FX3U-3A-ADP Mitsubishi Analog I/O module 3-channel for FX3S FX3G FX3GC FX3U FX3UC Original Brand NEWFX3U-3A-ADP Mitsubishi PLC Special Adapter Original Brand NEW
Introduction
The FX3U-3A-ADP special adapter for analog input and output (hereinafter called 3A-ADP) is a special adapter that adds to add two analog input points and one analog output point.
Applicable PLC
Model name
Applicability
FX3U Series PLC
Ver. 2.61 or later
FX3UC Series PLC
Ver. 2.61 or later
FX3G Series PLC
Ver. 1.20 or later
FX3GC Series PLC
Ver. 1.40 or later (from first production)
The version number can be checked by monitoring D8001/D8101 as the last three digits indicate it.
Power Supply Specifications
Item
Specification
Conversion circuit
driving power
24V DC +20% / -15%, 90mA
Connect a 24V DC power supply to the terminal block.
Interface driving
power
5V DC, 20mA
5V DC power is supplied from the internal power supply of main unit.
Performance Specifications
Performance Specifications of Analog Input
Item
Specification
Voltage input
Current input
Analog input range
0 to 10V DC (Input resistance: 198.7 k ohm)
4 to 20mA DC
(Input resistance: 250ohm)
Maximum
absolute input
-0.5V, +15V
-2mA, +30mA
Resolution
2.5mV (10V/4000)
5uA (16mA/3200)
Total accuracy
+-0.5% (+-50mV) for full scale
of 10V (when ambient
temperature is 25°C+-5°C)
+-1.0% (±100mV) for full scale
of 10V (when ambient
temperature is 0°C to 55°C)
+-0.5% (+-80uA) for full scale
of 16mA (when ambient
temperature is 25°C+-5°C)
+-1.0% (+-160uA) for full scale
of 16mA (when ambient
temperature is 0°C to 55°C)
Performance Specifications of Analog Output
Item
Specification
Voltage output
Current output
Analog output range
0 to 10 V DC
(External load: 5k ohm to 1M ohm)
4 to 20mA DC
(External load: 500 ohm or less)
Resolution
2.5mV (10V/4000)
4uA (16mA/4000)
Total
accuracy
+-0.5% (+-50mV) for full scale
of 10 V (when ambient
temperature is 25°C+-5 °C)
+-1.0% (+-100mV) for full
scale of 10 V (when ambient temperature is 0°C to 55°C)
If the external load resistance
(Rs) is less than 5k ohm, the accuracy will be increses as shown in the following formula: (Addition will be 100mV per%.)
+-0.5% (+-80uA) for full scale
of 16mA (when ambient
temperature is 25°C±5°C)
+-1.0% (+-160uA) for full
scale of 16mA (when
ambient temperature is 0°C
to 55 °C)
Total accuracy
+-0.5% (+-50mV) for full scale
of 10V (when ambient
temperature is 25°C+-5°C)
+-1.0% (±100mV) for full scale
of 10V (when ambient
temperature is 0°C to 55°C)
+-0.5% (+-80uA) for full scale
of 16mA (when ambient
temperature is 25°C+-5°C)
+-1.0% (+-160uA) for full scale
of 16mA (when ambient
temperature is 0°C to 55°C)