1756-PA75 Allen-Bradley PLC 120/240V AC-Input Power Supply New

prevnext

1756-PA75 Allen-Bradley PLC 120/240V AC-Input Power Supply New
  • Market price: $ 2715.9
  • Shop price: $ 823.0
  • Goods click count: 170
  • Total:
  • Quantity:
Add to cart collect
  

Description

1756-PA75 Allen-Bradley PLC 120/240V AC-Input Power Supply New

If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.

PLCAGE: 1756-PA75 Allen-Bradley PLC 120/240V AC-Input Power Supply New

Features

*All regulated voltages necessary for any ControlLogix® module to operate in the chassis

*Limited hold-up time for fluctuations in incoming line power

*Enables orderly system shutdown by signaling modules in the chassis of imminent voltage failure

*Provides all of the regulated voltages necessary for any ControlLogix module to operate in the chassis.

*Provides limited hold-up time for fluctuations in incoming line power.

*Signals modules in chassis of imminent voltage failure for orderly system shutdown.

*Redundant power supplies offer:

   -Automatic chassis load sharing between the redundant power supplies.

-LED indicators for visual operating status of the pair.

-Solid state relay for system recognition of supply status when wired to an input module.

Specification

Attribute

1756-PA72/C

1756-PA75/B

Input voltage range

85…265V AC

Input voltage, nom

120V/240V AC

Input frequency range

47…63 Hz

Input power, max

100VA/100 W

Output power, max

75 W @ 0…60 °C (32…140 °F)(2)

Power consumption

25 W @ 0…60 °C (32…140 °F)

Power dissipation

85.3 BTU/hr

Hold-up time

5 cycles @ 85V AC, 50/60 Hz

6 cycles @ 120V AC, 50/60 Hz

6 cycles @ 200V AC, 50/60 Hz

6 cycles @ 240V AC, 50/60 Hz

Inrush current, max

20 A

Current capacity at 1.2V DC

1.5 A

Current capacity at 3.3V DC

               4 A

Current capacity at 5.1V DC

10 A

 

13 A

Current capacity at 24V DC

2.8 A

Overcurrent protection, max

User-supplied 15 A(

Fusing

Non-replaceable fuse is soldered in place

Transformer load, max

100VA

Isolation voltage

250V (continuous), reinforced insulation type

Type tested @ 3500V DC for 60 s, power input-to-backplane

Weight, approx.

0.95 kg (2.10 lb)

Chassis

1756-A4, 1756-A7, 1756-A10, 1756-A13, 1756-A17

Conductor screw torque

0.8 N•m (7 lb•in)

North American temperature code

T4

Enclosure type rating

None (open-style)

Environmental Specifications - 1756 Standard AC Power Supplies

Attribute

1756-PA72/C, 1756-PA75/B

Temperature, operating

IEC 60068-2-1 (Test Ad, Operating Cold),

IEC 60068-2-2 (Test Bd, Operating Dry Heat),

IEC 60068-2-14 (Test Nb, Operating Thermal Shock)

0…60 °C (32…140 °F)

Temperature, storage

IEC 60068-2-1 (Test Ab, Unpackaged Nonoperating Cold),

IEC 60068-2-2 (Test Bb, Unpackaged Nonoperating Dry Heat),

IEC 60068-2-14 (Test Na, Unpackaged Nonoperating Thermal Shock)

-40…85 °C (-40…185 °F)

Relative humidity

IEC 60068-2-30 (Test Db, Unpackaged Nonoperating Damp Heat)

5…95% noncondensing

Vibration

IEC 60068-2-6 (Test Fc, Operating)

2 g @ 10…500 Hz

Shock, operating

IEC 60068-2-27 (Test Ea, Unpackaged Shock)

30g

Shock, nonoperating

IEC 60068-2-27 (Test Ea, Unpackaged Shock)

50g

Emissions

CISPR 11: Group 1, Class A

ESD immunity

IEC 61000-4-2

6kV contact discharges

8kV air discharge

Radiated RF immunity

IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from 80... 2000 MHz

10V/m with 200 Hz 50% Pulse 100% AM @ 900 MHz

10V/m with 200 Hz 50% Pulse 100% AM @ 1890 MHz

3V/m with 1kHz sine-wave 80% AM from 2000...2700 MHz

EFT/B immunity

IEC 61000-4-4

+/- 4 kV at 5 kHz on signal ports

Surge transient immunity

IEC 61000-4-5

+/- 1 kV line-line (DM) and +/- 2 kV line-earth (CM) on signal ports

Conducted RF immunity

IEC 61000-4-

10Vrms with 1 kHz sine-wave 80% AM from 150 kHz...80 MHz

Oscillatory surge withstand

IEEE C37.90.1

3 kV

Voltage variation

IEC 61000-4-11

30% dips for 1 period at 0° and 80° on AC supply ports

60% dips for 5 and 50 periods on AC supply ports

+/- 10% fluctuations for 15 min on AC supply ports

>95% interruptions for 250 periods on AC supply ports

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: