Your Position: Home > Control System > Inverter > SJ200-004NFE Frequency Inverter SJ200 series 3-phase 200 ~ 240V AC NEW

  Categories

Control System
Motion Control System
LCD Screen Panel
Instrumentation
Low Voltage
Transducer/Sensor
  

Service



Email: [email protected]
Tel: 0086-574-88333153

View History

   

SJ200-004NFE Frequency Inverter SJ200 series 3-phase 200 ~ 240V AC NEW

prevnext

SJ200-004NFE Frequency Inverter SJ200 series 3-phase 200 ~ 240V AC NEW
  • Market price: $ 1122.0
  • Shop price: $ 340.0
  • Goods click count: 191
  • Total:
  • Quantity:
Add to cart collect
  

Description

SJ200-004NFE HITACHI Frequency inverter SJ200 series 3-phase 200 ~ 240V AC NEW

If you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.

Features:

              Capacity Range: 0.2 – 7.5 kW

              Global Standards to CE, UL, c-UL, cTick and CSA

              Integrated RS485 Interface

              Internal Brake Chopper

              Sensorless Vector Control (SLV)

              Integrated EMC-Filter

              200% Starting Torque

              Built-in Potentiometer

              PID Control

              Automatic Voltage Regulation

              Motor Thermistor Input

Specifications:

Inverter SJ200

200V-Series

400V-Series

002

004

005

007

011

015

022

004

007

015

022

030

040

055

075

 

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

NFEF2

Applicable motor (kW)

0.2

0.4

0.55

0.75

1.1

1.5

2.2

0.4

0.75

1.5

2.2

3.0

4.0

5.5

7.5

Rated output current (A)

1.6

2.6

3.0

4.0

5.0

8.0

11.0

1.5

2.5

3.8

5.5

7.8

8.6

13.0

16.0

Input supply phase 

Single phase / three phase

Three phase

 

Rated input voltage 

200 VAC –10 % ~ 240 VAC +10 % 50/60 Hz ±5 %

380 VAC -10 % ~ 460 VAC +10 % 50/60 Hz ±5 %

Rated output voltage 

Three phase 200 ~ 240VAC (corresponds to input voltage)

Three phase 380 ~ 460 VAC (corresponds to input voltage)

Output frequency range

0.5 ~ 400 Hz

Frequency accuracy

Digital command: ±0.01 % of maximum frequency

(at 25 °C ±10 °C)

(Analogue command: ±0.1 % of maximum frequency)

Frequency setting resolution Digital setting

Digital setting: 0.1 Hz Analogue setting: maximum frequency / 1000

Voltage/frequency characteristic

Intelligent sensorless vector control, constant or reduced torque

Overload capacity (current)

150 % for 60 seconds (once every 10 minutes)

Acceleration/deceleration time

 0.01 ~ 3000 s in selectable linear and non-linear mode (second acceleration/deceleration usable)

Starting torque (using SLV)

 200 % or more

180 % or more

Braking torque

Dynamic braking,

approx. 100 %

approx. 100 %

approx. 20 %

approx. 100 %

approx.70 %

approx.20 %

feedback to capacitor (50 Hz)

approx. 100 %

approx. 100 %

approx. 150 %

approx. 100 %

approx. 100 % approx

DC injection braking

Variable operating frequency, time and braking force can be set

Inputs

Frequency setting

Digital operator

Settings using keys or potentiometer

External signals

0-10 VDC (input impedance 10k ohm) 4-20 mA (input impedance 250 ohm) potentiometer 1k-2k ohm, 2 W

Forward / reverse run

Digital operator

Via keys RUN (for start) and STOP/RESET (for stop) (default setting: forward run)

External signals

Forward run/stop, Reverse run/stop

Intelligent input terminals

  FW: Forward run start/stop RV: Reverse run start/stop CF1–CF4: Multistage speed JG: Jogging command AT: Analogue current input selection

programmable as, i.e.

2CH: 2nd accel./decel. time FRS: Free run stop EXT: External trip USP: USP function RS: Reset SFT: Software lock PTC: Thermal protection

DB: Ext. DB input SET: 2nd setting active UP: Acceleration (remote) DWN: Decelerate (remote)

Outputs

Intelligent output terminals

FA1/FA2: Frequency arrival signal RUN: Motor running signal OL: Overload signal OD: Deviation signal at PID control AL: Alarm signal

programmable as, i.e.

Frequency and current monitoring

0-10 VDC, 8 bit

PID loop operation

Air velocity, temperatur etc.

Other functions

Autotuning, automatic voltage regulation, analog input calculate function, automatic carrier frequency reduction, frequency jump,
output frequency display, trip history monitoring, carrier frequency setting, PID control, automatic torque boost, USP function,
2nd setting function, ON/OFF control of cooling fan

Standards

CE, UL, cUL, c-Tick

Thermal motor protection

Thermistor input PTC (intelligent input 5)

Protection functions

Overcurrent, overvoltage, undervoltage, electronic thermal, temperature abnormality, ground fault at starting , overload, CT error, BRD error

Environmental
conditions

Ambient temperature

 -10 ~ 50 °C; > 40 °C current

Storage temperature and humidity

?-25 ~ 60 °C

 

20 ~ 90 % RH (no dew condensation)

Options

Remote operator, copy unit, cable for digital operator, reactor for improving power factor, noise filter, ProDrive software

Protection class

IP20

Overall weight (approx.) in kg

0.7

0.8

1.8

1.8

2.8

1.3

1.7

2.8

3.8

5.7

 






  

User Comment

No comment
Username: Anonymous user
E-mail:
Rank:
Verification code: captcha
Content: