No comment |
CPM2AH-40CDR-A Omron PLC New in boxOmron PLC CPM2AH-40CDR-A
Product Description:
The CPM2A brick-style controllers offer one of the most powerful, small-scale control solutions in the industry today. They provide 20, 30, 40 or 60 I/O point CPUs, pulse I/O for position control, multiple communications ports and a powerful instruction set.
1. Expandable Up to 120 I/O Points
2. Peripheral and RS-232C Ports Standard for Direct Connection to Serial Devices and Programming Tools
3. Removable Terminals
4. Synchronized Pulse Control Coordinates Input Devices with Control Devices
5. Auxiliary 24 VDC Supply (AC Type Only)
6. Relay or Transistor Outputs
7. Analog I/O Expansion Modules Available
9. Temperature Sensor Input Expansion Modules Available
10. Real-Time Clock
11. 20 kHz High-Speed Counter Input
12. Two, 10 kHz Pulse Outputs for Position Control Applications
Features:
Item
CPU Units with 20 I/O points
CPU Units with 30 I/O points
CPU Units with 40 I/O points
CPU Units with 60 I/O points
Supply voltagepp y g
AC power
100 to 240 VAC, 50/60 Hz
DC power
24 VDC
Operating voltagep g g range
AC power
85 to 264 VAC
DC power
20.4 to 26.4 VDC
Power consumptionp
AC power
60 VA max.
DC power
20 W max. (See separate table following this one for details.)
Inrush current
AC power
60 A max.
DC power
20 A max.
External power supply (AC power supplies (AC power supplies only)
Supply voltage
24 VDC
Output capacity
300 mA (See notes 1, 2, 3.)
Insulation resistance
20 M? min. (at 500 VDC) between the external AC terminals and protective earth terminals
Dielectric strength
2,300 VAC 50/60 Hz for 1 min between the external AC and protective earth terminals, leakage current: 10 mA max.
Noise immunity
Conforms to IEC61000-4-4, 2 kV (power lines)
Vibration resistance
10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes each (Time coefficient; 8 minutes × coefficient factor 10 = total time 80 minutes)
Shock resistance
147 m/s2 three times each in X, Y, and Z directions
Ambient temperature
Operating: 0° to 55°C Storage: –20° to 75°C
Humidity
10% to 90% (with no condensation)
Atmosphere
Must be free from corrosive gas
Terminal screw size
M3
Power interrupt time
AC power supply: 10 ms min. DC power supply: 2 ms min.
CPU Unit weightg
AC power
650 g max.
700 g max.
800 g max.
1,000 g max.
DC power
550 g max.
600 g max.
700 g max.
900 g max.
Expansion Unit weight
Units with 20 I/O Points: 300 g max. Units with 8 Output Points: 250 g max. Units with 8 Input Points: 200 g max. MAD01 Analog I/O Unit: 150 g max. MAD11 Analog I/O Unit: 250g max. Temperature Sensor Units 250 g max. CompoBus/S I/O Link Units: 200 g max. DeviceNet I/O Link Unit: 200 g max.
No comment |