No comment |
>
Control System >
Inverter >
SV040iG5-2 LS AC Drive Inverter Starvert Series iG5 3 Phase 5.4HP 4KW 4000W 200~230V New free shippingSV040iG5-2 LS AC Drive Inverter Starvert Series iG5 3 Phase 5.4HP 4KW 4000W 200~230V New free shippingIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574- 88333153
We will quote you our best price to you in 24hours.Features:
Selectable V/f, sensorless vector control
Motor parameter Auto-tuning
Powerful torque at overall speed range
0.1 ~ 400Hz frequency output
-15% ~ +10% input voltage margin
Fault history: Last 5 faults
0~10Vdc / -10 ~ +10Vdc analog input
IP20 enclosure, UL Type 1 (Option)
Selectable manual/automatic torque boost
Selectable PNP/NPN input signal
2nd motor control and parameter setting
Built-in Dynamic braking transistor as standard
Enhanced process PID control
Built-in RS485 (LS Bus / Modbus RTU) communication
Cooling fan On/Off control & Easy change
Remote control using external keypad * RJ45 cable(Optional)
Upgraded functions:
Sleep & Wake-up (Energy savings)
KEB(Kinetic Energy Buffering) protection
Low leakage PWM algorism
Monitoring & commissioning PC based software tool (Drive View)
Specifications:
3 Phase 200V
Drive Type (SV_ _ _iG5-_)
004-2
008-2
015-2
022-2
037-2
040-2
Max.
capacity 1)(HP)
0.5
1
2
3
5
5.4
(kW)
0.37
0.75
1.5
2.2
3.7
4
Output
ratingCapacity (kVA) 2)
1.1
1.9
3
4.5
6.1
6.5
FLA (A)
3
5
8
12
16
17
Frequency
0~400 [Hz]
Voltage
200~230V 3)
Input
ratingVoltage
3 phase 200~230 VAC (±10%)
Frequency
50~60 [Hz] (±5%)
Weight (kg)
1.2
1.2
1.8
2.1
2.2
2.2
Braking torque
Braking circuit
On board
Average braking torque
20% (with optional external braking resistor : 100%, 150%)
Max. continuous braking time
15 seconds
Max. duty
0 ~ 30 % ED
Cooling method
Natural
Forced air cooling
Enclosure
IP00
*1) Indicates the maximum applicable capacity when using 4 pole LG standard motor.
*2) Rated capacity ( 3*V*I) is based on 220V for 200V class and 440V for 400V class.
*3) Maximum output voltage will not be greater than the input voltage. Output voltage less than the input voltage can be set.
Applications:
Converting, Fan, Pump, Food processing machine, Electric shutter, Dryer, Running machine, Overheat, Commercial washing machine, Grinder, Textile machine, Material handling machine, Centrifuge, Elevator door, Tooling machine
Other hot items of this LS 3 phase 200~230V iG5 series inverter for above applications:
SV004iG5-2
SV004iG5-2 LS AC Drive Inverter Starvert Series iG5 3 Phase 0.5HP 0.37KW 370W 200~230V New
SV008iG5-2
SV008iG5-2 LS AC Drive Inverter Starvert Series iG5 3 Phase 1HP 0.75KW 750W 200~230V New
SV015iG5-2
SV015iG5-2 LS AC Drive Inverter Starvert Series iG5 3 Phase 2HP 1.5KW 1500W 200~230V New
SV022iG5-2
SV022iG5-2 LS AC Drive Inverter Starvert Series iG5 3 Phase 3HP 2.2KW 2200W 200~230V New
SV037iG5-2
SV037iG5-2 LS AC Drive Inverter Starvert Series iG5 3 Phase 5HP 3.7KW 3700W 200~230V New
SV040iG5-2
SV040iG5-2 LS AC Drive Inverter Starvert Series iG5 3 Phase 5.4HP 4KW 4000W 200~230V New
No comment |