Description
Power specifications
Rated voltage
AC100-240V
Allowed limits
AC85-264V
Rated frequency
50/60HZ
Power
output power 50w
Allowed instant outage time
Instant outage time less than 10 ms,can continue to work
power fuse
250V 1A
Impulse current
Maximum 15A 5ms below/AC 100V,Maximum 5ms below/AC200V
Power consumption
less than 20W
Sensor power
output power:DC24V 400mA
General Specifications
Environment temperature
0 ~ 55 0C
Storage temperature
-20 ~ 70 0C
Relative humidity
35-85%RH(Non-condensate )
Seismic resistance(DIN rails)
Meet JIS C 0040 standards, 10-57HZ 0.035MM X,Y,Z three direction 10 times each(total 80 minute each)
Meet JIS C 0040 standards, 57-150HZ 4.9M/S2 X,Y,Z three direction,10 times each,(total 80 minute each)
Seismic resistance(install directly)
Meet JIS C 0040 standards, 10-57HZ 0.035MM X.Y.Z three direction ,10 times each(total 80 minute each)
Meet JIS C 0040 standards, 57-150HZ 4.9M/S2 X.Y.Z three direction,10 times each( total 80 minute each)
Impact Resistance
Meet JIS C 0040 standard(147m/S2 action time, 11ms half-sine shock pulse,in X,Y,Z three direction,3 times each)
Noise resistance
Noise voltage 1,000VP-P noise amplitude 1ns 1 frequency 30 ~ 100HZ noise simulation experiment
Withstand Voltage
AC1500V(1 minute),meet JEM-1021 standards,between power port and earth terminal.
Insulation resistance
DC500V insulation tester test above 5MΩ, meet JEM-1021 standards,between power port and earth terminal.
Earth connection
The third kind of earth connection(do not share one place with high voltage system) *1
Operating environment
Close corrosive,combustible gas, No large electrical conductivity dust
RAM
Program storage: 256K
Storage for powerdown mode: 16K
Interface
COM1:RS422(programming interface,HMI common interface)
COM2:RS485,support modbus,HMI,inverter and others device communication(optional)
CAN:use board panel to extend(optional)
Extension module
support to extend
High-speed counting
Single-phase:2-path,up to 200KHZ
AB phase mode:support 1-path AB phase
Software counts
Counter characteristics:2-path 100k,4-path 10k,total pulse 200Khz
Working mode:support 2-path AB phase
High-speed pulse output
Support 2-path,up to 200khz,support PWM,support trapezoid
accelerate and decelerate
Software functions
Interrupt:counter interrupt/native machine IO interrupt/timer interrupt;
IO reflash mode:support END commands/support input output real-time refresh commands/pulse capture;
Programming mode:relay symbol mode+Step ladder diagram(SFC),support interrupt mode;
Real-time clock:bulit-in battery,support long-acting real-time clock running;
Power save:flash permanent preservation,above ten years;
User trapezoid diagram capacity:16K;Arithmetic speed
Basic command:0.1 μs/command
Integer operation:14 μs/command
Instruction specifications
Shell color
Black
Shell Material
ABS Plastic
Shape Size
170×90×88mm
Package size
137*102*97mm
Net weight
0.3kg
Wet weight
0.5kg
No comment |