FP0-A21 AFP0480 Panasonic PLC 2 channels input 1 channel output FP0 Analog I/O Unit Original New

prevnext

  • Market price: $ 709.5
  • Shop price: $ 215.0
  • Goods click count: 392
  • Total:
  • Quantity:
Add to cart collect
  

Description

FP0-A21 AFP0480 Panasonic PLC 2 channels input 1 channel output FP0 Analog I/O Unit Original New


Features

Industry's First Battery-less automatic backup of all dataMulti-axis (4-axis) control is available without expansion units.Equipped with RS485 portFastest in its class Ultra-high speed processingLarge capacity independent comment memoryUSB tool port provided as standard equipmentFull-fledged positioning functionsLargest in its class Large capacity programSpecifications

Item

Specifications

FP0-A21

FP0-A80

Number of input points

2 channels / unit

8 channels /unit
Number of input points can be changed 2, 4, 6 and 8 channels.

Input range

Voltage range

0 to 5 V (K0 to K4000) (Note 1)/
-10 to +10 V (K -2000 to K +2000) (Note 1)

0 to 5 V (K0 to K4000) (Note 1)/
-10 to +10 V 
-100 to +100 mV (K -2000 to K +2000) (Note 1)

Current range

0 to 20 mA (K 0 to K 4000) (Note 1)

Resolution

1/4,000 (12 bits)

Conversion speed

1 ms / channel (Note 2)

Overall precision

±1 % FS or less (0 to 55 ? 32 to 131 ?), ±0.6 % F.S or less (25 ? 77 ?)

Input
impedance

Voltage range

1 MΩ or more

Current range

250 Ω

Absolute
maximum input

Voltage range

±15 V

Current range

±30 mA

Insulation method

Between analog input terminal and FP0 internal circuit: optical coupler insulation
(non-insulated between channels)
Between analog input terminal and analog I/O unit external power supply: based on insulation type DC/DC converter
Between analog input terminal and analog output terminal: based on insulation type DC/DC converter

Between analog output terminal and FP0 internal circuit: optical coupler insulation
(non-insulated between channels)
Between analog input terminal and A/D converter unit external power supply: based on insulation-type DC/DC converter

Number of I/O contact points

32 input contact points

Averaging function

None

Can be switched on and off.

Notes:
1) If the analog input value exceeds the upper or lower limit, the digital value will preserve the upper or lower limit.
2) The time shown below is required before the analog data is reflected in the control unit input.

Product List

Product name

Specifications

Product number

Part number

FP0 Analog I/O Unit

Input specifications
Number or channels : 2 channels
Input range : Voltage 0 to 5 V, -10 to +10 V (Resolution: 1/4000)
Current 0 to 20 mA (Resolution: 1/4000)

FP0-A21

AFP0480

Output specifications
Number or channels : 1 channel
Output range : Voltage -10 to +10 V (Resolution: 1/4000)
Current 0 to 20 mA (Resolution: 1/4000)

FP0 A/D Converter Unit

Input specifications
Number or channels : 8 channels
Input range : Voltage 0 to 5 V, -10 to +10 V, -100 to 100 mV (Resolution: 1/4000)
Current 0 to 20 mA (Resolution: 1/4000)

FP0-A80

AFP0401

FP0 D/A Converter Unit

Output specifications
Number or channels : 4 channels
Output range : (Voltage output type) -10 to +10 V (Resolution: 1/4000)
(Current output type) 4 to 20 mA (Resolution: 1/4000)

FP0-A04V

AFP04121

FP0-A04I

AFP04123

FP0 Thermocouple Unit

K, J, T and R thermocouple, Resolution: 0.1°C

FP0-TC4

AFP0420

K, J, T and R thermocouple, Resolution: 0.1°C

FP0-TC8

AFP0421

 














  