No comment |
VM06-0550N4 Sanken Inverter SRMCO-VM06 series NEWIf you need more than 10pcs and want to get better wholesale price, please feel free to contact us by following:
email:[email protected]
Tel:0086-574-88333153
We will quote you our best price to you in 24hours.VM06-0040-N4 Sanken Inverter SRMCO-VM06series NEW
The High-end Inverter
Overview:
The SAMCO-vm06 Series of general-purpose inverters boasts revolutionary performance born from Sanken's superlative technological capabilities.
To meet diversified needs, the SAMCO-vm05 Series offers a powerful array of features, including dual-rated specifications selectable to best suit the intended application, the industry's first software customization function, and control algorithms provided as standard.
Dual-rated specifications for cost reduction
Two types of rated specifications - H characteristic and P characteristic can be selected according to the load status, for a wider range of standard applicable motors and substantial cost reduction (200 V type STB Series).
Industry's first software customize function
Dedicated functions can be created by adding various types of software, according to the customer's requirements. Users can also perform program changes and upgrades following purchase.
Control algorithms for various types of applications provided as standard
Control algorithms for diverse applications, such as winding control, multiple pump drive control and fixed-time inching, are provided as standard. This can be used as a dedicated inverter to meet diversified system needs.
Operability and communication functions developed with ease of use
The RS-232C interface, allowing direct connection to personal computers, and the RS-485 interface, effective in operation management in a system, are provided as standard.
Expandability with PG feedback
Vector control operation is realized through a PG feedback board (option).
Specifications:
Item
Specification
Model?VM06? 200V
0015
0022
0037
0055
0075
0110
Output specification
Mode B
Light
loadStandard applicable motor [KW]
1.5
2.2
3.7
5.5
7.5
11
Rated capacity [KVA] *1
2.7
3.7
5.8
8.5
11.4
16.8
Rated current [A]
7.0
9.6
15.1
22.3
30
44.0
Overload current rating *2
120%-1min
Output frequency range *3
0.05-240Hz?Starting frequency 0.05-60Hz variable?
Mode A
Heavy
loadStandard applicable motor [KW]
0.8
1.5
2.2
3.7
5.5
7.5
Rated capacity [KVA] *1
1.9
3
4.3
6.7
9.1
12.6
Rated current [A]
5.1
8
11.2
17.6
24
33
Overload current rating *2
150%-1min
Output frequency range *3
0.05-590Hz?Starting frequency 0.05-60Hz variable?
Rated output voltage *4
3φ 200V-220V
Input power supply
Voltage & Frequency
3φ 200V-230V ? 50/60Hz
Allowable fluctuation
Voltage: -15%?+10% Frequency: ±5% Voltage unbalance:within 3%
Power supply impedance
1% and above?Use optional reactor if less than 1%?
Mode B
Light
loadRequired power capacity [KVA] *5
2.3
3.1
4.9
7.7
10.4
16.4
Input current [A]
*6With DCL
5.9
8.1
12.8
20.3
27.3
43.1
Without DCL
9.1
12.5
19.6
31.2
42
61.6
Mode A
Heavy
loadRequired power capacity [KVA] *6
1.5
2.6
3.6
5.7
8.3
11.4
Input current [A]*6
With DCL
4.3
6.8
9.5
14.9
21.9
30
Without DCL
6.6
10.4
14.6
22.9
33.6
46.2
Protective structure
Totally enclosed?IP20?
Cooling method
Forced air cooling
Approximate weight
4kg
6kg
7kg
Carrier frequency
Sine wave PWM?carrier frequency 1k-14kHz??7
DC reactor
option
*1 Rated capacity at the output voltage of 220V
*2 One minute is allowed every 10 minutes
*3 During vector control, PG sensorless is 0.25Hz-240Hz /PG sensor is 0.05Hz-240Hz (depends on the number of poles)
*4 Output voltage cannot exceed power supply voltage
*5 Vary with the impedance changes of the power supply including a DC reactor
*6 Vary with the impedance of the power supply
*7 The maximum value of carrier frequency varies with the inverter capacity mode and operation status.
Item
Specification
Model?VM06? 400V
0015
0022
0040
0055
0075
0110
0150
0185
Output specification
Mode B
Light
loadStandard applicable motor [KW]
0.8
1.5
2.2
4
5.5
7.5
11
15
Rated capacity [KVA] *1
1.7
2.8
4.2
6.2
8.7
11.8
17.3
22.2
Rated current [A] *2
3
4
6
9
12.6
17
25
32
Overload current rating *3
150%-1min
Output frequency range *4
0.05-590Hz?Starting frequency 0.05-60Hz variable?
Mode A
Heavy
loadStandard applicable motor [KW]
1.5
2.2
4
5.5
7.5
11
15
18.5
Rated capacity [KVA] *1
2.8
4.2
6.2
8.7
11.8
17.3
22.2
26.3
Rated current [A] *2
4
6
9
12.6
17
25
32
38
Overload current rating *3
120%-1min
Output frequency range *4
0.05-590Hz?Starting frequency 0.05-60Hz variable?
Rated output voltage *5
3φ 380V-4600V
Input power supply
Voltage & Frequency
3φ 380V-460V ? 50/60Hz
Allowable fluctuation
Voltage: -15%?+10% Frequency: ±5% Voltage unbalance: within 3%
Power supply impedance
1% and above?Use optional reactor if less than 1%?
Mode B
Light
loadRequired power capacity [KVA] *5
2.4
3.8
5.8
8.7
12.1
16.4
24.2
31
Input current [A]
*6With DCL
2.1
3.6
5.5
8.2
11.5
15.5
24.5
31.5
Without DCL
3.5
5.6
8.4
12.6
17.6
23.8
35
44.8
Mode A
Heavy
loadRequired power capacity [KVA] *6
3.8
5.8
8.7
12.1
16.4
24.2
31
36.8
Input current [A]*6
With DCL
3.6
5.5
8.2
11.5
15.5
24.5
31.4
37.2
Without DCL
5.6
8.4
12.6
17.6
23.8
35
44.8
53.2
Protective structure
Totally enclosed?IP20?
Cooling method
Forced air cooling
Approximate weight
4kg
6kg
7kg
Carrier frequency
Sine wave PWM?carrier frequency 1k-14kHz??9
DC reactor
option
*1 Rated capacity at the output voltage of 400V
*2 When input voltage is 400VAC and above, the rated current will be decreased according to the output power
*3 One minute is allowed every 10 minutes
*4 During vector control, PG sensorless is 0.25Hz-240Hz /PG sensor is 0.05Hz-240Hz (depends on the number of poles)
*5 Output voltage cannot exceed power supply voltage
*6 Vary with the impedance changes of the power supply including a DC reactor
*7 Vary with the impedance of the power supply
*8 When an EMC filter is embedded
*9 The maximum value of carrier frequency varies with the inverter capacity mode and operation status.
No comment |