PLCAGE: 1746-NIO4I Allen-Bradley PLC 2 Analog Input 2 Analog Current Output New
Features
The NIO4I and NIO4V Analog Combination I/O modules provide 2 input and 2
output channels in a single-slot module. The 1746-NIO4I module contains 2 current
or voltage inputs (user selectable per channel) and 2 current outputs. The
1746-NIO4V module contains 2 current or voltage inputs (user selectable per
channel) and 2 voltage outputs.
Specification
General Specifications for NI4, NIO4I, NIO4V, NO4I, NO4V, FIO4I, FIO4V
Description | Specification |
SLC Communication Format | 16-Bit Two’s Complement Binary |
Field Wiring to Backplane Isolation | 500V dc |
Update Time | 512 µs for all channels in parallel |
Recommended Cable | Shielded Belden #8761 |
Maximum Wire Size | #14 AWG (maximum) |
Terminal Block | Removable |
Location | 1746 chassis |
Calibration | Factory Calibrated |
Noise Immunity | NEMA Standard ICS 2-230 |
Environmental Conditions |
|
Operating Temperature | 0° to +60° C (+32° to +140° F) |
Storage Temperature | -40° to +85° C (-40° to +185° F) |
Relative Humidity | 5 to 95% (non-condensing) |
Backplane Current Specification for NI4, NIO4I, NIO4V, NO4I, NO4V, FIo4I,
and FIO4V
Catalog 1746- | Input Channels per Module | Output Channels per Module | Backplane Current Draw | External 24V dc Power Supply Tolerance | |
5V (max.) | 24V (max.) | ||||
NI4 | 4 differential, voltage or current selectable per channel, not individually isolated | NA | 35 mA | 85 mA | NA |
NIO4I | 2 differential, voltage or current selectable per channel, not individually isolated | 2 current outputs, not individually isolated | 55 mA | 145 mA | NA |
NIO4V | 2 differential, voltage or current selectable per channel, not individually isolated | 2 voltage outputs, not individually isolated | 55 mA | 115 mA | NA |
NO4I | NA | 4 current outputs, not individually isolated | 55 mA | 195 mA | 24V dc ±10% at 195 mA max. (21.6 to 26.4V dc)(1) |
NO4V | NA | 4 voltage outputs, not individually isolated | 55 mA | 145 mA | 24V dc ±10% at 145 mA max. (21.6 to 26.4V dc)(1) |
FIO4I | 2 differential, select V or I per channel, not individually isolated | 2 current outputs, not individually isolated | 55 mA | 150 mA | NA |
FIO4V | 2 differential, select V or I per channel, not individually isolated | 2 voltage outputs, not individually isolated | 55 mA | 120 mA | NA |
(1) Required for some applications if sufficient power is not available from SLC power supply.
1746-NIO4I Allen-Bradley PLC 2 Analog Input 2 Analog Current Output NewIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:service@plcage.com
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.PLCAGE: 1746-NIO4I Allen-Bradley PLC 2 Analog Input 2 Analog Current Output New
Features
The NIO4I and NIO4V Analog Combination I/O modules provide 2 input and 2
output channels in a single-slot module. The 1746-NIO4I module contains 2 current
or voltage inputs (user selectable per channel) and 2 current outputs. The
1746-NIO4V module contains 2 current or voltage inputs (user selectable per
channel) and 2 voltage outputs.
Specification
General Specifications for NI4, NIO4I, NIO4V, NO4I, NO4V, FIO4I, FIO4V
Description
Specification
SLC Communication Format
16-Bit Two’s Complement Binary
Field Wiring to Backplane Isolation
500V dc
Update Time
512 µs for all channels in parallel
Recommended Cable
Shielded Belden #8761
Maximum Wire Size
#14 AWG (maximum)
Terminal Block
Removable
Location
1746 chassis
Calibration
Factory Calibrated
Noise Immunity
NEMA Standard ICS 2-230
Environmental Conditions
Operating Temperature
0° to +60° C (+32° to +140° F)
Storage Temperature
-40° to +85° C (-40° to +185° F)
Relative Humidity
5 to 95% (non-condensing)
Backplane Current Specification for NI4, NIO4I, NIO4V, NO4I, NO4V, FIo4I,
and FIO4V
Catalog
1746-
Input Channels per
Module
Output
Channels per
Module
Backplane Current Draw
External 24V dc
Power Supply
Tolerance
5V (max.)
24V (max.)
NI4
4 differential,
voltage or current
selectable per
channel, not
individually isolated
NA
35 mA
85 mA
NA
NIO4I
2 differential,
voltage or current
selectable per
channel, not
individually isolated
2 current
outputs, not
individually
isolated
55 mA
145 mA
NA
NIO4V
2 differential,
voltage or current
selectable per
channel, not
individually isolated
2 voltage
outputs, not
individually
isolated
55 mA
115 mA
NA
NO4I
NA
4 current
outputs, not
individually
isolated
55 mA
195 mA
24V dc ±10% at 195
mA max.
(21.6 to 26.4V dc)(1)
NO4V
NA
4 voltage
outputs, not
individually
isolated
55 mA
145 mA
24V dc ±10% at 145
mA max.
(21.6 to 26.4V dc)(1)
FIO4I
2 differential, select
V or I per channel,
not individually
isolated
2 current
outputs, not
individually
isolated
55 mA
150 mA
NA
FIO4V
2 differential, select
V or I per channel,
not individually
isolated
2 voltage
outputs, not
individually
isolated
55 mA
120 mA
NA
(1) Required for some applications if sufficient power is not available from SLC power supply.