Your Position: Home > Control System > PLC > Delta PLC > PLC 1 channel weighing module DVP01LC-SL Delta New

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

PLC 1 channel weighing module DVP01LC-SL Delta New

prevnext

PLC 1 channel weighing module DVP01LC-SL Delta New
  • Market price: $ 620.4
  • Shop price: $ 188.0
  • Goods click count: 610
  • Total:
  • Quantity:
Add to cart collect
  

Description

DVP01LC-SL Delta PLC 24VDC 24bit-resolution Load Cell Module Original brand new

Electrical Specifications

Load cell module

Voltage output

Rated power supply voltage/ power consumption

24 VDC (-15 to +20%) / 3W

Voltage Boundary

18 to 31.2 VDC

Max. current consumption

125 mA

Input signal range

± 40 mVDC

Sensibility

+5 VDC +/-10%

Internal resolution

24 bits

Communication port

RS-232, RS-485

Applicable sensor type

4-wire or 6-wire strain gauge

Temperature coefficient span

≤ ± 50 ppm/K v. E

Temperature coefficient zero point

≤ ± 0.4 μV/K

Linearity error

≤ 0.02%

Response time

2, 10, 20, 40, 80 ms × channels

4 measuring ranges

0 to 1 mV/V, 0 to 2 mV/V, 0 to 4 mV/V, 0 to 6mV/V

Max. distance for connecting to load cell

100 M

Max. current output

5VDC * 300 mA

Permitted load cell resistance

40 to 4,010 Ω

Common mode rejection (CMRR @50/60 Hz)

≥100dB

Dynamic value filter

Setting range: K1 to K5

Average value filter

Setting range: K1 to K100

Isolation method

500 VAC between digital circuits and Ground

500 VAC between analog circuits and Ground

500 VAC between analog circuits and digital circuits

 

Series connection to DVP-PLC MPU

Connectable to the left side of MPU, numbered from 100 to 107 according to the position of module from the closest to farthest to MPU.

Operation / storage temperature

 

Operation: 0 to 55°C (temp.), 50 to 95% (humidity), pollution degree 2

Storage: -25 to 70°C (temp.), 5 to 95% (humidity)

 

Vibration / shock immunity

International standards: IEC61131-2, IEC 68-2-6 (TEST Fc)/

IEC61131-2 & IEC 68-2-27 (TEST Ea)

 

*Complying with DIN1319-1, the tolerance of measured value should be <=0.05% under 200C + 10K temperature range.

*When the corrected ambient temperature and the actual temperature have a difference of more than 10°C, it is suggested that you re-correct it.

Product Profile & Dimensions

 

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: