E6A2-CW5C 200P?R 0.5M OMRON Encoder NEW

OMRON Encoder E6A2-CW5C 200P?R

Product Description:

Incremental model

External diameter of 25 mm.

Resolution of up to 500 ppr.  

Specifications:

Model

E6A2-CW3E

E6A2-CW3C

E6A2-CW5C

Power supply voltage

5 VDC -5% to 12 V +10%,

12 VDC -10% to 24 VDC +15%,

ripple (p-p): 5% max.

ripple (p-p): 5% max.

Current consumption *1

30 mA max.

20 mA max.

Resolution

100, 200, 360, 500

(pulses/rotation)

Output phases

Phases A and B

Output configuration

Voltage output

NPN open-collector output

Output capacity

Output resistance: 2 kΩ

Applied voltage: 30 VDC max.

Output current: 20 mA max.

Sink current: 30 mA max.

Residual voltage: 0.4 V max.

Residual voltage: 0.4 V max.

(Output current: 20 mA max.)

(at sink current of 30 mA)

Maximum response

30 kHz

frequency *2

Phase difference

Phase difference between phases A and B: 90°±45°

between outputs

Output duty factor

---

Rise and fall times of

1.0 μs max. (Cable length:

1.0 μs max. (Cable length: 500 mm,

output

500 mm, Sink current: 10 mA)

Control output voltage: 5 V, Load resistance: 1 kΩ)

Starting torque

1 mNm max.

Moment of inertia

1 × 10-7 kgm2 max.

Shaft

Radial

10 N

loading

Thrust

50 N

Maximum permissible

5,000 r/min

speed

Ambient temperature

Operating: -10 to 55°C (with no icing), Storage: -25 to 80°C (with no icing)

range

Ambient humidity range

Operating/storage: 35% to 85% (with no condensation)

Insulation resistance

20 MΩ min. (at 500 VDC) between current-carrying parts and case

Dielectric strength

500 VAC, 50/60 Hz for 1 min between current-carrying parts and case

Vibration resistance

Destruction: 10 to 55 Hz, 1.5-mm double amplitude for 2 hours each in X, Y, and Z directions

Shock resistance

Destruction: 500 m/s2 3 times each in X, Y, and Z directions

Degree of protection *3

IEC 60529 IP50

Connection method

Pre-wired Models (Standard cable length: 500 mm)

Material

Case: Aluminum alloy, Main unit: Aluminum, Shaft: SUS420J2, Mounting Bracket: Galvanized iron

Weight (packed state)

Approx. 35 g

Accessories

Coupling, Servo Mounting Bracket (provided with the E6A2-CWZ[]), Hexagonal wrench, Instruction manual

 

 

  