No comment |
E6B2-CWZ6C 2500P/R OMRON encoder
Incremental outer diameter φ40 encoder
the generic type of φ40
? corresponds to the power supply voltage DC5 ~ 24V
(Open collector output)
? The outer diameter of φ40 equipped with the resolution of 2000P / R
? with the origin position Z is relatively simplistic display
? shaft load, radial 30N thrust to 20N
? attached to the reverse connection, load short-circuit protection circuit to improve the reliability
(Also available in the linear drive output)
Model
E6B2-CWZ6C
E6B2-CWZ5B
E6B2-CWZ3E
E6B2-CWZ1X
Project
Supply voltage
DC5V-5 ~ 24V +15%
Less than 5% of the pulse (p-p)DC12V-10% ~ 24V +15%
Less than 5% of the pulse (p-p)DC5V-12V to +10%
Less than 5% of the pulse (p-p)DC5V ± 5%
Less than 5% of the pulse (p-p)Current consumption * 1
70mA following
80mA following
130mA following
Resolution (pulses / rotation)
10?20?30?40?50?60?
100?200?300?360?
400?500?600?720?
800?1,000?1,024?1,200?
1,500?1,800?2,000100?200?360?500?
600?1,000?2,00010?20?30?40?50?60?
100?200?300?360?
400?500?600?1,000?
1,200?1,500?1,800?2,00010?20?30?40?50?60?
100?200?300?360?
400?500?600?1,000?
1,024?1,200?1,500?
1,800?2,000Output phase
A?B?Z Phase
A?A?B?B?Z?ZPhase
Output phase difference
Phase A, B, phase difference of 90 ± 45 ° C (1/4 ± 1/8T)
Output mode
NPN open collector output
PNP open collector output
Voltage output (NPN output)
Linear drive * 2
Output capacity
Below the applied voltage: DC30V
Synchronous current: 35mA max.
Residual voltage: 0.4V
(At sink current of 35mA)Below the applied voltage: DC30V
Synchronous current: 35mA max.
Residual voltage: 0.4V
(At sink current of 35mA)Output resistance: 2kΩ
Synchronous current: 20mA max.
Residual voltage: 0.4V
(At sink current of 20mA)AM26LS31 considerable product
Output current
H: IO =-20mA
L-bit: IS = 20mA
Output voltage VO = 2.5V
VS = 0.5V belowThe highest frequency response *3
100kHz
50kHz
100kHz
The output rise and fall time
1μs following
Control the output voltage: 5V
Load resistor 1kΩ
Cable length 2m1μs following
(Cable length: 2m synchronous current: 10mA)0.1μs following
Cable length: 2m
IO =-20mA, IS = 20mAStarting torque
0.98mN·m following
Moment of inertia
1×10?6kg·m2 following
Shaft allows the force
Radial direction
30N
Axial
20N
Allows the maximum speed
6,000r/min
Protection circuit
Load short-circuit protection, power supply reverse wiring protection
Ambient temperature range
Action: -10 ~ +70 ? save: -25 ~ +85? (with no icing)
Ambient humidity range
Action, save: 35 ~ 85% RH (no condensation)
Insulation resistance
20MΩ or more (500 VDC megger) charging the Ministry of the overall housing
Withstand Voltage
Voltage AC500V 50/60Hz 1min between charging and case
Vibration (durable)
10 ~ 500Hz complex amplitude of 2mm or 150 m/s2, X-, Y, Z each direction scan 11min 3 scan
The impact of (durable)
1,000 m/s2 X, Y,, and Z directions for three times
Protection structure * 3
Enclosure rating IEC IP50
Connection
Pre-wired (standard cable length 500mm)
Material shell
Shell
ABS
Ministry of
the base metalAluminum
Axis
SUS420J2
Weight (packaged)
About 100g
Attachment
Coupling, hex wrench, manual
* 1 When power flows through the red flow of about 9A.(Time: about 0.3ms)
* The line driver output is based on the RS-422A data transmission circuit, through the double-stranded wire hunt for long-distance transmission. (Built-in AM26LS31 fairly products)
* 3. Electricity highest response speed according to the resolution and the highest response frequency requirements.
Therefore, when the rotation exceeds the maximum response speed, electrically can not trace the signal.
No comment |