Your Position: Home > Control System > PLC > AB PLC > 1747-SDN Allen-Bradley PLC DeviceNet Scanner Module Scan I/O Compatible with SLC 5/02 5/03 5/04 and 5/05 processors New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

1747-SDN Allen-Bradley PLC DeviceNet Scanner Module Scan I/O Compatible with SLC 5/02 5/03 5/04 and 5/05 processors New

prevnext

1747-SDN Allen-Bradley PLC DeviceNet Scanner Module Scan I/O Compatible with SLC 5/02 5/03 5/04 and 5/05 processors New
  • Market price: $ 3359.4
  • Shop price: $ 1018.0
  • Goods click count: 279
  • Total:
  • Quantity:
Add to cart collect
  

Description

1747-SDN Allen-Bradley PLC DeviceNet Scanner Module Scan I/O Compatible with SLC 5/02 5/03 5/04 and 5/05 processors New

If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.

PLCAGE: 1747-SDN Allen-Bradley PLC DeviceNet Scanner Module  Scan I/O Compatible with SLC 5/02, 5/03, 5/04, and 5/05 processors New

Features

Slave Mode

Poll

Strobe

Change of State

Change of state enables the scanner module to perform a scan:

* whenever a network data change occurs.

* at a user-configurable heartbeat rate.

Cyclic I/O

Cyclic I/O allows you to instruct the scanner module to perform a scan at a specific send rate. Because data is only sent at a periodic rate, this feature increases system performance by reducing network traffic.

Specification

Attribute

Value

Module location

SLC 5/02 or later chassis

Module default

Node Address – 63

Baud Rate – 125 Kbps

Power consumption

    - Backplane current

    - DeviceNet


5V DC, 500 mA

24V DC, 90 mA Class 2

Isolation voltage

30V (continuous), Basic Insulation Type

Tested at 500V AC for 60 s, DeviceNet to backplane

Temperature, operating

IEC 60068-2-1 (Test Ad, Operating Cold),

IEC 60068-2-2 (Test Bd, Operating Dry Heat),

IEC 60068-2-14 (Test Nb, Operating Thermal Shock): (0°C to +60°C)

Temperature, non-operating

IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),

IEC 60068-2-2 (Test Bc, Unpackaged Nonoperating Dry Heat),

IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): (-40°C to +185°C)

Relative humidity

IEC 60068-2-30 (Test Db, Unpackaged Damp Heat):

5…95% non-condensing

Vibration

IEC60068-2-6 (Test Fc, Operating):

2 g @10…500 Hz

Shock

IEC60068-2-27:1987, Test Ea (Unpackaged shock, ES#002)

Operating — 30 g

Non-operating — 50 g

Emissions

CISPR 11:

Group 1, Class A (with appropriate enclosure)

ESD immunity

IEC 61000-4-2:

6 kV contact discharges

8 kV air discharge

Radiated RF immunity

IEC 61000-4-3:

10 V/m with 1 kHz sine-wave 80% AM from 80…2000 Mhz

EFT/B immunity

IEC 61000-4-4:

+2 kV at 5 kHz on communication ports

Surge transient immunity

IEC 61000-4-5:

±2 kV line-earth(CM) on communications ports

Conducted RF immunity

IEC 61000-4-6:

10 Vrms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz

Magnetic field immunity

IEC 61000-4-8

30A/m long duration at 50 Hz

Enclosure type rating

None (open style)





  