Your Position: Home > Control System > PLC > Delta PLC > PLC DC24V 16 DI 12 DO transistor PNP Delta DVP28SV11S2 New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

PLC DC24V 16 DI 12 DO transistor PNP Delta DVP28SV11S2 New

prevnext

PLC DC24V 16 DI 12 DO transistor PNP Delta DVP28SV11S2 New
  • Market price: $ 1006.5
  • Shop price: $ 305.0
  • Goods click count: 267
  • Total:
  • Quantity:
Add to cart collect
  

Description

DVP28SV11S2 Delta PLC 24VDC 16DI 12DO transistor(PNP) output Functional Original brand new


General introduction

The SV/SV2 is a 28-point (16 inputs + 12 outputs)/24-point (10 inputs + 12 outputs + 2 analog input channels) PLC

MPU, offering various instructions and with 16k (SV)/30k (SV2) steps program memory, able to connect to all Slim type series extension models, including digital I/O (max. 512 points), analog modules (for A/D, D/A conversion and temperature measurement) and all kinds of high-speed extension modules. 4 groups of high-speed (200 kHz) pulse outputs (and two axes which generate 10 kHz outputs in 24SV2) and 2 two-axis interpolation instructions satisfy all kinds of applications. DVP-SV/SV2 is small in size and easy to install.

Electrical Specifications

Model

Item

DVP28SV11R

DVP28SV11R2

DVP28SV11T

DVP24SV11T2

DVP28SV11T2

DVP28SV11S2

Power supply

voltage

24VDC (-15% ~ 20%) (with counter-connection protection on the polarity

of DC input power) 

Inrush current

Max. 2.2A@24VDC

Fuse capacity

2.5A/30VDC, Polyswitch

Power

consumption

6W

Insulation

resistance

> 5M ohm (all I/O point-to-ground: 500VDC)

Noise immunity

ESD (IEC 61131-2, IEC 61000-4-2): 8kV Air Discharge

EFT (IEC 61131-2, IEC 61000-4-4): Power Line: 2kV, Digital I/O: 1kV,

Analog & Communication I/O: 1kV

Damped-Oscillatory Wave: Power Line: 1kV, Digital I/O: 1kV

RS (IEC 61131-2, IEC 61000-4-3): 26MHz ~ 1GHz, 10V/m

Grounding

The diameter of grounding wire shall not be less than that of the wiring terminal of the power. (When PLCs are in use at the same time, please make sure every PLC is properly grounded.)

Operation /

storage

Operation: 0ºC ~ 55ºC (temperature); 5 ~ 95% (humidity); 

pollution degree 2

Storage: -25ºC ~ 70ºC (temperature); 5 ~ 95% (humidity)

Agency approvals

UL508

European community EMC Directive 89/336/EEC and Low Voltage

Directive 73/23/EEC

Vibration / 

shock immunity

International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/IEC61131-2 & IEC 68-2-27 (TEST Ea)

Weight (g)

260

260

240

240

230


  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: