No comment |
E6C3-CWZ5GH 500P/R OMRON encoderIncremental outer diameter φ50 (solid type)
Durability and ease of use!
? using sealed bearings,
A IP65f drip oil constructor
? enhance the resistance axis load performance.
Radial 80N axial 50N
Ratings / Performance
Model
E6C3-CWZ5GH
E6C3-CWZ3EH
E6C3-CWZ3XH
Project
Supply voltage
DC12?10??24?15?V
Less than 5% of the pulse (p-p)DC5?5??12?10?V
Less than 5% of the pulse (p-p)Current consumption * 1
100mA following
Resolution (pulses / rotation)
100?200?300?360?500?600?720?800?1,000?1,024?1,200?1,500?1,800?2,000?2,048?2,500? 3,600
Output phase
A?B?Z Phase
A?A?B?B?Z?Zphase
Output mode
Open collector output * 2
Voltage output (NPN output)
Open collector output * 3
Output capacity
Output voltage: VH = Vcc-3V (IO = 30mA) VL = 2V (IO =-30mA) output current: ± 30mA
Output resistance: 2kΩ
Output current: 35mA
Residual current: 0.7VAM26LS31 considerable product output current H: IO =-10mAL: IS = 10mA output voltage of the VO = 2.5V VS = 0.5V below
The highest frequency response *4
125kHz (Z-phase reset room for 65kHz)
Output phase difference
Phase A, B, phase difference of 90 ± 45 ° C (1/4 ± 1/8T)
The output rise and fall time
1μs below (cable length: 2m output current: 30mA)
1μs below (cable length: 2m output current: 35mA)
Below 1ms (wire: 2m IO =-10mA, IS: 10mA)
Starting torque
At room temperature: 10mN · m, at low temperatures: 30mN · m
Starting torque
At room temperature: 10mN · m, at low temperatures: 30mN · m
Moment of inertia
2.0 × 10-6kg · m2 (500P / R below 1.9 × 10-6kg · m2)
Shaft allows the force
Radial direction
80N
Axial
50N
Allows the maximum speed
5,000r/min
Protection circuit
Load short-circuit protection, power supply reverse wiring protection
Ambient temperature range
Work: -10 ~ +70 ? save: -25 ~ +85? (with no icing)
Ambient humidity range
Work, save: 35 ~ 85% RH (no condensation)
Insulation resistance
20MΩ or more (500 DC megger) charging the Ministry of the overall housing
Withstand Voltage
Voltage AC500V 50/60Hz 1min between charging and case
Vibration (durable)
10 ~ 500Hz complex amplitude of 2mm or 150 m/s2, X-, Y, Z each direction scan 11min 3 scan
The impact of (durable)
1,000 m/s2 X, Y,, and Z directions for three times
Protection structure * 3
IEC60529 specification IP65 (JEM specifications IP65f anti-drop · oil) * 5
Connection
Pre-wired (standard cable length 1m)
Material shell
Shell
Aluminum
Ministry of
the base metalAluminum
Axis
SUS303
Weight (packaged)
About 300g
Attachment
Manual
Note:
* 1 When power flows through the swash 9A. (Time: about 0.1ms)
* 2 complementary outputs, said output circuit, the NPN and PNP output transistors. According to the output signal "H", "L"
The two kinds of output transistors cross each other to the "ON", "OFF" action. When used, the positive supply, the OV points do not pull,
Pull down the complementary output is the output current outflow or inflow of two kinds of action. Characterized by the rise of the signal drop fast wire extend over long distances.
Connection with the machine open-collector input (NPN, PNP).
* 3 The line driver output is based on the RS-422A data transmission circuit. Long-distance transmission through the double-stranded cable.
(AM26LS31 fairly products)
* 4. Electrical response speed according to the resolution of the highest frequency response requirements. Electrical response speed (r / min) × 60
Therefore, when the rotation exceeds the maximum response speed, electrically can not trace the signal.
* 5. JEM1030: for the period 1991
No comment |