Your Position: Home > Control System > Inverter > Single/Three-phase 200V 7.5A 1.5KW 2HP TECO Inverter N2-202-H NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

Single/Three-phase 200V 7.5A 1.5KW 2HP TECO Inverter N2-202-H NEW

prevnext

Single/Three-phase 200V 7.5A 1.5KW 2HP TECO Inverter N2-202-H NEW
  • Market price: $ 778.8
  • Shop price: $ 236.0
  • Goods click count: 159
  • Total:
  • Quantity:
Add to cart collect
  

Description

 

 

Product Specifications

1/ 3 Phase 200-240 Volts

N2-xxx—xxx

2P5

201

202

203

205

208

210

215

220

230

Horse Power

1/2

 

1

2

3

5

7.5

10

15

20

30

Rated Motor KW

0.4

0.75

1.5

2.2

3.7

5.5

7.5

11

15

22

Rated Current (A)

3.1

4.5

7.5

10.5

17.5

26

35

49

64

87

Output (KVA)

1.2

1.7

2.9

4.0

6.7

9.9

13.3

18.7

24.4

33.2

Input Voltage Max.

(1 / 3 Phase) (200~240 Volts +-10%) (50/60Hz +-5%) (5 h.p. & above 3 Phase Only)

Output Voltage Max.

3 Phase 200 ~ 240 (proportional to input voltage)

IP20 Weight (Kg)

1.4

1.4

2.5

4.0

4.0

6.8

7.1

12.3

12.5

13.8

Power Loss

Ride Through (s)

1

1

2

2

2

2

2

2

2

2

3 Phase 380 ~ 480 Volts

N2-xxx—xxx

401

402

403

405

408

410

415

420

430

Horse Power

1

 

2

3

5

7.5

10

15

20

30

Rated Motor KW

0.75

1.5

2.2

3.7

5.5

7.5

11

15

22

Rated Current (A)

2.3

3.8

5.2

8.8

13

17.5

25

32

48

Output (KVA)

1.7

2.9

4.0

6.7

9.9

13.3

19.1

24.4

36.6

Input Voltage Max

( 3 Phase 380 ~ 480 Volts +- 10%) (50/60Hz +- 5%)

Output Voltage Max.

3 Phase 380 ~ 480 Volts (proportional to input voltage)

IP20 Weight (Kg)

2.4

2.5

3.8

4.0

7.0

7.3

12.3

12.5

13.5

Power Loss

Ride Through (s)

1

1

2

2

2

2

2

2

2

Functional Specification

Control

Characteristics

Carrier frequency

1 - 12 K

Frequency Control Range

0.1 – 400 Hz

Frequency Accuracy

Digital: 0.01%  (-10 ~ 40 °C); Analog: 0.4%  (25+-10 °C)

Frequency Resolution

0.01 Hz with computer or PLC control, 0.1 Hz with keypad control when freq. 

above 100 Hz

Frequency Setting Signal

(0-5VDC)  (0-10VDC)  (4-20mA) (0-20mA)

Accel / Decel Time

0.1-3600 SEC with  (2) S-curves

Braking Torque

About 20% (built-in Braking transistor)

V/F Pattern

18 patterns, one curve programmable

Protection Function

Instantaneous Over Current

Approx. 200% rated current

Overload

T-verter: 150% / 1 minute

Motor Overload Protection

Electronic thermal overload relay

Over voltage

200V series: (DC bus voltage exceeds 427V) 

400v series: (DC bus voltage exceeds 854V)

Under voltage

200V series: (DC bus voltage drops < 200V)           

400v series: (DC bus voltage drops < 400V)

Momentary Power Loss

0~2 seconds: The T-verter can be restarted using the speed search feature  

Heat Sink Fin Overheat

Protected by thermister

Ground Fault

Electronic circuit protection

Operation Conditions

Input Signal

Operation signals

Forward/Reverse operation, by keypad or hardwire contact, multiple individual commands

Reset

Released protection while the protective function is operating

Multifunction Input

Refer to function illustration in Fn_56

Output Signal

Multifunction Output

Refer to function illustration in Fn_61

  Fault output

250VAC 1A, 30VDC 1A or less

Built-in Function

Frequency reference bias/gain; up/lower limit; manual torque boost; frequency meter calibrating gain; auto restart attempt; skip frequency; S-curve ACCEL/DECEL; Carrier frequency adjust.(1-12KHz) 

Communication link function

Digital operator monitor

Frequency command, output frequency, speed, output current, output voltage, P-N bus voltage, rotating direction  

Analog Output Monitor

Analog output (0-10V), possible to select output frequency & setting freq. & output voltage & P-N bus voltage

Environmental

Location

Indoor (protected from corrosive gas and dust)  

Ambient Temperature

-10 degrees ~ 40 degrees © 50 degrees with cover removed  

Humidity

0-95%(non condensing)

Vibration

0.5G

Enclosure

IP20 / IP65 (NEMA4)

EMC

EN50081-1, EN50082-2 (with optional filter)

LVD

EN50178

UL

UL 508C

N2-205 and above capacity are not CE complied

Wiring

 

  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: