current
DC injection Braking
Operation frequency 0~400Hz, output 0~30% rated current
Start time 0~60 seconds, stop time 0~60 seconds
Braking Torque
Approx, 20% (up to 125% possible with optional braking resistor or externally mounted brake unit
V/f Pattern
Adjustable V/f pattern
Operating Characteristics
Frequency Setting
Keypad
Setting by “UP” “Down”
External Signal
Potentiometer-5k ohm / 0.5W, 0 to +10VDC, 4 to 20mA, RS-485 interface; Multi-function Inputs 0 to 5(7 steps, Jog, up/down)
Operation Setting Signal
Keypad
Set by RUN and STOP
External Signal
2 wires/3 wires (RUN,STOP,FWD/ REV), JOG operation, RS-485 serial interface(MODBUS)
Multi-function Input signal
Multi-step selection 0 to 7, Jog, accel/decal inhibit, first to forth accel/decal switches, counter, PLC Operation external Base Block (NC,NO), axxiliary motor control is invalid, ACI/AVI/AUI selections, driver reset, UP/DOWN key setting, sink/source selection
Multi-function Output Indication
AC drive operating, frequency attained, non-zero frequency, Base Block, fault indication, local/remote, indication, auxiliary motor output, drive is ready, overheat alarm, emergency stop
Analog Output Signal
Analog frequency/current signal output
Alarm Output Contact
1 Form C contact or open collector output
Operation Functions
AVR, S-Curve, Over-Voltage, Over-Current Stall Prevention, Fault Records, Adjustable Carrier Frequency, DC Braking, Momentary Power Loss restart, Frequency Limits, Parameter Lock/Reset, Counter, PID Control, PLC, MODBUS Communication, Reverse Inhibition, Abnormal reset, abnormal re-start, digital frequency output, sleep/revival function,
Protection Functions
Self-testing, Over Voltage, Over Current, Under Voltage, Overload, Overheating, External Fault, Electronic thermal, Ground Fault
Display Keypad
6-key, 4-digit, 7-segment LED, 4 status LEDs, master frequency, output frequency, output current, custom units, parameter values for setup, review faults, RUN/STOP/RESET,FWD/REV
Built-in EMI Filter
VFD002S21E, VFD004S21E, VFD004S43E, VFD007S21E, VFD007S43E, VFD015S21E, VFD015S43E, VFD022S21E, VFD022S43E
Environmental
Conditions
Enclosure Rating
IP20
Pollution Degree
2
Installation Location
Altitude 1,000m or lower, keep from corrosive gasses, liquid and dust
Ambient Temperature
-100C to + 500C (400C for side-by-side mounting) Non-Condensing and not frozen
Storage/Transportation Temperature
-200C + 600C
Ambient Humidity
Below 90% RH (non-condensing)
Vibration
9.80665m/s2(1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz
Standard Specifications
115V series 1-phase
Model Number VFDXXXS
002
004
007
Max. Applicable Motor Output (kW)
0.2
0.4
0.75
Max. Applicable Motor Output(HP)
0.25
0.5
1.0
Output Rating
Rated Output Capacity(kVA)
0.6
1.0
1.6
Rated Output Current(A)
1.6
2.5
4.2
Maximum Output Voltage(V)
3-phase proportional to twice the input Voltage
Output Frequency (Hz)
0.1~400Hz
Carrier Frequency (kHz)
3-10
Input Rating
Rated Input Current(A)
Single Phase
6
9
16
Rated Voltage, Frequency
Single phase 100-120V, 50/60Hz
Voltage Tolerance
+-10%(90~132V)
Frequency Tolerance
+-5%(47~63Hz)
Cooling Method
Natural
Weight(kg)
1.3
1.5
2.0
230V Series 1-phase/3-phase
Model Number VFDxxxS21/23
002
004
007
015
022
Max. Applicable Motor Output (kW)
0.2
0.4
0.75
1.5
2.2
Max. Applicable Motor Output(HP)
0.25
0.5
1.0
2.0
3.0
Output Rating
Rated Output Capacity(kVA)
0.6
1.0
1.6
2.9
4.4/4
.2
Rated Output Current(A)
1.6
2.5
4.2
7.5
11.0
Maximum Output Current(V)
3-Phase Proportional to input voltage
Output Frequency (Hz)
0.1~400Hz
Carrier Frequency (kHz)
3-10
Input Rating
Rated Input Current(A)
Single/3-Phase
4.9/1.9
6.5/2.7
9.7/5.1
15.7/9.0
24/15
Single(3-phase Input Current)
1.6
3.0
5.1
8.4
--
Rated Voltage, Frequency
Single/3-phase 200-240V,50/60Hz
Voltage Tolerance
+-10%(180~264V)
Frequency Tolerance
+-5%(47~63V)
Cooling Method
Natural
Fan cooled
Weight(kg)
1.3
1.5
1.5
2.2
3.2
460V Series 3-phase
Model Number VFDXXXS
004
007
015
022
Max. Applicable Motor Output(kW)
0.4
0.75
1.5
2.2
Max. Applicable Motor Output(HP)
0.5
1.0
2.0
3.0
Output Rating
Rated Output Capacity(kVA)
1.2
2.0
3.3
4.4
Rated Output Current(A)
1.5
2.5
4.2
5.5
Maximum Output Voltage(V)
3-Phase Proportional to input voltage
Output Frequency(Hz)
0.1-400Hz
Carrier Frequency(kHz)
3-10
Input Rating
Rated Input Current(A)
3-phase
1.7
2.9
5.1
6.9
Rated Voltage, Frequency
3-phase 380~480V, 50/60Hz
Voltage Tolerance
+-10%(342~528V)
Frequency Tolerance
+-5%(47~63Hz)
Cooling Method
Natural
Fan Cooled
Weight(kg)
1.5
1.5
2.0
2.2
Dimensions
Standard wiring diagram