Your Position: Home > Control System > PLC > Omron PLC > CJ1W-AD04U PLC OMRON 4 input point Process Input Units Original brand new

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

CJ1W-AD04U PLC OMRON 4 input point Process Input Units Original brand new

prevnext

CJ1W-AD04U PLC OMRON 4 input point Process Input Units Original brand new
  • Market price: $ 1689.6
  • Shop price: $ 512.0
  • Goods click count: 293
  • Total:
  • Quantity:
Add to cart collect
  

Description

CJ1W-AD04U PLC OMRON 4 input point Process Input Units Original brand new

Features

Supports a maximum of four inputs in one Unit: resistance thermometer, thermocouple, and DC current/voltage. (The input type is set separately for each input.)

Isolation between input channels prevents unwanted current paths between input channels.

Scaled values are transferred to the CPU Unit in four digits hexadecimal with voltage/current inputs.

Process value alarm with two alarms for each input

Alarm ON-delay timer and hysteresis for process value

Zero/Span adjustment capability during operation

Input error detection

Maximum or minimum process value can be specified for when an input error is detected.

A Unit with fully universal inputs, high-speed and high-resolution (256,000 resolution, 60 ms/ch is available.)

Specification

Product
name

Signal range

Conversion
speed
(resolution)

Accuracy (at ambient
temperature of 25 ° C)

Current
consumption
(A)

Model

Standards

5 V

24 V

Process
Input
Units
(Isolated-
type
Units
with
Universal
Inputs) 

Fully universal inputs:
Pt100, JPt100, Pt1000, K, J,
T, L, R, S, B, 4 to 20 mA,
0 to 20 mA, 1 to 5 V,
0 to 5 V, 0 to 10 V

Conversion
speed:
250 ms/
4 inputs

Accuracy: Platinum resistance
thermometer input: (± 0.3% of
PV or ± 0.8 °C, whichever
is larger) ± 1 digit max.
Thermocouple input: (± 0.3% of
PV or ± 1.5 °C, whichever
is larger) ± 1 digit max. *1
Voltage or current input:
± 0.3% of F.S. ± 1 digit max.

0.32

---

CJ1W-AD04U

UC1, CE, L

Universal inputs:
Pt100 (3-wire), JPt100
(3-wire), Pt1000 (3-wire),
Pt100 (4-wire), K, J, T, E,
L, U, N, R, S, B, WRe5-26,
PL II, 4 to 20 mA,
0 to 20 mA, 1 to 5 V,
0 to 1.25 V, 0 to 5 V,
0 to 10 V, ± 100 mV
selectable range
- 1.25 to 1.25 V,
- 5 to 5 V, - 10 to 10 V,
± 10 V
selectable range,

potentiometer

Resolution
(conversion
speed):
1/256,000
(conversion
cycle: 60 ms/
4 inputs)
1/64,000
(conversion
cycle: 10 ms/
4 inputs)
1/16,000
(conversion
cycle: 5 ms/
4 inputs)

Standard accuracy:
±0.05% of F.S.

0.3

---

CJ1W-PH41U
*2

UC1, CE













  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: