Your Position: Home > Control System > PLC > Other PLC > K7M-DT30U LS PLC New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

K7M-DT30U LS PLC New

prevnext

K7M-DT30U LS PLC New
  • Market price: $ 732.6
  • Shop price: $ 222.0
  • Goods click count: 632
  • Total:
  • Quantity:
Add to cart collect
  

Description

LS (LG) PLC K7M-DT30U

Product Description:

Digital input that offers to MASTER-K120S series are made to use both of electric current sink and electric current source. To keep use coil load as an output module, maximum opening and shutting frequency is 1 second on and 1 second off.

Features:

Model
Specification(Input)

 Main unit

K7M-DR10UE

K7M-DR14UE

K7M-DR/DRT/DT20U K7M-DR20UE

K7M-DR/DRT/DT30U K7M-DR30UE

K7M-DR/DRT/DT40U K7M-DRT40U

K7M-DR/DRT/DT60U K7M-DRT60U

 Number of input points

 6 points  

 8 points  

 12 points

 18 points

 24 points

 36 points  

 Insulation method

 Photo coupler  

 Rated input voltage

 DC 24V  

 Rated input current

 7mA (Standard Type P0~P3:9mA, Economic Type P0,P1:9mA)  

 Operating voltage range  

 DC20.4 ~ 28.8V (ripple: less than 5%)  

 Max. simultaneous input points

 100% simultaneously On  

 On voltage / On current

 DC19V or higher / 5.7mA or higher  

 Off voltage / Off current

 DC6V or lower / 1.8mA or lower  

 Input impedance

 Approx.3.3kΩ (Standard Type P0~P3:2.7kΩ, Economic Type P0,P1:2.7kΩ)  

 Response time  

Off → On

 0,1,2,5,10,20,50,100,200,500,1000ms (Default : 10ms)  

On → Off

 0,1,2,5,10,20,50,100,200,500,1000ms (Default : 10ms)  

 Common terminal

6 points / COM

 8 points/COM

 12 points/COM

 18 points/ COM

 12points/COM

 18points/COM

 Operating indicator

 LED turns on at ON state of input  

Relay Output:

Model
Specifications

 Main Unit  

 K7M-DR20U (K7M-DRT20U)  

 K7M-DR30U (K7M-DRT30U)  

 K7M-DR40U (K7M-DRT40U)  

 K7M-DR60U (K7M-DRT60U)  

 Output point  

 8 points(4 points)  

 12 points(8 points)  

 16 points(12 points)  

 24 points(20 points)  

 Insulation method  

 Relay insulation  

 Rated load voltage/current  

 DC24V / 2A (r/load), AC220V / 2A (COS Ψ = 1)/1 point , 5A / 1COM  

 Min. load Voltage/current  

 DC5V / 1mA  

 Max. load voltage/current  

 AC250V, DC110V  

 Current leakage when off  

 0.1mA (AC220V, 60Hz)  

 Max. On/off frequency  

 1,200 times/hr  

 Surge Absorber  

 None  

 Life  

 Mechanical  

 More than 20,000,000  

 Electrical  

 Rated on/off voltage/current load 100,000 or more  

 AC200V / 1.5A, AC240V / 1A (COSΨ = 0.7) 100,000 or more  

 AC200V / 1A, AC240V / 0.5A (COSΨ = 0.35) 100,000 or more  

 DC24V / 1A, DC100V / 0.1A (L / R = 7ms) 100,000 or more  

 Response time  

 Off → On  

 10 ms or lower  

?

 On → Off  

 12 ms or lower  

 Operation indication  

 LED is on at on status of output  

TR Output:

Model
Specifications  

 Main Unit  

 K7M-DRT/DT20U  

 K7M-DRT/DT30U  

 K7M-DRT/DT40U  

 K7M-DRT/DT60U  

 Output point  

 4 points / 8 point  

 4 points / 12 point  

 4 points / 16 point  

 4 points / 24 point  

 Insulation method  

 Photo coupler insulation  

 Rated load voltage  

 DC12/24V  

 Operation load Voltage  

 DC10.2 ~ 26.4V  

 Max. load current  

 0.5A/1 point (DRT Type P40~P43: 0.1A/1point, DT Type P40~P41 0.1A/1point)  

 Current leakage when off  

 Less than 0.1mA  

 Voltage drop when on  

 Less than DC0.3V  

 Surge Absorber  

 Zener diode  

 Inrush current  

 Less than 4A, 10ms  

 Response time  

 Off → On  

 0.2 ms or lower  

 On → Off  

 0.2 ms or lower  

 Operation indication  

 LED is on at on status of output  






  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: