No comment |
TSXPAY262 Schneider PLC NEWIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.Schneider PLC TSXPAY262
Product description:
Main:
Range of product Modicon Premium Automation platform
Product or component
type
Preventa safety module
Discrete input number 1 reset PB input IEC 1131 Type 1
1 feedback loop input IEC 1131 Type 1
1 reset PB monitoring input IEC 1131 Type 1
1 double or single contact selection input IEC 1131
Type 1
12 emergency stop or limit switch discrete inputs
IEC 1131 Type 1
Safety outputs 2 NO safety relay AGCDO gold plated volt free output
Standards CSA 22-2 specific requirements (PLC)
EN/IEC 60204-1 machine electrical equipment
EN/IEC 61131-2 specific requirements (PLC)
EN/ISO 12100 machine electrical equipment
EN 1088 machine safety parts of control systems
EN 418 emergency stop equipment
EN 954 machine safety parts of control systems
ISO 13849-11 category 4 machine safety parts of
control systems
ISO 13850 emergency stop equipment
ISO 14119 machine safety parts of control systems
UL 508 specific requirements (PLC)
Pr IEC 61508 (SIL 3) machine safety parts of control
Systems
Complementary:
[Us] rated supply voltage 24 V DC
Supply voltage limits 19.2...30 V
Activation threshold < 20 V
Short circuit protection 1 A gG external IEC 947-5-1 on power supply
4 A gG external IEC 947-5-1 on safety relay outputs
Isolation voltage 4000 V III 2
Discrete input logic Positive
Inrush current ≤ 0.5 A
Iso between input and earth 500 Vrms 50/60 Hz 60 s
Power dissipation in W < 5 W
[Ue] rated operational voltage 17...127 V DC relay output
19...250 V AC relay output
Rated power in VA 60 VA 24 V AC-15 inductive
120 VA 48 V AC-15 inductive
280 VA 110 V AC-15 inductive
550 VA 220 V AC-15 inductive
Rated power in W 60 W 24 V DC-13 inductive 100 ms
[Ithe] conventional enclosed thermal current ≤ 2.5 A
Minimum output current ≥ 30 mA
Response time on output < 10 ms
Isolation between output and earth 300 V DIN VDE 0110 part 2
1500 Vrms 50/60 Hz 60 s
Safety acquisition Monitor external power supply of the module
Read enable inputs
Read feedback loop
Read status of the 24 inputs
Read the safety outputs control
Local signalling 28 LEDs diagnostic of safety system
Electrical connection 1 connector SUB-D 44 pins for connecting the safety system input
1 connector removable screw terminal block 6 pins for connecting the safety output
Cable cross section 0.2...2.5 mm² without cable end safety output circuit
1.5 mm² with cable end safety output circuit
Current consumption < 150 mA 5 V DC
≤ 200 mA 24 V DC
No comment |