CJ1W-DA08C PLC OMRON 24VDC I/O 8 point output Original brand new

prevnext

CJ1W-DA08C PLC OMRON 24VDC I/O 8 point output Original brand new
  • Market price: $ 1894.2
  • Shop price: $ 574.0
  • Goods click count: 432
  • Total:
  • Quantity:
Add to cart collect
  

Description

CJ1W-DA021 Omron PLC New in box

Omron PLC CJ1W-DA021

Product Description?

1. Positioning for Electronic Component Manufacturing Equipment

2. Sheet Feeding for Vertical Pillow Packer

3. Along with greater precision and more flexibility in multi-product manufacturing, high-speed multi-axis pulse output control responds to the increase in servo applications.

 Specifications 

Item

CJ1W-DA021

CJ1W-DA041

CJ1W-DA08V

CJ1W-DA08C

CJ1W-DA042V

Unit type

CJ-series Special I/O Unit

Isolation *1

Between I/O and Controller signals:
Photocoupler (No isolation between I/O signals.)

Between I/O and
Controller signals:
Digital isolator (No
isolation between
I/O signals.)

External terminals

18-point detachable terminal block (M3 screws)

Power consumption

5 VDC, 120 mA max.

5 VDC, 140 mA max.

5 VDC, 400 mA max.

External power supply *2

24 VDC +10% -15%,
(inrush current: 20 A max., pulse width: 1 ms min.)

---

140 mA max.

200 mA max.

140 mA max.

170 mA max.

---

Dimensions (mm)

31 × 90 × 65 mm (W × H × D)

Weight

150 g max.

General specifications

Conforms to general specifications for CJ-series Series.

Output
specifi-
cations

Number of analog outputs

2

4

8

8

4

Output signal range *3

1 to 5 V/4 to 20 mA
0 to 5 V
0 to 10 V
- 10 to 10 V

1 to 5 V
0 to 5 V
0 to 10 V
- 10 to 10 V

4 to 20 mA

1 to 5 V
0 to 10 V
- 10 to 10 V

Output impedance

0.5 Ω max. (for voltage output)

0.5 Ω max. (for
voltage output)

---

0.5 Ω max.
(for voltage output)

Max. output current (for
1 point)

12 mA (for voltage output)

2.4 mA (for
voltage output)

---

2 mA
(for voltage output)

Maximum permissible
load resistance

600 Ω (current output)

---

350 Ω

---

Resolution

40,000

4,000/8,000 *8

1 to 5 V

10,000

0 to 10 V

20,000

-10 to 10 V

40,000

Set data

16-bit binary data

Accuracy
*4

25 °C

Voltage output: ± 0.3% of F.S.
Current output: ± 0.5% of F.S.

± 0.3% of F.S.

± 0.3% of F.S.

± 0.3% of F.S.

0 °C to 55 °C

Voltage output: ± 0.5% of F.S.
Current output: ± 0.8% of F.S.

± 0.5% of F.S.

± 0.6% of F.S.

± 0.5% of F.S.

D/A conversion period *5

1.0 ms per point

1.0 ms or 250 μs per point *8

20 μs/1 point,
25 μs/2 points,
30 μs/3 points,
35 μs/4 points

Output
functions

Output hold function

Outputs the specified output status (CLR, HOLD, or MAX) under any of the following
circumstances.
When the Conversion Enable Bit is OFF. *6
In adjustment mode, when a value other than the output number is output during adjustment. *7
When output setting value error occurs or Controller operation stops.
When the Load is OFF.

Scaling

---

Supported only for a conversion
period of 1 ms and resolution of
4,000.
Setting values in any specified
unit within a range of ± 32,000
as the upper and lower limits
allows D/A conversion to be
executed and analog signals to
be output with these values as
full scale.

Setting values in any
specified unit within a
range of ±32,000 as the
upper and lower limits
allows D/A conversion to
be executed and analog
signals to be output with
these values as full scale.

Offset/gain adjustment

Supported

---

Direct conversion

---

D/A conversion is
performed and the output
value is refreshed when
the ANALOG OUTPUT
DIRECT CONVERSION
instruction (AODC) is
executed. This instruction
is supported by the CJ2H-
CPU[][](-EIP) CPU Units
with unit version 1.1 or
later, and CJ2M-CPU[][].
CJ1, NJ501, and CP1H
CPU Units and NSJ
Controllers do not support
direct conversion.

*1.Do not apply a voltage higher than 600 V to the terminal block when performing withstand voltage test on this Unit.

*2.The maximum number of Analog Output Units that can be mounted to one Rack varies depending on the current consumption of the other Units mounted to the Rack.























  