DVP08SN11R Delta PLC 8DO relay output Digital Module Original brand new


Description

 

Thank you for choosing DVP-SS/SA/SX/SC series PLC. The 6 ~ 16 points extension offered by SS/SA/SX/SC series make the maximum digital I/O extension including the MPU reach 128 points. In addition, maximum 8 special modules (AD/DA/PT/TC/XA/RT) are extendable to DVP Slim series.

 

Electrical Specification


Model

Item

DVP08SM11N/

DVP08SM10N

DVP08SN11R/T

DVP08SP11R/T

DVP16SP11R/T

DVP06SN11R

Power Supply Voltage

24VDC (-15%~+20%) (the counter-connection protection towards the DC input power polarity is included)

Motion Specifications

Within 5ms of the momentary power loss, the device will keep on operating

Maximum Power

Consumption

1W

1.5W

1.5W

2W

1.5W

Insulation Resistance

Above 5 MΩ (500VDC between the ground and all the I/O points)

Noise Immunity

ESD(IEC 61131-2, IEC 61000-4-2): 8KV Air Discharge

EFT(IEC 61131-2, IEC 61000-4-4): Power Line: 2KV, Digital I/O: 1KV, Analog &

Communication I/O: 1KV

Damped-Oscillatory Wave: Power Line: 1KV, Digital I/O: 1KV

RS(IEC 61131-2, IEC 61000-4-3): 26MHz~1GHz, 10V/m

Grounding

The diameter of the grounding wire cannot be smaller than that of terminals L and N (if numerous PLCs are used at the same time, make sure that each PLC is grounded respectively to the ground poles)

Vibration/Shock

Immunity

International Standard Regulations: IEC1131-2, IEC 68-2-6 (TEST Fc)/ IEC1131-2 & IEC 68-2-27 (TEST Ea)

Operation/Storage

Environment

Operation: 00C~550C(temperature), 50~95% (humidity), pollution degree: 2; Storage:

-400C~700C (temperature), 5~95% (humidity)

 

Model numbers


Model

Input Unit

Output Unit

Dimensions

(mm)

Weight

(g)

Point

Type

Point

Type

DVP08SP11R

4

DC Type

Sink/Source

4

Relay

25.2 x 90 x 60

141

DVP16SP11R

8

8

162

DVP08SP11T

4

4

Transistor

136

DVP16SP11T

8

8

154

DVP08SM10N

8

100~120VAC

0

None

141

DVP08SM11N

8

DC Type

Sink/Source

0

None

162

DVP08SN11R

0

8

Relay

136

DVP08SN11T

0

8

Transistor

154

DVP06SN11R

0

6

Relay

200




  