Why buy from us?
We offer competitive prices and quality services!
Ask a Question About This Product
- Stock: In Stock
- Model: CJ1W-SCU41-V1
- Weight: 0.11kg
2. Shipping options include DHL, UPS, FedEx, and EMS.
3. Estimated delivery time for express shipping via DHL, UPS, FedEx, or EMS generally ranges from 3 to 10 business days, depending on the destination country.
4. Please verify your address thoroughly when placing your order.
5. Important for buyers: You are responsible for any tariffs on accessories. To potentially avoid these tariffs, you may choose EMS express shipping.
6. The shipping service is responsible for any accidents, delays, or other issues that may arise.
Returns:
We offer a 14-day return policy. If you wish to return an item, please contact us within 14 days and ensure that the package remains unopened. The buyer is responsible for the shipping costs for both the return and the initial delivery, as well as any applicable customs fees. Once we receive and inspect the product, we will process your refund within 24 hours.
For any quality issues that arise during normal use within the warranty period, we will repair the item free of charge. The buyer is responsible for the return shipping cost, while our company will cover the cost of re-shipping the repaired item.
Omron PLC CJ1W-SCU41-V1
Product Description:
1. Mount a total of up to 16 CPU Bus Units, including these Serial Communications Units, to the CPU Rack or Expansion Racks to create systems with up to 32 serial communications ports.
2. Connect an NT-AL001 RS-232C/RS-442A Link Adapter to the RS-232C port to enable 1:N communications.
3. With the CJ1W-SCU[]2, you can use a faster baud rate (up to 230.4 kbps) and faster data transfer to the CPU Unit to enable connecting to high-speed external devices.
Features:?
Item | Description | ||||||
Device name | Serial Communications Unit | ||||||
Classification | CPU Bus Unit | ||||||
Model number | CJ1W-SCU22 | CJ1W-SCU32 | CJ1W-SCU42 | CJ1W-SCU21-V1 | CJ1W-SCU31-V1 | CJ1W-SCU41-V1 | |
Serial | Port 1 | RS-232C | RS-422A/485 | RS-422A/485 | RS-232C | RS-422A/485 | RS-422A/485 |
Port 2 | RS-232C | RS-422A/485 | RS-232C | RS-232C | RS-422A/485 | RS-232C | |
Protocol | Port 1 | Host Link, protocol macro, Serial Gateway, No- | Host Link, protocol macro, NT Link, or loopback test can be | ||||
Port 2 | |||||||
Number | CPU Unit | None | |||||
CPU Rack | A total of up to 16 Units, including all other | A total of up to 16 Units, including all other CPU Bus Units. | |||||
Expansion | |||||||
Data | Ordinary | Allocated 25 words of the 25 words in the CPU Bus Unit CIO Area (constant data exchange with the CPU Unit) | |||||
Transfer | Of the CPU Bus Unit DM Area, each serial port is allocated 10 words (total 20 words). | ||||||
Simple Backup Function | The CPU Unit's Simple Backup Function can be used to backup the Protocol Macro data in the Serial | ||||||
Current consumption | 280mA+x | 400mA | 360mA+x | 280mA+x | 380mA | 380mA+x | |
Weight | 160g Max. | 120g Max. | 140g Max. | 110g Max. | 110g Max. | 110g Max. | |
General specifications | Conforms to general specifications for CJ Serise. | ||||||
*1.Serial Gateway: The Serial Gateway can also be executed in protocol macro mode.
*2.No-protocol: An external interrupt task can be executed when data is received in No-protocol Mode. If the CJ2H CPU Units with unit version 1.1 or later and CJ2M CPU Units is used, the high-speed communications instructions (DRXDU(261) and DTXDU(262)) can also be used.
*3.The current consumption is for one Serial Communications Unit. When an NT-AL001 Link Adapter is connected to the Serial Communications Unit, power is supplied to the Link Adapter from the Unit. A current consumption of 150 mA must be added for each Link Adapter that is connected. In the above specifications, "x" indicates that 150 mA must be added for each port to which an NT-AL001 Link Adapter is connected to provide the required 5-V power supply.