No comment |
>
Control System >
Inverter >
Single Phase 220V 3.1A 0.4KW 0.5HP TECO Inverter S310-2P5-H1D NEW
Product Specifications
Single/Three Phase, 200~240V model
S310-xxx-XXX
2P5
201
202
Horsepower (HP)
0.5
1
2
Max Applicable Motor Output (KW)
0.4
0.75
1.5
Rated Output Current(A)
3.1
4.2
7.5
Rated Capacity(KVA)
0.88
1.60
2.9
Max. Input Voltage
Single Phase: 200~240V +10%-15%, 50/60Hz+-5%
Max.Output Voltage
Single Phase: 200~240V
Input Current(A)
5.4
10.4
16
Net Weight(KG)
0.97
1.07
Net. Weight(KG)Keypad
1.0
1.1
Allowable momentary power loss time
(second)
1.0
1.0
2.0
General Specifications
Item
S310
Control
V/F
Frequency Control
Range
0.01~400.00Hz
Setting Resolution
Digital: 0.01Hz, Analog: 0.06Hz/60Hz(10bits)
Keypad Setting
Set directly with “up” “down” keys or the VR on the keypad
Display Function
Five digital LED and status indicator: display frequency/Inverter parameter/Fault Log/Program Version
External Signal setting
1. External potentiometer 0-10V/0-20mA
2. Provides up/down controls, speed control or automatic procedure control with multifunctional contacts on the terminal block(TM2)
Frequency Limit Function
Upper/lower frequency limits
General Control
Carrier frequency
1~12KHz
V/F pattern
6 fixed patterns, 1 programmable curve
Acc/Dec control
Acc/Dec time(0.1~3,600 seconds)
Multifunction analog output
4 functions (refer to description on 2-12)
Multifunction input
10 functions
Multifunction output
6 functions
Other Functions
Momentary Power Loss Restart, Overload Detection, 8 preset speeds, 2/3-wire Control, torque boost, Slip Compensation, Frequency Upper/Lower Limit, Modbus slave and PC/PDA Link, Auto Restart.
Communication Control
1. Control by RS485
2. One to one or one to many (RS485 ONLY) control.
3. BAUD RATE/STOP BIT/PARITY/bit can be set
Braking Torque
About 20%, standard model the specified external braking resistors can provide 100%
Operation temperature
14-1200F(-10~500C)
Storage temperature
4-1400F(-20~600C)
Humidity
0-95% Relative Humidity (Non-condense)
Vibration
1G(9.8m/S2)
Enclosure
IP20
Protective Functions
FUSE protection
The motor stops after FUSE melt
Over Voltage
200V class: DC Voltage>410V
Under Voltage
200V class: DC Voltage<190V
Momentary Power Loss Restart
Restart can be initiated with spin start
Other Function
Over torque detection, error contact control, reverse prohibit, prohibit for direct start after power up and error recovery.
Wiring
No comment |