1756-PA75 Allen-Bradley PLC 120/240V AC-Input Power Supply New1756-PA75 Allen-Bradley PLC 120/240V AC-Input Power Supply NewIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.PLCAGE: 1756-PA75 Allen-Bradley PLC 120/240V AC-Input Power Supply New
Features
*All regulated voltages necessary for any ControlLogix® module to operate in the chassis
*Limited hold-up time for fluctuations in incoming line power
*Enables orderly system shutdown by signaling modules in the chassis of imminent voltage failure
*Provides all of the regulated voltages necessary for any ControlLogix module to operate in the chassis.
*Provides limited hold-up time for fluctuations in incoming line power.
*Signals modules in chassis of imminent voltage failure for orderly system shutdown.
*Redundant power supplies offer:
-Automatic chassis load sharing between the redundant power supplies.
-LED indicators for visual operating status of the pair.
-Solid state relay for system recognition of supply status when wired to an input module.
Specification
Attribute
1756-PA72/C
1756-PA75/B
Input voltage range
85…265V AC
Input voltage, nom
120V/240V AC
Input frequency range
47…63 Hz
Input power, max
100VA/100 W
Output power, max
75 W @ 0…60 °C (32…140 °F)(2)
Power consumption
25 W @ 0…60 °C (32…140 °F)
Power dissipation
85.3 BTU/hr
Hold-up time
5 cycles @ 85V AC, 50/60 Hz
6 cycles @ 120V AC, 50/60 Hz
6 cycles @ 200V AC, 50/60 Hz
6 cycles @ 240V AC, 50/60 Hz
Inrush current, max
20 A
Current capacity at 1.2V DC
1.5 A
Current capacity at 3.3V DC
4 A
Current capacity at 5.1V DC
10 A
13 A
Current capacity at 24V DC
2.8 A
Overcurrent protection, max
User-supplied 15 A(
Fusing
Non-replaceable fuse is soldered in place
Transformer load, max
100VA
Isolation voltage
250V (continuous), reinforced insulation type
Type tested @ 3500V DC for 60 s, power input-to-backplane
Weight, approx.
0.95 kg (2.10 lb)
Chassis
1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17
Conductor screw torque
0.8 N•m (7 lb•in)
North American temperature code
T4
Enclosure type rating
None (open-style)
Environmental Specifications - 1756 Standard AC Power Supplies
Attribute
1756-PA72/C, 1756-PA75/B
Temperature, operating
IEC 60068-2-1 (Test Ad, Operating Cold),
IEC 60068-2-2 (Test Bd, Operating Dry Heat),
IEC 60068-2-14 (Test Nb, Operating Thermal Shock)
0…60 °C (32…140 °F)
Temperature, storage
IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),
IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),
IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)
-40…85 °C (-40…185 °F)
Relative humidity
IEC 60068-2-30 (Test Db, Unpackaged Nonoperating Damp Heat)
5…95% noncondensing
Vibration
IEC 60068-2-6 (Test Fc, Operating)
2 g @ 10…500 Hz
Shock, operating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
30g
Shock, nonoperating
IEC 60068-2-27 (Test Ea, Unpackaged Shock)
50g
Emissions
CISPR 11: Group 1, Class A
ESD immunity
IEC 61000-4-2
6kV contact discharges
8kV air discharge
Radiated RF immunity
IEC 61000-4-3
10V/m with 1 kHz sine-wave 80% AM from 80... 2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz
3V/m with 1kHz sine-wave 80% AM from 2000...2700 MHz
EFT/B immunity
IEC 61000-4-4
+/- 4 kV at 5 kHz on signal ports
Surge transient immunity
IEC 61000-4-5
+/- 1 kV line-line (DM) and +/- 2 kV line-earth (CM) on signal ports
Conducted RF immunity
IEC 61000-4-
10Vrms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz
Oscillatory surge withstand
IEEE C37.90.1
3 kV
Voltage variation
IEC 61000-4-11
30% dips for 1 period at 0° and 80° on AC supply ports
60% dips for 5 and 50 periods on AC supply ports
+/- 10% fluctuations for 15 min on AC supply ports
>95% interruptions for 250 periods on AC supply ports