TM2DDO8UT Schneider PLC ModuleIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.Schneider PLC Module TM2DDO8UT
Product description:
Complementary
Discrete input logic Positive logic (sink) fast input
Sink or source (positive/negative) input
Number of common point 1 input
1 solid state output
4 fast input
4 relay output
Sensor power supply 19.2...30 V DC
Voltage state1 guaranteed >= 15 V input/fast input
Current state 1 guaranteed >= 2 mA input/fast input
Voltage state 0 guaranteed <= 5 V input/fast input
Current state 0 guaranteed <= 1.5 mA input/fast input
Discrete input current 10.4 mA input
8 mA fast input
Input impedance 2.3 kOhm input
3 kOhm fast input
Response time 0.25 ms solid state output
3 ms input
300 ns fast input
Configurable filtering time 0.004 ms fast input
0.4 ms fast input
1 ms fast input
2 ms fast input
4 ms fast input
Anti bounce filtering 0 ms configurable input/fast input
1.5 ms configurable input/fast input
12 ms configurable input/fast input
4 ms configurable input/fast input
2
Input frequency <= 100 kHz fast input (counter mode)
<= 100 kHz fast input (normal mode)
<= 100 kHz input
Cable length <= 10 m shielded cable fast input (counter mode)
<= 30 m fast input (normal mode)
<= 30 m input
<= 30 m relay output
<= 30 m solid state output
Isolation between channels and internal logic 500 V AC relay output
500 V DC solid state output
Isolation between channels 500 V for group of 2 fast inputs
500 V solid state output
None input
Discrete output logic Positive logic (source)
Output voltage limits 19.2...30 V solid state output
250 V relay output
30 V relay output
Discrete output current 2 A relay output Q4...Q8
20...500 mA solid state output
5 A relay output Q9
Output frequency <= 100 kHz solid state output
Leakage current < 2 mA solid state output
[Ures] residual voltage < 2 V solid state output
Tungsten load < 3 W solid state output
Short-circuit protection With solid state output
Overvoltage protection With solid state output
Overload protection With solid state output
Minimum load 10 mA 5 V DC relay output
Contact resistance <= 50 μOhm
Load current 2 A 240 V AC resistive <= 600 cyc/mn relay output Q4...Q8
2 A 30 V DC resistive <= 600 cyc/mn relay output Q4...Q8
5 A 240 V AC inductive <= 1800 cyc/mn relay output Q9
5 A 30 V DC inductive <= 1800 cyc/mn relay output Q9
Mechanical durability >= 20000000 cycles relay output
Electrical durability >= 100000 cycles relay output Q4...Q8
>= 500000 cycles relay output Q9
Input/Output number <= 136 removable screw terminal block with I/O expansion module
<= 192 spring terminal block with I/O expansion module
<= 248 HE-10 connector with I/O expansion module
Supply voltage limits 85...264 V
Inrush current <= 35 A
Power consumption in W <= 25 W 100 V
<= 42 W 264 V
Insulation resistance > 10 MOhm at 500 V, between I/O and earth terminals
> 10 MOhm at 500 V, between supply and earth terminals
Exact time for 1 Kinstruction 0.3 ms 70 % Boolean + 30 % fixed arithmetic
Execution time per instruction 0.42 μs arithmetic INT word LD and ST
0.439 μs arithmetic INT word +, -, x operations
0.459 μs arithmetic DINT double-word LD and ST
0.506 μs arithmetic DINT double-word +, -, x operations
0.648 μs arithmetic REAL floating LD and ST
0.971 μs Boolean
5111 μs arithmetic REAL floating +, -, x operations
7.25 μs arithmetic REAL floating by operation
Exct time for event task <= 1.75 ms arithmetic REAL floating
>= 0.75 ms arithmetic INT word
0.95 ms arithmetic DINT double-word
System overhead 0.15 ms master task (PWM, frequency meter)
0.15 ms master task (simple counting)
0.2 ms master task (PTO)
0.35 ms master task (advanced counting)
0.9 ms master task (I/O)
Input output assignment Reading/Writing I/O on base
Reading/Writing I/O on extension modules
Application structure 1 configurable freewheeling/cyclic master task
2 configurable freewheeling/cyclic/event auxiliary tasks
32 levels of priority between tasks
4 interrupt tasks
3
Realtime clock With 10 s/month at 25 °C
Integrated connection type 1 isolated serial link female RJ45 Modbus master/slave RTU/ASCII, character
mode or SoMachine-Network RS232/RS485 1.2...115.2 kbit/s (115.2 kbit/s by default)
Supply Serial link supply 5 V 200 mA
Positioning functions HSC reflex 4 100 Hz
Counting input number 8 100 kHz 32 bits
Complementary function Event processing
PID
Marking CE
Local signalling 1 LED RUN
1 LED Batt
1 LED module error (ERR)
1 LED per channel I/O state
1 LED PWR
1 LED SL1
Electrical connection 1 connector mini B USB 2.0 for a programming terminal
1 removable screw terminal block (10 terminals) for connecting the 6 preactuators
(output)
1 removable screw terminal block (12 terminals) for connecting the sensors (fast
inputs)
1 removable screw terminal block (6 terminals) for connecting the 4 preactuators
(output)
1 removable screw terminal block (7 terminals) for connecting the sensors (inputs)
1 removable screw terminal block for connecting the 100-240 V AC power supply
Product weight 0.56 kg
Environment
Immunity to microbreaks 10 ms
Dielectric strength 1500 V for 1 minute, between I/O and earth terminals
1500 V for 1 minute, between supply and earth terminals
Product certifications CSA
CTick
GOST
UL
Ambient air temperature for operation -10...55 °C
Ambient air temperature for storage -40...70 °C
Relative humidity 95 % without condensation
IP degree of protection IP20
Pollution degree <= 2
Operating altitude 0...2000 m
Storage altitude 0...3000 m
Vibration resistance 1 gn 3.5 mm (f= 5...150 Hz)
Shock resistance 15 gn for 11 ms