No comment |
>
Control System >
PLC >
AB PLC >
1747-SDN Allen-Bradley PLC DeviceNet Scanner Module Scan I/O Compatible with SLC 5/02 5/03 5/04 and 5/05 processors New1747-SDN Allen-Bradley PLC DeviceNet Scanner Module Scan I/O Compatible with SLC 5/02 5/03 5/04 and 5/05 processors NewIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.PLCAGE: 1747-SDN Allen-Bradley PLC DeviceNet Scanner Module Scan I/O Compatible with SLC 5/02, 5/03, 5/04, and 5/05 processors New
Features
Slave Mode
Poll
Strobe
Change of State
Change of state enables the scanner module to perform a scan:
* whenever a network data change occurs.
* at a user-configurable heartbeat rate.
Cyclic I/O
Cyclic I/O allows you to instruct the scanner module to perform a scan at a specific send rate. Because data is only sent at a periodic rate, this feature increases system performance by reducing network traffic.
Specification
Attribute
Value
Module location
SLC 5/02 or later chassis
Module default
Node Address – 63
Baud Rate – 125 Kbps
Power consumption
- Backplane current
- DeviceNet
5V DC, 500 mA24V DC, 90 mA Class 2
Isolation voltage
30V (continuous), Basic Insulation Type
Tested at 500V AC for 60 s, DeviceNet to backplane
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock): (0°C to +60°C)
Temperature, non-operating
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bc, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock): (-40°C to +185°C)
Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged Damp Heat):
5…95% non-condensing
Vibration
IEC60068-2-6 (Test Fc, Operating):
2 g @10…500 Hz
Shock
IEC60068-2-27:1987, Test Ea (Unpackaged shock, ES#002)
Operating — 30 g
Non-operating — 50 g
Emissions
CISPR 11:
Group 1, Class A (with appropriate enclosure)
ESD immunity
IEC 61000-4-2:
6 kV contact discharges
8 kV air discharge
Radiated RF immunity
IEC 61000-4-3:
10 V/m with 1 kHz sine-wave 80% AM from 80…2000 Mhz
EFT/B immunity
IEC 61000-4-4:
+2 kV at 5 kHz on communication ports
Surge transient immunity
IEC 61000-4-5:
±2 kV line-earth(CM) on communications ports
Conducted RF immunity
IEC 61000-4-6:
10 Vrms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz
Magnetic field immunity
IEC 61000-4-8
30A/m long duration at 50 Hz
Enclosure type rating
None (open style)
No comment |