No comment |
>
Control System >
Inverter >
1 Phase 220V 2.6A 0.4KW 0.5HP TECO Inverter L510-2P5-H1-N NEW
Model Lists
Model
Supply
voltage
(Vac)
Frequency
(Hz)
(Hp)
(KW)
Model
VR
Built-in
Filter
NPN
PNP
Built-in
None
L510-1P2-H1-N
1ph,
100~120V
10%/-15%
50/60Hz
0.25
0.2
V
V
V
L510-1P5-H1-N
0.5
0.4
V
V
V
L510-101-H1-N
1
0.75
V
V
V
L510-2P2-H1F-P
1ph,
200~240V
+10%/-15%
0.25
0.2
V
V
L510-2P5-H1F-P
0.5
0.4
V
V
L510-201-H1F-P
1
0.75
V
V
L510-202-H1F-P
2
1.5
V
V
L510-203-H1F-P
3
2.2
V
V
L510-2P2-H1-N
0.25
0.2
V
V
V
L510-2P5-H1-N
0.5
0.4
V
V
V
L510-201-H1-N
1
0.75
V
V
V
L510-202-H1-N
2
1.5
V
V
V
L510-203-H1-N
3
2.2
V
V
V
L510-2P2-H3-N
3ph,
200~240V
+10%/-15%
0.25
0.2
V
V
V
L510-2P5-H3-N
0.5
0.4
V
V
V
L510-201-H3-N
1
0.75
V
V
V
L510-202-H3-N
2
1.5
V
V
V
L510-203-H3-N
3
2.2
V
V
V
Environment
The environment will directly affect the proper operation and the life span of the inverter, so install the inverter in an environment complying with the following conditions:
Protection
Protection
class
IP20
Suitable environment
Operating
temperature
-10~500C
If several inverters are installed in the same control panel, please make sure the placement is conductively to vent heat.
Storage
temperature
-20~600C
Humidity
95% RH or less (no condensation)
Notice prevention of inverter freezing up.
Shock
20HzBelow1G(9.8m/s²)
20~50Hz 0.6G(5.88m/s²)
Installation sites
Avoid direct sunlight.
Avoid exposure to rain or moisture.
Avoid oil mist and salinity.
Avoid corrosive liquid and gas.
Avoid dust, lint fibers, and small metal filings.
Avoid electromagnetic interference (soldering machine, power machine).
Keep away from radioactive and flammable materials.
Avoid vibration (stamping, punching machine). Add a vibration-proof pad if the situation cannot be avoided.
Exterior
Product Specifications
110VClass: Single phase
Model: L510-XXX -H1-N
1P2
1P5
101
Horse power (HP)
0.25
0.5
1
Suitable motor capacity (KW)
0.2
0.4
0.75
Rated output current (A)
1.8
2.6
4.3
Rated capacity (KVA)
0.68
1.00
1.65
Input voltage range(V)
Single Phase: 100~120V(+10%-15%),50/60HZ
Output voltage range(V)
Three phase 0~240V
Input current (A)
9.5
13
19
Inverter N.W (KG)
Inverter with filter (KG)
0.62
0.68
0.72
Allowable momentary power loss time
(S)
1.0
1.0
1.0
Enclosure
IP20
220VClass: Single phase
Model: L510-XXX –H3-N
2P2
2P5
201
202
203
Horse power (HP)
0.25
0.5
1
2
3
Suitable motor capacity (KW)
0.2
0.4
0.75
1.5
2.2
Rated output current (A)
1.8
2.6
4.3
7.5
10.5
Rated capacity (KVA)
0.68
1.00
1.65
2.90
4.00
Input voltage range(V)
Single Phase: 200~240V(+10%-15%),50/60HZ
Output voltage range(V)
Three phase 0~240V
Input current (A)
4.9
7.2
11
15.5
21
Inverter N.W (KG)
Inverter with filter (KG)
0.65
0.71
0.67
0.73
0.67
0.73
1
1.25
1.05
1.3
Allowable momentary power loss time
(S)
1.0
1.0
1.0
2.0
2.0
Enclosure
IP20
220VClass: Three phase
Model: L510-XXX –H3-N
2P2
2P5
201
202
203
Horse power (HP)
0.25
0.5
1
2
3
Suitable motor capacity (KW)
0.2
0.4
0.75
1.5
2.2
Rated output current (A)
1.8
2.6
4.3
7.5
10.5
Rated capacity (KVA)
0.68
1.00
1.65
2.90
4.00
Input voltage range(V)
THREE Phase: 200~240V(+10%-15%),50/60HZ
Output voltage range(V)
Three phase 0~240V
Input current (A)
3.0
4.0
6.4
9.4
12.2
Inverter N.W (KG)
Inverter with filter (KG)
0.61
0.61
0.66
0.95
1
Allowable momentary power loss time
(S)
1.0
1.0
1.0
2.0
2.0
Enclosure
IP20
F: means built-in filter
No comment |