Your Position: Home > Control System > PLC > Omron PLC > CP1W-20EDT Expansion I/O unit 12 DI 8 DO transistorr PLC Module unit New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

CP1W-20EDT Expansion I/O unit 12 DI 8 DO transistorr PLC Module unit New

prevnext

CP1W-20EDT Expansion I/O unit  12 DI 8 DO transistorr  PLC Module unit New
  • Market price: $ 422.4
  • Shop price: $ 128.0
  • Goods click count: 357
  • Total:
  • Quantity:
Add to cart collect
  

Description

CP1W-20EDT Omron PLC Expansion Module  New in box

Product Description?

Pulse Outputs 

Up to Four Axes Are Standard.
Advanced Power  for High-precision Positioning Control. 

Positioning for Electronic Component Manufacturing Equipment

Sheet Feeding for Vertical Pillow Packer

Pulse Output Function for Up to Four Axes. 

Along with greater precision and more flexibility in multi-product manufacturing, high-speed multi-axis pulse output control responds to the increase in servo applications.

High-speed Counters 

Differential Phases for Up to Four Axes Are Standard.
Easily Handles Multi-axis Control with a Single Unit. 

Main-axis Control for Equipment Such as Textile Machinery or Spinning Machinery

Positioning Conveyance for Equipment Such as Building Material Manufacturing Machinery and Stone-cutting Machinery

 

Specifications 

CP1 Expansion unit

· 8 relay outputs

· 12x 24 VDC inputs, outputs 0.3A 

· Shipping Weight: 0.3 kg

Note:

The above values are for a cold start at room temperature for an AC power supply, and for a cold start for a DC power supply.
A thermistor (with low-temperature current suppression characteristics) is used in the inrush current control circuitry for the AC power supply. The thermistor will not be sufficiently cooled if the ambient temperature is high or if a hot start is performed when the power supply has been OFF for only a short time. In those cases the inrush current values may be higher (as much as two times higher) than those shown above. Always allow for this when selecting fuses and breakers for external circuits.
A capacitor charge-type delay circuit is used in the inrush current control circuitry for the DC power supply. The capacitor will not be charged if a hot start is performed when the power supply has been OFF for only a short time, so in those cases the inrush current values may be higher (as much as two times higher) than those shown above.




  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: