CPM2A-20CDR-A Omron PLC New in box

Omron PLC CPM2A-20CDR-A

Product Description?

Functions as a slave for Device Net.

Equipped with 32 input points and 32 output points for I/O exchange with the master.

International standards: UL, CSA, CE.

Features:

Item

 

CPU Units with 20 I/O points

CPU Units with 30 I/O points

CPU Units with 40 I/O points

CPU Units with 60 I/O points

Supply voltagepp y g

AC power

100 to 240 VAC, 50/60 Hz

DC power

24 VDC

Operating voltagep g g range

AC power

85 to 264 VAC

DC power

20.4 to 26.4 VDC

Power consumptionp

AC power

60 VA max.

DC power

20 W max. (See separate table following this one for details.)

Inrush current

AC power

60 A max.

DC power

20 A max.

External power supply (AC power supplies (AC power supplies only)

Supply voltage

24 VDC

Output capacity

300 mA (See notes 1, 2, 3.)

Insulation resistance

 

20 M? min. (at 500 VDC) between the external AC terminals and protective earth terminals

Dielectric strength

 

2,300 VAC 50/60 Hz for 1 min between the external AC and protective earth termi­nals, leakage current: 10 mA max.

Noise immunity

 

Conforms to IEC61000-4-4, 2 kV (power lines)

Vibration resistance

 

10 to 57 Hz, 0.075-mm amplitude, 57 to 150 Hz, acceleration: 9.8 m/s2 in X, Y, and Z directions for 80 minutes each (Time coefficient; 8 minutes × coefficient factor 10 = total time 80 minutes)

Shock resistance

 

147 m/s2 three times each in X, Y, and Z directions

Ambient temperature

 

Operating: 0° to 55°C Storage: –20° to 75°C

Humidity

 

10% to 90% (with no condensation)

Atmosphere

 

Must be free from corrosive gas

Terminal screw size

 

M3

Power interrupt time

 

AC power supply: 10 ms min. DC power supply: 2 ms min.

CPU Unit weightg

AC power

650 g max.

700 g max.

800 g max.

1,000 g max.

DC power

550 g max.

600 g max.

700 g max.

900 g max.

Expansion Unit weight

 

Units with 20 I/O Points: 300 g max. Units with 8 Output Points: 250 g max. Units with 8 Input Points: 200 g max. MAD01 Analog I/O Unit: 150 g max. MAD11 Analog I/O Unit: 250g max. Temperature Sensor Units 250 g max. CompoBus/S I/O Link Units: 200 g max. DeviceNet I/O Link Unit: 200 g max.

Note: If the external power supply current exceeds the rated current, or there is a short-circuit, the external power supply voltage will drop and PC operation will stop.

If there are 3 CPM1A-MAD11 Units mounted to a CPM2A-60CDR-A, the current for the external power supply must not exceed 200 mA.

  