No comment |
>
Control System >
VFD >
Delta VFD >
Delta Inverter VFD drive VFD007CP43A-21 3Phase 380V 0.75KW 1HP 0~600Hz water pump &loomVFD007CP43A-21Features
Delta's Sensorless Vector Control Drive CP2000 Series has extended the idea of energy saving and uses this principal as the basis of its design. The CP2000 is specifically designed for applications such as air blowers, pumps and HVAC drives with its intelligent PID control providing the greatest efficiency. The Sensorless Vector Control (SVC) offers timely response to load torque increase/decrease which satisfies customer requirements for load changes while enhancing motor performance. A 3-step V/F curve response is used in the variable torque environment to adequately adjust the input voltage and attain the greatest overall performance; this function is especially helpful in pumps and fans applications. It also includes additional functions for operation and protection in variable load environments, such as flying starts, auto-acceleration/deceleration, momentary power loss restarts, auto-tuning, and more. The CP2000 series provides you with the ultimate energy-saving solution for your applications.
Specifications
?With a built-in 10K steps Delta PLC allows user to execute distributional control and independent control when connecting to a network system. Delta CP2000 series drives provide you the intelligent control possibility beyond your imagination.
?The calendar function allows user to program the PLC procedure, the ON/OFF in chronological order, the daylight saving time and etc.
?A wide range of models (0.75~400KW) to fulfill the demands of different industries.
?The modularized design eases the maintenance and expansion.
?High speed communication interfaces with MODBUS protocol and BACnet protocol built in. Diverse communication methods to satisfy clients needs on multi-controls. So the following options are available for you: the ProfiBUS-DP, the DeviceNet, the MODBUS TCP, the Ethernet-IP and the CANopen Cards.
?Long-life design and self diagnosis for key components.
?Special PCB coating design (Printed Circuit Board) for enhancing environmental tolerance.
?Complied with global safety standards: CE, UL and cUL
?Standard LCD model (IP20/NEMA1) with built-in PLC to support up to 10K steps
?Excellent heat-sink design. Able to operate at 50°C ambient temperature and to adjust automatically rated output value to make the AC drive to work continuously.
?Run fire mode while emergency to have uninterrupted smoke releasing and pressure adding
?Multi pumps control at fixed amount, fixed time circulating control. Able to control 8 pumps at the same time. (Such as Image01 and Image02, optional multi-control relay card is required.)
Product Specifications
230V Series
Frame Size
A
B
C
D
E
Model: VFD-xxxCP23_-_
007
015
022
037
055
075
110
150
185
220
300
370
450
550
750
900
Output Rating
Light Duty
Rated Output Capacity(kVA)
2.0
3.0
4.0
6.0
8.4
12
18
24
30
36
42
58
72
86
110
128
Rated Output Current(A)
5
7.5
10
15
21
31
46
61
75
90
105
146
180
215
276
322
Applicable Motor Output(kW)
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
90
Applicable Motor Output(HP)
1
2
3
5
7.5
10
15
20
25
30
40
50
60
75
100
125
Overload Tolerance
120% of rated current for 1 minute
Normal Duty
Rated Output Capacity(kVA)
1.2
2.0
3.2
4.4
6.8
10
13
20
26
30
36
48
58
72
86
102
Rated Output Current(A)
3
5
8
11
17
25
33
49
65
75
90
120
146
180
215
255
Applicable Motor Output(kW)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
18.5
22
30
37
45
55
75
Applicable Motor Output(HP)
0.5
1
2
3
5
7.5
10
15
20
25
30
40
50
60
75
100
Overload Tolerance
120% of rated current for 1 minute; 160% of rated current for 3 seconds
Max. Output Frequency(Hz)
600.00Hz
400.00Hz
Carrier Frequency(kHz)
2~15kHz(8KHz)
2~10kHz(6KHz)
2~9kHz(4KHz)
Input Rating
Input Current(A)Light Duty
6.4
9.6
15
22
25
35
50
65
83
100
116
146
180
215
276
322
Input Current(A)Normal Duty
3.9
6.4
12
16
20
28
36
52
72
83
99
124
143
171
206
245
Rated Voltage/Frequency
3-Phase AC 200V-240V(-15%~+10%), 50/60Hz
Operating Voltage Range
17~265Vac
Frequency Tolerance
47~63Hz
Cooling Method
Natural Coolong
Fan Cooling
Braking Chopper
Frame A, B, C built in
Frame D and above: optional
DC Choke
Frame A, B, C optional
Frame D and above: 3% built in
EMI Filter
Optional
460V Series
Frame
A
B
C
Models: VFD-xxxCP43_-_
VFD-xxxCP4E_-_
007
015
022
037
040
055
075
110
150
185
220
300
370
Output Rating
Light Duty
Rated Output Capacity(kVA)
2.4
3.3
4.4
6.8
8.4
10.4
14.3
19
25
30
36
48
58
Rated Output Current(A)
3
4.2
5.5
8.5
10
.5
13
18
24
32
38
45
60
73
Applicable Motor Output (kW)
0.75
1.5
2.2
3.7
4.0
5.5
7.5
11
15
18.5
22
30
37
Applicable Motor Output (HP)
1
2
3
5
5
7.5
10
15
20
25
30
40
50
Overload Tolerance
120% of rated current for 1 minute
Normal Duty
Rated Output Capacity(kVA)
2.2
2.4
3.2
4.8
7.2
8.4
10
14
19
25
30
36
48
Rated Output Current(A)
1.7
3.0
4.0
6.0
9.0
10.5
12
18
24
32
38
45
60
Applicable Motor output (kW)
0.4
0.75
1.5
2.2
3.7
4.0
5.5
7.5
11
15
18.5
22
30
Applicable Motor Output(HP)
0.5
1
2
3
5
5
7.5
10
15
20
25
30
40
Overload Tolerance
120% of rated current for 1 minute; 160% of rated current for 3 seconds
Max. output Frequency(Hz)
600.00Hz
Carrier Frequency(kHz)
2~15kHz(8kHz)
2~10kHz(6kHz)
Input Rating
Input Current(A) Light Duty
4.3
6.0
8.1
12.4
16
20
22
26
35
42
50
66
80
Input Current(A) Normal Duty
3.5
4.3
5.9
8.7
14
15.5
17
20
26
35
40
47
63
Rated Voltage/ Frequency
3-Phase AC 380V~480V(-15%~+10%), 50/60Hz
Operating Voltage Range
323~528Vac
Frequency Tolerance
47~63Hz
Cooling Method
Natural Cooling
Fan Cooling
Braking Chopper
Frame A, B, C Built-in
DC Choke
Frame A, B, C Optional
EMI Filter
Frame A, B, C of VFDxxxCP4E_-__, EMI filter Built-in
Frame A, B, C of VFDxxxCP43E_-__, EMI filter not Built-in
Frame
D
E
F
G
H
Models: VFD-xxxCP43_-_
450
550
750
900
1100
1320
1600
1850
2200
2800
3150
3550
4000
Output Rating
Light Duty
Rated Output Capacity(kVA)
73
88
120
143
175
207
247
295
367
422
491
544
613
Rated Output Current(A)
91
110
150
180
220
260
310
370
460
530
616
683
770
Applicable Motor Output (kW)
45
55
75
90
110
132
160
185
220
280
315
355
400
Applicable Motor Output (HP)
60
75
100
125
150
175
215
250
300
375
425
475
536
Overload Tolerance
120% of rated current for 1 minute
Normal Duty
Rated Output Capacity(kVA)
58
73
88
120
143
175
207
247
295
367
438
491
544
Rated Output Current(A)
73
91
110
150
180
220
260
310
370
460
550
616
683
Applicable Motor output (kW)
37
45
55
75
90
110
132
160
185
220
280
315
355
Applicable Motor Output(HP)
50
60
75
100
125
150
175
215
250
300
375
425
475
Overload Tolerance
120% of rated current for 1 minute; 160% of rated current for 3 seconds
Max. output Frequency(Hz)
600.00Hz
400.00Hz
Carrier Frequency(kHz)
2~10kHz(6kHz)
2~9kHz(4kHz)
Input Rating
Input Current(A) Light Duty
91
110
150
180
220
260
310
370
460
530
616
683
770
Input Current(A) Normal Duty
74
101
114
157
167
207
240
300
380
400
494
555
625
Rated Voltage/ Frequency
3-Phase AC 380V~480V(-15%~+10%), 50/60Hz
Operating Voltage Range
323~528Vac
Frequency Tolerance
47~63Hz
Cooling Method
Fan Cooling
Braking Chopper
Frame D and above: Optional
DC Choke
Frame D and above: 3% Built-in
EMI Filter
Frame D and above: Optional
Applications
Fixed-displacement pumps (fix flow and fix time), building automation, factory automation, HVAC drives, cooling pumps, cooling towers and general motor applications.
Wiring Diagram
No comment |