No comment |
>
Control System >
VFD >
Delta VFD >
Delta Inverter VFD Drive VFD007EL21A 1Phase 220V 0.75kW 1HP 0.1~600Hz Water pump &Packaging machine1 Phase 220V 0.75kW 1 HP Delta VFD Drive VFD007EL21A Inverter
Features:
The VFD-EL series is multiple functions new generation micro type AC drives. It has built in EMI filter, RFI switch, easy DC bus sharing for side-by-side installation, high precision current detection, overload protection, and a built in keypad.
Specifications
?Output frequency: 0.1 ~ 600Hz
?3 points adjustable V/f curve
?Built-in PID feedback control
?RFI-switch for IT mains
?Built-in EMI filter (for models 230V 1-phase and 460V 3-phase)
?Use RS-485 communication interface (RJ-45) with Modbus protocol
?Optional communication modules for multiple communication protocols, such as Profibus, DeviceNet, LonWorks and CANopen
?Complete protection function
Applications
Small size pump & fan, blowing machine, conveyer belt, simple DIY processing equipment.
General Specifications
Control characteristics
Control System
SPWM(Sinusoidal Pulse Width Modulation) control (V/F control)
Frequency Setting Resolution
0.01Hz
Output Frequency Resolution
0.01Hz
Torque Characteristic
Including the auto-torque/auto/slip compensation: starting torque can be 150% at 5.0Hz
Overload Endurance
150% of rated current for 1 minute
Skip Frequency
Three zones, setting range 0.1-600Hz
Accel/Decel Time
0.1 to 600 seconds(2 Independent settings for Accel/Decel time)
Stall Prevention Level
Setting 20 to 250% of rated current
DC Braking
Operation frequency 0.1-600.0Hz, output 0-100% rated current
Starting time 0-60 seconds, stop time 0-60 seconds, stop time 0-60 seconds
Regenerated Braking Torque
Approx. 20% (up to 125% possible with optional brake resistor or externally mounted brake unit,
1-15hp(0.75-11kw)models have brake chopper built-in)
V/F Pattern
Adjustable V/f pattern
Operating Characteristics
Frequency Setting
Keypad
Setting by up and down
External Signal
Potentiometer-5K/0.5W, 0 to + 10VDC, 4 to 20mA, RS-485 interface;
Multi-function Inputs 3 to 6(15 steps, Jog, up/down)
Operation Setting Signal
Keypad
Set by RUN and STOP
External Signal
2 wires/3 wires(MI1, MI2,MI3), JOG operation, RS-485 serial interface(MODBUS), programmable logic controller
Multi-function Input signal
Multi-step selection 0 to 15, Jog, accel/decel inhibit, 2 accel/decel switches, counter, external Base Block, ACI/AVI selections, driver reset, Up/DOWN key setting, NPN/PNP input selection
Multi-function Output Indication
AC drive operation, frequency attained, counter attained, zero speed, Base Block, fault indication, overheat alarm, emergency stop and statues selections of input terminals
Analog Output signal
Output frequency/current
Alarm Output Contact
Contact will be ON when drive malfunctions (1 Form C/change-over contact or 1 open collector output)
Operation Functions
AVR, accel/decel S-Curve, over-voltage/over-current stall prevention, 5 fault records, reverse inhibition, momentary power loss restart, DC braking, auto torque/slip compensation, adjustable carrier frequency, output frequency limits, parameter lock/reset, PID control, external counter, MODBUS communication, abnormal reset, abnormal re-start, power-saving, fan control, sleep/wake frequency, 1st/2ne frequency source selections, 1st/2nd frequency source combination, NPN/PNP selection, constant pressure function
Protection Functions
Over voltage, over current, under voltage, external fault, overload, ground fault, overheating ,electronic thermal, IGBT short circuit, PTC
Display Keypad
6-key, 7-segment LED with 4-digit, 4 status LEDs, master frequency, output frequency, output current, custom units, parameter values for setup and lock, faults, RUN, STOP, RESET, FWD/REV
Built-in EMI Filter
For 230V 1-phase and 460V 3-phase models.
Environmental Conditions
Enclosure Rating
IP20
Pollution Degree
2
Installation Location
Altitude 1000m or lower, keep from corrosive gasses, liquid and dust
Ambient Temperature
-100C to 500C(400C for side-by-side mounting) Non-condensing and not frozen
Storage/Transportation Temperature
-200C to 600C
Ambient Temperature
Below 90% RH(non-condensing)
Vibration
9.80665m/s2(1G) less than 20Hz, 5.88m/s2(0.6G) at 20 to 50Hz
Precise Specifications
Diagram 1
Voltage Class
115V
Model Number VFDxxxEL
002
004
007
Max. Applicable Motor Output(kW)
0.2
0.4
0.75
Max. Applicable Motor Output (HP)
0.25
0.5
1.0
Output Rating
Rated Output Capacity(kVA)
0.6
1.0
1.6
Rated Output Current(A)
1.6
2.5
4.2
Maximum Output Voltage(V)
3-phase Proportional to Twice the Input Voltage
Output Frequency(Hz)
0.1~600Hz
Carrier Frequency(kHz)
2-12
Input Rating
Rated Input Current(A)
Single-phase
6.4
9
18
Rated Voltage/Frequency
Single phase, 100-120V, 50/60Hz
Voltage Tolerance
+-20%(90~132V)
Frequency Tolerance
+-5%(47~63Hz)
Cooling Method
Natural Cooling
Weight(kg)
1.1
1.1
1.4
Diagram2
Voltage Class
230V
Model Number VFDxxxEL
002
004
007
015
022
037
Max. Applicable Motor Output(kW)
0.2
0.4
0.7
1.5
2.2
3.7
Max. Applicable Motor Output (HP)
0.25
0.5
1.0
2.0
3.0
5.0
Output Rating
Rated Output Capacity(kVA)
0.6
1.0
1.6
2.9
4.2
6.5
Rated Output Current(A)
1.6
2.5
4.2
7.5
11.0
17.0
Maximum Output Voltage(V)
3-phase Proportional to Input Voltage
Output Frequency(Hz)
0.1~600Hz
Carrier Frequency(kHz)
2-12
XXXEL21A
Rated Input Current(A)
4.9
6.5
9.5
15.7
24
--
Rated Voltage/Frequency
1-phase, 200-240V, 50/60Hz
XXXEL23A
Rated Input Current(A)
1.9
2.7
4.9
9
14
20.6
Rated Voltage/Frequency
3-phase, 200-240V, 50/60Hz
Voltage Tolerance
+-10%(180-264V)
Frequency Tolerance
+-5%(47-63Hz)
Cooling Method
Natural Cooling
Fan cooling
Weight(kg)
1.2
1.2
1.2
1.7
1.7
1.7
Diagram3
Voltage Class
460V
Model Number VFDxxxEL
004
007
015
022
037
Max. Applicable Motor Output(kW)
0.4
0.75
1.5
2.2
3.7
Max. Applicable Motor Output (HP)
0.5
1.0
2.0
3.0
5.0
Output Rating
Rated Output Capacity(kVA)
1.2
2.0
3.3
4.4
6.8
Rated Output Current(A)
1.5
2.5
4.2
5.5
8.2
Maximum Output Voltage(V)
3-phase Proportional to Input Voltage
Output Frequency(Hz)
0.1~600Hz
Carrier Frequency(kHz)
2-12
Input Rating
Rated Input Current(A)
3-phase
1.8
3.2
4.3
7.1
9.0
Rated Voltage/Frequency
3-phase, 380-480V, 50/60Hz
Voltage Tolerance
+-10%(180-264V)
Frequency Tolerance
+-5%(47-63Hz)
Cooling Method
Natural Cooling
Fan cooling
Weight(kg)
1.2
1.2
.1.2
1.7
1.7
1.7
Dimensions
Standard wiring diagram