No comment |
>
Control System >
VFD >
ABB VFD Drive >
ACS550-01-059A-4 ABB Inverter New in boxACS550-01-059A-4 ABB Inverter New in boxProduct Description:
The ABB ACS550 AC drive combines a sophisticated microprocessor with an advanced IGBT power switching technology to deliver V/Hz, Closed Loop Flux Vector and Sensor less Vector control of AC motors. Its intuitive control panel offers numerous benefits making it the most user friendly panel in the drives industry. The extensive library of pre-programmed application macros maximizes convenience and minimizes start-up time. This drive can handle the most demanding industrial applications in an efficient, dependable and economic manner.
Features:
System Voltage
Base Drive Type Code
Frame Size
NominNormal Duty
al Ratings Heavy Duty
Base Drive NEMA 1 Dim Ref UX1
Base Drive NEMA 12 Dim Ref UX12
Bypass NEMA 1 Dim Ref CX1
Bypass NEMA 12 Dim Ref CX12
Bypass NEMA 3R Dim Ref CX3R
Input Disconnect NEMA 1 Dim Ref PX1
Input Disconnect NEMA 12 Dim Ref PX12
Input Disconnect NEMA 3R Dim Ref PX3R
I2N A
PN HP
I2hd A
Phd HP
480V
ACS550-XX-03A3-4
R1
3.3
1.5
2.4
1
1
1
1
1
1
1
1
1
ACS550-XX-04A1-4
R1
4.1
2
3.3
1.5
1
1
1
1
1
1
1
1
ACS550-XX-06A9-4
R1
6.9
3
5.4
2
1
1
1
1
1
1
1
1
ACS550-XX-08A8-4
R1
8.8
5
6.9
3
1
1
1
1
1
1
1
1
ACS550-XX-012A-4
R1
11.9
7.5
8.8
5
1
1
1
1
1
1
1
1
ACS550-XX-015A-4
R2
15.4
10
11.9
7.5
2
2
2
2
2
2
2
2
ACS550-XX-023A-4
R2
23
15
15.4
10
2
2
2
2
2
2
2
2
ACS550-XX-031A-4
R3
31
20
23
15
3
3
4
4
3
3
3
3
ACS550-XX-038A-4
R3
38
25
31
20
3
3
4
4
3
3
3
3
ACS550-XX-045A-4
R3
44
30
38
25
3
3
4
5
3
3
3
3
ACS550-XX-059A-4
R4
59
40
44
30
4
4
5
6
4
4
4
4
ACS550-XX-072A-4
R4
72
50
59
40
4
4
5
6
4
4
4
4
ACS550-XX-078A-4
R4
77
60
65
50
4
4
5
6
4
4
4
4
ACS550-XX-097A-4
R4
96
75
77
60
4
4
6
7
5
5
5
5
ACS550-XX-125A-4
R5
124
100
96
75
5
5
7
8
6
5
5
6
ACS550-XX-157A-4
R6
157
125
124
100
6
6
10
9
7
6
6
6
ACS550-XX-180A-4
R6
180
150
156
125
6
6
10
9
7
6
6
6
ACS550-XX-246A-4
R6
245
200
192
150
6
6
11
10
8
6
6
6
ACS550-XX-316A-4
R8
316
250
240
200
8
12
11
8
8
ACS550-XX-368A-4
R8
368
300
302
250
8
13
12
8
8
ACS550-XX-414A-4
R8
414
350
368
300
8
13
12
8
8
ACS550-XX-486A-4
R8
486
400
414
350
8
13
12
8
8
ACS550-XX-526A-4
R8
526
450
477
400
8
8
ACS550-XX-602A-4
R8
602
500
515
450
8
8
ACS550-XX-645A-4
R8
645
550
590
500
8
8
Notes:
1 I2N: continuous base current with 110% overload for 1 minute / 10 minutes.
2 I2hd : continuous base current with 150% overload for 1 minute / 10 minutes.
3 180% Ihd continus base current available for 2 s /1 minute.
4 The rated current of the ACS550 must be greater than or equal to the rated motor current to achieve the rated motor power given in the table.
5 All -U1 models come with a conduit box and advanced control panel as standard.
6 Horsepower is based on NEMA motor ratings for most
4-pole motors (1800 rpm). Check motor nameplate current for compatibility.
7 All 230V Product can be operated on 230V single-phase power, using a rate of the output current of 50%.
8 All -U2 models come standard with US conduit openings, top entry / top exit, common mode flter for drives larger than 200 HP, fused disconnect and extended enclosure with advanced control panel.
Dim
Frame
Mounting Dimensions
Shipping Dimensions
Dimension Drawing
H1
W1
Mounting Hardware
H
W
D
Weight
UX1-1
R1
12.5
3.9
#10
14.5
4.9
8.3
14.3
3AUA0000001559 -sheet 1
UX1-2
R2
16.4
3.9
#10
18.5
4.9
8.7
19.5
3AUA0000001560 -sheet 1
UX1-3
R3
18.6
6.3
#10
23
8
9.1
35
3AUA0000001571 -sheet 1
UX1-4
R4
22.8
6.3
#10
27.1
8
10.3
53
3AUA0000001572 -sheet 1
UX1-5
R5
23.2
9.4
0.25
29
10.5
11.3
75
3AUA0000004629 -sheet 1
UX1-6
R6
26.6
10.4
0.25
35
11.9
15.8
152
3AUA0000004633 -sheet 1
UX1-7
R7
Free Standing
NA
59.2
24
19.5
430
Consult Factory
UX1-8
R8
Free Standing
NA
83.9
31.5
23
827
Consult Factory
Technical Specification:
Input power connection
Programmable control connections
Voltage and power range
3-phase, 208 to 240 V, +10/-15%, 0.75 - 100Hp
3-phase, 380 to 480 V, +10/-15%, 1 - 550Hp
3-phase, 500 to 600V, +10/-15%, 1.5 - 150HpTwo analog inputs
Frequency
48 to 63 Hz
Voltage signal
0 (2) to 10 V, Rin > 312 kΩsingle-ended
Power factor
0.98
Current signal
0 (4) to 20 mA, Rin = 100 Ωsingle-ended
Motor connection
Potentiometer reference value
10 V ±2% max. 10 mA, R < 10 kΩ
Voltage
3-phase, from 0 to USUPPLY
Environmental limits
Frequency
0 to 500 Hz
Ambient temperature
-15 to 40? D840 to 50?
Continuous loading capability
Rated output current I2N
No frost allowed
Overload capacity (at a max. ambient tempera-ture of 400c)
At normal use 1.1 x I2N for 1 minute every 10 minutes
Altitude
At heavy-duty use 1.5 x I2hd for 1 minute every 10 minutes
Output current
Rated current available at 0 to 1000 m (3300 ft)
reduced by 1% per 100 m over 1000 m (3300 ft)
to 2000 m (6600 ft)Always 1.8 x I2hd for 2 seconds every 60 seconds
Relative humidity
lower than 95% (without condensation)
Switching frequency
Protection class
UL Type 1 or 12 (NEMA 1 or NEMA 12)
Standard
Default 4 kHz
Enclosure colour
NCS 1502-Y, RAL 9002, PMS 420 C
Selectable
0.75 - 150Hp 1 kHz, 4 kHz, 8 kHz, 12 kHz
Contamination levels
IEC 721-3-3
up to 550Hp 1 kHz, 4 kHz
Transportation
Class 1C2 (chemical gases), Class 1S2 (solid particles)
Acceleration time
0.1 to 1800 s
Storage
Class 2C2 (chemical gases), Class 2S2 (solid particles)
Deceleration time
0.1 to 1800 s
Operation
Class 3C2 (chemical gases), Class 3S2 (solid particles)
No comment |