Features:
Sub-fractional low cost AC Drive. Specifically designed for low horsepower applications with built-in EMI filter to efficiently reduce electromagnetic interference and to conform to the CE EMI directive.
Specifications
Output frequency 1.0 ~ 400HzAdjustable V/f curve?Carrier frequency up to 10 kHzAuto torque boost and slip compensationBuild-in MODBUS communication, baud rate up to 9600 bpsBuilt-in EMI filterMounting: PanelHeight: 5.2 InchesWidth: 2.68 InchesDepth: 5.04 InchesH x W x D (in.): 5.2 x 2.68 x 5.04
Applications
Simple wood cutting, conveyer belt, wire drawing machine, etc.
Standard Specifications
Voltage Class
115V
230V
Model Name VFD-XXXLXXA/B
002
004
002
004
007
015
Applicable Motor Output(kW)
0.2
0.4
0.2
0.4
0.7
1.5
Output Rating
Rated Output Capacity(KVA)
0.6
1.0
0.6
1.0
1.6
2.7
Rated Output Current(A)
1.6
2.5
1.6
2.5
4.2
7.0
Max.Output Voltage(V)
3 Phase double the input
Proportional to input voltage
Rated Frequency(Hz)
1.0~400Hz
Power
Rated Input Current(A)
6
9
4.9/1.9
6.5/2.7
9.7/5.1
*/9
Input Voltage Tolerance
Single phase
100~120V 50/60Hz
Single/3-phase 200~240V 50/60Hz
3-phase
200~240V
50/60Hz
Frequency Tolerance
+-5%
Control characteristics
Control system
SVPWM(Space Vector Pulse Width Modulation, carrier frequency 3kHz~10kHz)
Output Frequency Resolution
0.1Hz
Torque Characteristics
Including auto-torque and auto-slip compensation, the starting torque is 150% at 5Hz
Overload Endurance
150% of rated current for 1 minute
Accel/Decel Time
0.1~600Sec. (can be set indiviadually)
V/F Pattern
Adjustable V/F curve
Stall Prevention Level
20~200% of rated output current
Operating Characteristics
Frequency
Setting
Keypad
Potentiometer-5K/0.5W, DC 0~+10V(input impedance 100K), 4~20mA(output Impedance 250 ohm), 3 multi-function inputs(3 preset speeds, JOG, UP/DOWN command), communication setting
External Signal
Operation Setting
Keypad
RUN/STOP keys
Signal
External Signal
M0, M1,M2,M3 can be combined to offer varlous modes of operation, RS-485 communication port
Multi-function Input Signal
Multi-step speed selection 0~3, Jog, accel/decal inhibit, first/second accel/decal selector, counter, PLC operation, external base block(NC, NO) selection
Multi-function Output Signal
Ac Drive Operating, Frequency Attained, Non-zero speed, Base Block, Fault Indication, Local/Remote control indication, PLC Operation indication.
Other Function
AVR, S-curve, Over-Voltage Stall Prevention, DC Braking, Fault Records, Adjustable Carrier-Frequency, Over-Current Stall Prevention, Momentary Power Loss restart, Reverse inhibit, Frequency Limits, Patameter Lock/Reset.
Protection
Over Voltage, Over Current, Under Voltage, Overload, Overheating, Self-testing, Ground fault
Other
Built-in EMI Filter for Frame B(single phase)
cooling
Forced air-cooling
Environment
Installation Location
Altitude 1000 m or below, keep from corrosive gasses, liquid and dust
Ambient Temperature
-100C to + 400C(Non-Condensing and not frozen)
Storage Temperature
-200C to + 600C
Ambient Humidity
Below 90% RH(non-condensing)
Vibration
9.80665m/s2(1G) less than 20Hz,5.88m/s2(0.6Gat) 20 to 50Hz
Wiring