The Delta VFD-E AC Drive is a Sensorless Vector frequency inverter. The VFD-E series represent Delta Electronics low power, constant torque, IP20 rated AC Drive. Modular in design with flexible extension cards and a built-in PLC function, the Delta VFD-E AC Drive offers the ability to write and to execute simple Ladder Logic programs. This state-of-the-art series meets a full range of application requirements.
Power: 1.5kW Amps: 7.5Supply: Single Phase 200/240vModel: Delta VFD015E21AFilter: Built-InPerformance: Mid RangeDimensions: 72 x 142 x 152Weight: 1.9kgTorque: Constant Torque General Purpose
Features of the Delta VFD-E AC Drive frequency inverter:
PLC function - Built-in PLC function, the Delta VFD-E AC Drive offers the ability to write and to execute simple Ladder Logic programs.Modular Design - Modular structure and extension with Optional cardsStandard MODBUS Protocol - Standard MODBUS protocol via RS-485Built-in EMI Filter (230V 1-phase and 460V 3-phase) - To reduce electromagnetic interference EfficientlyCompact Design - Space saving and easy DIN rail mounting with optional DIN rail adapterOptional Fieldbus Modules - Provide connection to a variety of networks, including Profibus, DeviceNet, Low Works and CANopenFlexible Extension - Via optional cards, such as I/O card, Relay card, PG (Encoder) card and USB Card, to meet your application requirements.RFI-Switch for IT Mains - Removable “Y” capacitor to use with IT mains supplies.
Applications:
Smaller cranes; washing machines; treadmilsl; robot arm of injection machine (clamp); elevator; grinding machine; drilling machine; wood machine; webbing loom; air conditioner for large buildings; water supply system for large buildings, etc.
General Specifications
Control Characteristics
Control System
SPWM (Sinusoidal Pulse Width Modulation)Control (V/f or sensorless vector control)
Frequency Setting Resolution
0.01Hz
Outing Frequency Resolution
0.01Hz
Torque Characteristics
Including the auto-torque/auto-slip compensation; starting torque can be 150% at 3.0Hz
Overload endurance
150% of rated current for 1 minute
Skip Frequency
Three zones, setting range 0.1~600Hz
Accel/Decel Time
0.1 to 600 seconds (2 Independent setting of Accel/Decel time)
Stall Prevention Level
Setting 20 to 250% of rated current
DC Braking
Operation frequency 0.1~600.0Hz, output 0~100% rated current
Start time 0~60 seconds, stop time 0~60 seconds
Regenerated Braking Torque
Approx, 20% (up to 125% possible with optional brake resistor or externally mounted brake unit, 1-15hp models(built-in brake chopper)
V/f Pattern
Adjustable V/f pattern
Operating Characteristics
Frequency Setting
Keypad
Setting by “UP” “Down”
External Signal
Potentiometer-5k ohm / 0.5W, 0 to +10VDC, 4 to 20mA, RS-485 interface; Multi-function Inputs 3 to 9(15 steps, Jog, up/down)
Operation Setting Signal
Keypad
Set by RUN and STOP
External Signal
2 wires/3 wires (FWD, REV, EF), JOG operation, RS-485 serial interface(MODBUS), programmable logic controller
Multi-function Input signal
Multi-step selection 0 to 15, Jog, accel/decal inhibit, 2 accel/decal switches, counter, external Base Block (NC,NO), axxiliary motor control is invalid, ACI/AVI/AUI selections, driver reset, UP/DOWN key setting, sink/source(-NPN/PNP) selection
Multi-function Output Indication
AC drive operating, frequency attained, non-zero frequency, Base Block, fault indication, local/remote, indication, auxiliary motor output, drive is ready, overheat alarm, emergency stop and status selections of input terminals(NC/NO)
Analog Output Signal
Output frequency/current
Alarm Output Contact
Contact will be On when drive malfunctions (1 Form C/Change-over contact or 1 open collector output)
Operation Functions
Built-in PLC, AVR, accel/decal S-Curve, over-voltage/over-current stall prevention, 5 fault records, reverse inhibition, momentary power loss restart, DC braking , auto torque/slip compensation, auto tuning, adjustable carrier frequency, output frequency limits, parameter lock/reset, vector control, PID control, external counter, MODBUS communication, abnormal reset, abnormal re-start, power-saving, sleep/wake function, fan control 1st/snd frequency source selections, 1st/2nd frequency source combination.
Protection Functions
Over voltage, over current, under voltage, under current, external fault, overload, ground fault over heating, electronic thermal, IGBT short circuit, PTC
Display Keypad
6-key, 7-segment LED with 4-digit, 5 status LED, master frequency, output frequency, output current, custom units, parameter values for setup and lock, faults, RUN/STOP/RESET,FWD/REV
Built-in EMI Filter
For 230V 1-phase and 460V 3-phase models
Environmental
Conditions
Enclosure Rating
IP20
Pollution Degree
2
Installation Location
Altitude 1,000m or lower, keep from corrosive gasses, liquid and dust
Ambient Temperature
-100C to + 500C (400C for side-by-side mounting) Non-Condensing and not frozen
Storage/Transportation Temperature
-200C + 600C
Ambient Humidity
Below 90% RH (non-condensing)
Vibration
9.80665m/s2(1G) less than 20Hz, 5.88m/s2 (0.6G) at 20 to 50Hz
Detailed Specifications
Diagram 1
Voltage Class
115V
Model Number VFDXXXE
002
004
007
Max. Applicable Motor Output (kW)
0.2
0.4
0.75
Max. Applicable Motor Output (hp)
0.25
0.5
1.0
Output Rating
Rated Output Capacity (kVA)
0.6
1.0
1.6
Rated Output Current (A)
1.6
2.5
4.2
Maximum Output Voltage(V)
3-phase proportional to twice the input voltage
Output Frequency(Hz)
0.1~600Hz
Carrier Frequency(kHz)
1-15
Input Rating
Rated Input Current(A)
Single-phase
6
9
18
Rated Voltage/Frequency
Single phase 100-120V, 50/60Hz
Voltage Tolerance
+-10%(90-132V)
Frequency Tolerance
+-5%(47-63Hz)
Cooling Method
Natural Cooling
Fan Cooling
Weight(kg)
1.2
1.2
1.2
Diagram 2
Voltage Class
230V
Model Number VFDXXXE
002
004
007
015
022
037
055
075
110
150
Max. Applicable Motor Output (kW)
0.2
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11
15
Max. Applicable Motor Output(hp)
0.25
0.5
1.0
2.0
3.0
5.0
7.5
10.0
15
20
Output Rating
Rated Output Capacity(kVA)
0.6
1.0
1.6
2.9
4.2
6.5
9.5
12.5
17.1
25
Rated Output Current(A)
1.6
2.5
4.2
7.5
11.0
17
25
33
45
65
Maximum Output Voltage(V)
3-phase proportional to input voltage
Output Frequency(Hz)
0.1~600Hz
Carrier Frequency(kHz)
1-15
Input Rating
Rated Input Current(A)
Single/3-phase
3-phase
4.9/1.9
6.5/2.7
9.7/5.1
15.7/9
24/15
20.6
26
34
48
70
Rated Voltage/Frequency
Single/3-phase, 200-240V, 50/60Hz
3-phase, 200-240V, 50/60Hz
Voltage Tolerance
+-10% (180-264V)
Frequency Tolerance
+-5%(47-63Hz)
Cooling Method
Natural Cooling
Fan Cooling
Weight(kg)
1.1
1.1
1.1
1.9
1.9
1.9
3.5
3.5
3.57
6.6
Diagram 3
Voltage Class
460V
Model Number VFDXXXE
004
007
015
022
037
055
075
110
150
185
220
Max. Applicable Motor Output (kW)
0.4
0.75
1.5
2.2
3.7
5.5
7.5
11.0
15
18.5
22
Max. Applicable Motor Output(hp)
0. 5
1.0
2.0
3.0
5.0
7.5
10.0
15.0
20
25
30
Output Rating
Rated Output Capacity(kVA)
1.2
2.0
3.3
4.4
6.8
9.9
13.7
18.3
24
29
34
Rated Output Current(A)
1.5
2.5
4.2
5.5
8.5
13.0
18.0
24.0
32
38
45
Maximum Output Voltage(V)
3-phase proportional to input voltage
Output Frequency(Hz)
0.1~600Hz
Carrier Frequency(kHz)
1-15
Input Rating
Rated Input Current(A)
3-phase
1.9
3.2
4.3
7.1
11.2
14
19
26
35
41
49
Rated Voltage/Frequency
3-phase, 380-480V, 50/60Hz
Voltage Tolerance
+-10% (342-528V)
Frequency Tolerance
+-5%(47-63Hz)
Cooling Method
Natural Cooling
Fan Cooling
Weight(kg)
1.2
1.2
1.2
1.9
1.9
4.2
4.2
4.2
7.47
7.47
7.47
Dimensions